4-5
EP750
Confidential
No
Step
Specification
Procedure
Photo
- Test Signal: 480P, 720P,
1080i @60Hz
- Test Pattern : Master
- PC Calibration
- Test Signal:1024x768@60Hz
- Test Pattern : White (Top)
Black (Bottom)
Note:
1. Calibration Pattern should
be in Full Screen Mode.
2. Please refer to 4-2. Guide to
Entering Service Mode and
Facotry Reset for entering
Service Mode.
3. Choose and access Video
Calibration & PC Calibration
for correction in Service
Mode. Choose “Exit” to
leave the Service Mode
after all.
9
Dead
Pixel
(Bright
pixel)
Cannot accept
any bright pixel
- Test Pattern : Full Black
Dead
Pixel
(Dark
pixel)
The numbers
of dead pixel
should be small
-
er or amount to
6 pixel.
- Test Pattern : Full White
0
Blemish
(Bright)
The bright blem
-
ish cannot be
accepted if the
problem appear
with Gary 30
pattern
- Test Pattern :
Full Black /
Gray 30
Blemish
(Dark)
The dark blem
-
ish cannot be
accepted if the
problem appear
with Blue 60
pattern.
- Test Pattern : Full
white / Blue 60