Optiview TRKPTZ -26NX User Manual Download Page 23

Auto Zooming Tracking Dome Camera User Manual 

 

22 

LOW LIGHT LIMIT 

Low light limit is the maximum duration, it is in fractions of a 

second,  that  electronic  shutter  will  remain  open  in  low  light 
conditions. The default setting is 1/50. 

Settings  include:1/2,  1/3,  1/6,  1/12,  1/25,  1/50,  1/75,  1/100, 

1/120, 1/150, 1/215, 1/300, 1/425, 1/600, 1/1000, 1/1250, 1/1750, 
1/2500, 1/3500, 1/6500, 1/10000. 

 

IRIS LEVEL 

Iris  level  is  the  lens  function  that  automatically  opens  and 

closes  the  iris  in  response  to  changing  light  conditions.  The 
default setting is F2.0. 

Settings  include:  F2.0,  F1.6  ,  F1.4,  Close,  F22,  F19,  F16, 

F14, F11, F 9.6, F8.0, F6.8, F5.6, F4.8, F4.0, F3.4, F2.8, F2.4. 

 

AGC LEVEL 

AGC(Automatic  Gain  Control)  automatically  adjusts  the 

amount  of  video  amplification  to  maintain  a  Full  1-volt 
peak-to-peak video signal output. The default setting is 0 dB. 

  Settings include: 0dB, 2 dB, 4 dB, 6dB, 8 dB, 10 dB, 12 dB, 

14 dB, 16 dB, 18 dB, 20 dB, 22 dB, 24 dB, 26 dB, 28 dB. 

 

BRIGHT LEVEL 

The default setting is 0 dB /F2.0.

 

Settings include: 0 dB /F2.0, 0 dB /F1.6, 0 dB /F1.4, 2 dB / 

F1.4, 4 dB / F1.4, 6 dB / F1.4, 8 dB / F1.4, 10 dB/ F1.4, 12 dB/ 
F1.4, 14 dB/ F1.4, 16 dB/ F1.4, 18 dB/ F1.4, 20 dB/ F1.4, 22 dB/ 
F1.4, 24 dB/ F1.4, 26 dB/ F1.4, 28 dB/ F1.4, Close, 0 dB /F22, 0 
dB /F19, 0 dB /F16, 0 dB /F14, 0 dB /F11, 0 dB /F9.0, 0 dB /F 8.0, 
0 dB /F6.8, 0 dB /F5.6, 0 dB /F4.8, 0 dB /F4.0, 0 dB /F3.4, 0 dB 
/F2.8, 0 dB /F2.4. 

 

NOTE:

  LOW  LIGHT  LIMIT,  IRIS  LEVEL,  AGC  LEVEL 

BRIGHT LEVEL can set only when 

AE MODE and LOW LIGHT 

MODE 

are set as Manual.

 

 
(

)  Figure  3.7B  PROGRAM  AE  MODE  settings  are  for 

MODEL TRKPTZ18XX and TRKPTZ26XX. 

 

AE MODE                               

Settings  include:  AUTO,  AU+IR1,  AU+IR2,  AU+DSS, 

Summary of Contents for TRKPTZ -26NX

Page 1: ...Auto Zooming Tracking Dome Cameras User Manual...

Page 2: ...Main Menu 15 3 2 Select Language 15 3 3 System Information 16 3 4 Display Setup 17 3 4 1 Display Setup 17 3 4 2 Label Position 18 3 5 Dome Settings 1 19 3 5 1 Dome Settings 1 19 3 5 2 Camera Settings...

Page 3: ...Setting 41 3 6 5 Windows Blanking 43 3 6 6 Set Windows 44 3 6 7 Edit Windows Location 45 3 6 8 Edit Windows Zoom 46 3 6 9 Heater Setting 47 3 6 10 Cruise Setting 48 3 6 11 Tracking Setting 49 3 6 12...

Page 4: ...e feature will define the activity when the dome parks Integrated design making it high reliability Auto panning function with 256 preset positions RS 485 data communication Low noise design With its...

Page 5: ...trolling command in accordance with its own Address Baud rate and Protocol 2 Object tracking The dome can be manually controlled from the control system by using the joystick on the controller to move...

Page 6: ...es current horizontal angle and title angle of pan tilt zoom and position parameters into the memory When necessary dome calls up these parameters and adjusts Pan Tilt Zoom accordingly so that the cam...

Page 7: ...the glass with water drop or dust Target moves too fast Target is too big such as wall Target is too dark or vague c Iris control System defaults AUTO IRIS Camera can adjust immediately according to...

Page 8: ...ject in the sensitive area is properly exposed 10 Day and Night Function The IR cut filter of camera module inside the dome can be removed by sending special command so that the camera can change from...

Page 9: ...has four alarm inputs which can be programmed as high medium or low priority When an alarm is received an input signal to the dome triggers the user defined action go to preset run pattern etc program...

Page 10: ...e All other parts of the tilt area of the scene will be blanked NOTE Be the same with only the model of TRKPTZ 18NX TRKPTZ 26NX TRKPTZ 18NX TRKPTZ 26NX 20 Auto tracking Revolutionary motion tracking t...

Page 11: ...NTSC Image Sensor inch color CCD Horizontal Resolution 480 TVL Video Out 1 0 0 2VP P P T Speed Pan 0 05 240 sec Tilt 0 03 160 sec S N Ratio 50DB Sensitivity 1Lux 0 1Lux 0 01Lux 1Lux 0 1Lux 0 01Lux IR...

Page 12: ...to Cruise Auto switch from 1 to 30 preset position sequentially Patterns 4 Zone 8 Alarm input 4 Alarm output 2 Windows blanking 8 Interface RS 485 Baud Rate 1200bps 2400bps 4800bps 9600bps 19200bps Ad...

Page 13: ...device 1 Dome Self testing after Powered up After powered up the dome will conduct reset procedure In this procedure the dome firstly pans to the default horizontal origin point and finally tilts to...

Page 14: ...sted in Presets 2 in stead 5 Zoom You can press IN or OUT key continuously or revolve the joystick to get desired zooming times 6 Focus press FAR or NEAR key 7 Iris Press OPEN or CLOSE key Section 3 M...

Page 15: ...1 ADDR 0 This information will remain on the monitor until dome operation begins Please refer to the following pages for more about how to operate and program the camera Access main menu preset 95 Pl...

Page 16: ...anguage The language for the on screen menus is selectable Available languages include English and Chinese The factory default language is English Changing the display language 1 In main menu move the...

Page 17: ...menu shown as Fig 3 2 Figure 3 2 SYSTEM INFORMATION The system information screen shows dome language protocol and other configuration information System information settings shown are not changeable...

Page 18: ...d on the monitor The following labels are available PRESET LABEL Identifying preset ZONE LABEL Identifying zone ZOOM Identifying zooming times AZIMUTH ELEVATION Amount of pan from 0 and the amount of...

Page 19: ...shows when activated 3 4 2 Label Position Labels can be placed anywhere on the monitor This feature enables you to customize the place of labels on monitor screen Figure 3 4 Label Position To set a la...

Page 20: ...select DOME SETTING 1 press Open to enter the dome setting1 menu shown as Fig3 5 Figure 3 5 Dome settings 1 3 5 2 Camera Settings Move joystick to select CAMERA press Open to enter the camera menu sho...

Page 21: ...ter of the picture to adjust the iris If there is a bright light source outside this area it will change to white The camera will adjust the iris so that the object in the sensitive area is properly e...

Page 22: ...for models named TRKPTZ22XX and TRKPTZ23XXPNT Figure 3 7A PROGRAM AE MODE setting for models named TRKPTZ18XX and TRKPTZ26XX AE MODE Settings include AUTO MANUAL SHUTTER IRIS and BRIGHT LOW LIGHT MOD...

Page 23: ...omatically adjusts the amount of video amplification to maintain a Full 1 volt peak to peak video signal output The default setting is 0 dB Settings include 0dB 2 dB 4 dB 6dB 8 dB 10 dB 12 dB 14 dB 16...

Page 24: ...VEL Iris level is the lens function that automatically opens and closes the iris in response to changing light conditions The default setting is F1 6 Settings include F1 6 F2 2 F3 2 F4 4 F6 4 F8 8 F12...

Page 25: ...for the models named TRKPTZ22XX and TRKPTZ23XX AUTO IRIS Auto iris is the lens function that automatically opens and OTHERS IR CUT FILTER AUTO IR CUT FILTER COLOUR AUTO IRIS ON SHARPNESS ON SHARPNESS...

Page 26: ...it pans or tilts more than 15 degrees AUTO SHARPNESS Auto sharpness enhances picture details by increasing the aperture gain of the camera and sharpening the edges in the picture There are two settin...

Page 27: ...y Afterwards the dome camera starts moving upward even you still hold joystick in the down position Once you let go of the joystick after the dome rotates joystick control returns to normal operation...

Page 28: ...l pan mode The pan speed will not depend on the zooming times PARK TIME This feature enables the dome to operate a specified activity scan preset or pattern after a programmed time of idleness Park ti...

Page 29: ...ht to define an area The dome reverses direction frame scanning when a limit stop is reached To set scan stops 1 Move joystick to position the cursor beside set scan stops 2 Press iris Open 3 Follow t...

Page 30: ...n the set Azimuth Zero point To program azimuth zero 1 Move joystick to position the cursor beside set azimuth zero 2 Press iris Open 3 Follow the directions displayed on the monitor CLEAR AZIMUTH ZER...

Page 31: ...rame scan operation PRESET 1 Dome goes to preset 1 PRESET 8 Dome goes to preset 8 PATTERN 1 Dome runs pattern 1 PATTERN 2 Dome runs pattern 2 PATTERN 3 Dome runs pattern 3 PATTERN 4 Dome runs pattern...

Page 32: ...Move joystick to position the cursor beside a character Press iris Open to confirm selection To clear a character position the cursor beside BPE and then press iris Open d After the label is inputted...

Page 33: ...s iris Open c Follow the direction displayed on the monitor 3 5 6 Patterns Setting Use stick to select patterns Open to enter the patterns menu shown as Fig3 13 Figure 3 13 PATTERNS PROGRAME PATTERN A...

Page 34: ...ining storage percentage will be displayed on the screen This is the amount of memory available to program the remaining patterns CLEAR PATTERN 1 Move joystick to position the cursor beside CLEAR PATT...

Page 35: ...ion the cursor beside EDIT ZONE 4 Press iris Open The Zone programming window will show on the monitor 5 Follow the directions displayed on the monitor After the left stops and right limit stops are s...

Page 36: ...putted move the cursor to CN then press iris Open to cancel and return to the Preset menu To clear a zone 1 Move joystick to position the cursor beside CLEAR ZONE 2 Press iris Open Follow the instruct...

Page 37: ...please refer to the PATTERNS section RESTORE FACTORY DEFAULTS This is to restore leaving factory s default settings 3 5 9 Presets Number This is to set the dome s preset number 3 6 Dome Settings 2 Men...

Page 38: ...or low priority When an alarm is received the inputted signal to the dome triggers the user defined action go to preset run pattern etc programmed for the alarm There are three alarm settings ALARM NU...

Page 39: ...llow below steps to program alarm settings Select alarm number 1 a Move joystick to position the cursor the cursor beside ALARM NUMBER b Press iris Open c Move the joystick up or down to view selectio...

Page 40: ...NE No action when alarm is triggered PRESET Dome goes to the preset that is the same as the alarm number E g preset 1 will go to Alarm 1 PATTERN 1 Dome runs pattern 1 when alarm is triggered PATTERN 2...

Page 41: ...ed 1 An alarm action will close AUX 1 2 AN alarm action will close AUX 2 4 Press iris Open to confirm selection Set alarm contact 1 Move joystick to position the cursor beside ALARM CONTACT 2 Press ir...

Page 42: ...1 command from the controller will place a ground at the output of AUX 2 to operate the device that is connected to it Setting include 0 30secs An AUX 2 command from the controller will place a ground...

Page 43: ...tick to position the cursor beside a number Press iris Open to confirm selection 2 When password is inputted move the cursor to ENTER and press iris Open comes to the PLEASE INPUT NEW PASSWORED 3 Inpu...

Page 44: ...t in size according to zoom times Style The dome has two styles for window blanking GRAY and SMEAR If style is set to gray the blanked area is covered with a solid gray window If smear is selected ima...

Page 45: ...40 25 92 50 5 65 50 35 92 60 5 75 60 45 92 70 5 85 70 55 92 80 5 95 80 70 92 3 6 6 Set Windows Move joystick to select SET WINDOWS then press Open to enter the set windows menu shown as Fig 3 24 Figur...

Page 46: ...rent windows blanking Operation 1 Move joystick to select a item 2 Press iris Open 3 Move joystick to select parameters 4 Press Open 3 6 7 Edit Windows Location Move joystick and move cursor to EDIT W...

Page 47: ...rom the zone center Move stick right zoom in left right from the zone center Move stick up zoom in up down from the zone center Move stick down zoom in up down from the zone center 5 After the zone is...

Page 48: ...TING press Open to enter the following menu Figure 3 28 Figure 3 28 HEATER SETTING HEATER DISPLAY Heater display shows heater state ON Screen will display heater state OFF Screen will not display heat...

Page 49: ...m the menu shown in Fig3 17 move joystick to select CRUISE SETTING press Open to enter the following menu Fig 3 29 CRUISE Dwell Time the lasting time of preset from 5 250 seconds Preset List parameter...

Page 50: ...for cruising 0 for not cruising Operations 1 From the menu in Fig3 21 select relative item of 1234567890 with the joystick 2 Press Open and select a specific parameter Select options with joystick 3...

Page 51: ...cking stop tracking AUTO ZOOMING The dome will auto zoom in out according to the size and distance of the object Parameters can be ON OFF WAIT TIME S When the tracking object is lost the interval of t...

Page 52: ...r setting of the current boundary LEFT LIMT set the left tracking boundary RIGHT LIMT set the right tracking boundary UP LIMT set the up tracking boundary DOWN LIMT set the down tracking boundary Oper...

Page 53: ...ar current dome label Press Open to enter the menu and then operate with instructions 3 8 Other Functions RESET CAMERA If the camera does not operate or if you close camera s control cycle camera powe...

Reviews: