background image

INTERFACES

TRADITIONAL

PC ADAPTER CARD

Form 468-010131

DATA

 

SHEET

page 3/6

Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com

Inside Sales: (800) 321-OPTO • Product Support: (800) TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • E-mail: [email protected]

Jumper Installation

Configuration for AC24AT and AC422AT

Before installing your adapter card, configure your board by selecting the appropriate address, interrupt, and

communications jumpers.

These adapter cards can be configured as COM1 through COM4.  Select which COM port is to be used based on the current

configuration of the COM ports in the host PC.  Refer to the following table for jumper settings for the various COM ports.

Compatibility

The AC422AT and AC24AT models use the same UART used in the AT model computers.
The RS-422/485 adapter cards are seen by the computer as a standard serial port and will pass the IBM Advanced

Diagnostics program if a loop-back connector is used.  The following is a diagram of a loop-back connector for use in
diagnosing the adapter card.

Loop-back Connector

AC24AT

 AC422AT

Address

IRQ

Group A

Jumpers Installed

IRQ

Jumpers

COM1

3F8 Hex

4

None

COM1

COM2

2F8 Hex

3

8

COM2

COM3

348 Hex

2

4,5,7

IRQ2

COM4

340 Hex

5

3,4,5,7

IRQ5

Summary of Contents for AC24AT

Page 1: ...isolation between the PC bus and the communications link The AC24AT is also transient protected features bi directional handshake lines for RTS and CTS and can drive up to 100 devices on a multidrop...

Page 2: ...5 3017 E mail sales opto22 com Specifications Dimensions Power Requirements 250 mA at 5 VDC 150 mA at 12 VDC 150 mA at 12 VDC Operating Temperature Range 0 C to 60 C 95 relative humidity non condensin...

Page 3: ...s COM1 through COM4 Select which COM port is to be used based on the current configuration of the COM ports in the host PC Refer to the following table for jumper settings for the various COM ports Co...

Page 4: ...When RTS is inactive the driver is disabled If Jumper B7 is installed jumpers B1 and B3 must also be installed These jumpers passively pull the transmit lines to OPTOMUX to the inactive state If the...

Page 5: ...When a jumper is not present the jumper value is high one With no address jumpers present the adapter card will be selected from address 3F8 to 3FF hex Addressed as COM1 You can set the adapter card...

Page 6: ...ommunications and therefore requires that the COM1 or COM2 interrupt jumpers be installed when doing communications using COM1 or COM2 from BASIC Group B and C Jumpers The figure below shows the norma...

Page 7: ...ions hardware data service plan and Web portal in one easy to use package Visit nvio opto22 com for moreinformation Opto 22 Software Opto22 sioProjectandFactoryFloor software suites provide full featu...

Reviews: