background image

LTCLHP

 | instruction manual

4

v 1.1

+

-

MULTI-TURN 

TRIMMER

2. Instructions for use

2.1 Operation options

LTCLHP telecentric illuminators integrate LTSCHP modules as light sources. 

LTSCHP LED modules can be operated in two ways: 

• 

standard

 usage option: through the built-in electronics 

• 

direct LED control

 usage option

2.1.1 STANDARD usage option (LED control through built-in electronics)

Only continuous mode (constant current) is allowed. 

Connection

Connect the black and brown cables to your +12 / +24 V power supply.

Light intensity adjustment

The built-in multi-turn trimmer allows to control the light (LED forward current) intensity 

with a very high degree of precision: you can bring the current intensity from minimum to 

maximum with 21 full turns of the adjustment screw. Simply remove the protective cap and  

rotate 

counter-clockwise

 the adjustment screw to increase light intensity and vice versa. 

black

 cable to 

ground

brown

 cable to 

power supply

 (+12 / +24 V)

Summary of Contents for LTCLHP series

Page 1: ...LTCLHP series Telecentric HP illuminators Instructions manual v 1 1 www opto engineering com...

Page 2: ...of contents 1 Product overview pag 3 2 Instructions for use pag 4 2 1 Operation options pag 4 2 2 LED source axial position pag 5 2 3 How to replace the LTSCHP module pag 6 2 4 How to replace the LED...

Page 3: ...telecentric lenses LTCLHP telecentric illuminators offer higher edge contrast when compared to diffused back light illuminators and therefore higher measurement accuracy This type of illumination is...

Page 4: ...nics Only continuous mode constant current is allowed Connection Connect the black and brown cables to your 12 24 V power supply Light intensity adjustment The built in multi turn trimmer allows to co...

Page 5: ...multi turn trimmer Connection Connect the black and blue cables as shown below remove the LED anode protective cover 2 2 LED source axial position LED axial position is an important operational parame...

Page 6: ...operational parameter make sure to follow the instructions in the next section to obtain optimal illumination homogeneity LTSCHP module LED centering tool to easily position and center LED1W x light s...

Page 7: ...1 4 LTCLHP056 R red 630 nm 2 0 2 LTCLHP056 G green 520 nm 0 5 1 LTCLHP056 B blue 460 nm 1 0 1 4 LTCLHP056 W white 0 5 1 1 4 LTCLHP064 R red 630 nm 2 0 2 LTCLHP064 G green 520 nm 0 0 LTCLHP064 B blue...

Page 8: ...thermal energy across the metal to metal interface we suggest to use grease with thermal conductivity greater than 0 765W mK Use the screws with the appropriate length according to the presence of int...

Page 9: ...e 2 4 1 Replacement instructions Follow these steps to properly replace LED1W source 1 5 2 6 3 4 Turn off LTCLHP and disconnect the power cable Unscrew the LTSCHP module from the LTCLHP illuminator Re...

Page 10: ...11 02 Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement CEI EN 61000 4 3 2007 04 CEI EN 61000 4 3 A1 2009 01...

Page 11: ...E phone 49 0 89 18930918 de opto engineering com Opto Engineering USA 11261 Richmond Ave Ste G 108 Houston TX 77082 phone 1 832 2129391 us opto engineering com ASIA Opto Engineering Europe headquarter...

Reviews: