Product introduction

 

A  comparison  microscope  is  a  new  type  of  microscope  that  uses  a  set  of  eyepieces  to 

simultaneously observe the left and right object fields of view, and uses the methods of field 

cutting, docking, and overlapping to compare two (or more than two) objects. The instrument 

has  clear  imaging  and  high  resolution,  and  can  accurately  identify  the  subtle  differences 

between the objects being compared. WBY-18C has superior optical performance, complete 

comparison functions, and can meet the needs of comparison work in different occasions, so it 

has  a  wide  range of  applications.  This  product  is  an  ideal  instrument  for  the  public  security, 

procuratorate,  courts  and  colleges  to  compare  and  detect  bullets,  tool  marks,  fingerprints, 

seals, words, patterns, currency, etc. It is also suitable for electronics, biochemistry, agriculture, 

archaeology,  banking,  All  industries  and  departments  that  require  comparative  detection  or 

identification of objects, such as customs. 

二、

Basic parameters 

1.

 

Left or right single field of view, overlapping field of view and smooth field of view can be 

divided  and  docked  observation,  and  there  is  a  diaphragm-type  ridge  line  consistency 

adjustable device. 

2.

 

Objective lens: Five-speed vertical zoom parfocal objective lens 0.8X, 1.25X, 2X, 3.2X, 

4.8X fixed magnification zoom operation is reliable and obvious; 

3.

 

Stage:  manual  control,  the  adjustment  mechanism  is  stable  and  reliable,  with 

self-protection  function.  The  unilateral  movement  range  of  the  stage  Movement  range: 

X-axis 55mm, Y-axis 55mm, Z-axis 65mm; the horizontal linkage range of the left and right 

stages:  60mm,  the  coarse  movement  lifting  range:  80mm

Equipped  with  a  round  fixed 

carrier tray that can be rotated 360°

 

4.

 

Lighting system: Using the latest capacitive touch screen, strong light-reflecting halogen 

tungsten  lamps  and  high-power  LED  lamps can  be  used  for  independent  lighting,  or  two 

sets of light sources can be used at the same time. firm positioning; 

5.

 

The front camera can collect static data from the front; 

Summary of Contents for A18.1831

Page 1: ...A18 1831 Comparison Microscope Step Zoom 3 2 288x Instruction Manual ...

Page 2: ...e comparative detection or identification of objects such as customs 二 Basic parameters 1 Left or right single field of view overlapping field of view and smooth field of view can be divided and docked observation and there is a diaphragm type ridge line consistency adjustable device 2 Objective lens Five speed vertical zoom parfocal objective lens 0 8X 1 25X 2X 3 2X 4 8X fixed magnification zoom ...

Page 3: ...220V AC input 12V DC regulated input in line with national safety standards eyepiece System magnification field of view Eyepieces magnification field diameter photog raphy system camer a system Work distance mm objective bridge 10X 20X 3X 2 5X 0 8X 1 2X 9 6X φ28 19 2X φ17 1 92X 12X actual Deter minatio n 101 1 25X 15X φ18 30X φ11 2X 24X φ11 48X φ7 3 2X 36X φ7 77X φ4 5 4 8X 58X φ4 2 115X φ2 3 Descr...

Page 4: ...upply 2 light control panel 3 Linkage lift knob 4 Horizontal linkage knob 5 Table lift knob 6 LED lights 7 objective lens 8 magnification adjustment knob 9 Field of view adjustment handwheel 10 2 3 4 5 6 7 9 10 15 16 17 18 19 20 21 1 8 22 12 13 14 11 ...

Page 5: ...Then turn the left and right stage lift knobs 5 until the two images are equally clear If the ridge line split line in the field of view is not clear turn the eyepiece diopter circle to adjust the diopter 五 Function and Operation In order to obtain the best use effect of the instrument it is necessary to have a detailed understanding of the functions of each part of the instrument and master the a...

Page 6: ...plate on the left and right stage respectively observe the reticle through the eyepiece and adjust the focus to make the two reticle images The same is clear move the magnification correction plate so that the reticle is aligned accordingly If the magnifications of the two objective lenses are inconsistent the reticle in the inspection cannot be all aligned At this time rotate the magnification co...

Page 7: ...erver s eyes rotating the screw sleeve on the binocular lens barrel can adjust the diopter and the observer can adjust the diopter Both eyes can clearly see the thin and black comparative ridges 7 Application of polarized light optional coaxial light optional transmitted illumination optional to compare some objects and traces such as scratch marks using polarized light will get better results Ins...

Page 8: ...era viewfinder then you can take pictures 9 Use of the holder For example when observing the inspection materials such as document inspection you can directly place the paper on the stage for observation the trace inspection material cannot be placed directly on the worktable and a clamping device needs to be used The specific use is as follows Observing the rifling marks of the clip warhead Horiz...

Page 9: ...your hands If there is dust on the surface of the optical lens it can be blown off with a blower and the oil can be gently wiped off with a lens paper dipped in a small amount of xylene 3 The power supply must have a ground wire during installation 4 After power on check whether the fuse is in good condition the fuse is at the power input socket 5 Replacement of the spare lamp is shown in the figu...

Page 10: ...r 3 11 UV sheet 2 12 magnification reticle 2 13 Fuse 3A 1 14 Spare light cup 12V50W 2 2 15 coaxial light 2 16 polarizer 2 17 Analyzer 2 18 Power cord power box American 1 1 19 camera mount Canon or Nikon 1 20 Ridge line adjustment wrench short 1 21 CD 1 22 φ4 inside corner wrench 1 23 Plum blossoms short 1 24 LCD 1 25 0 4XAdditional objective lens 2 26 2XAdditional objective lens 2 27 Instrument a...

Page 11: ...10 注 Required accessories for option ...

Reviews: