OPS70
Simple Install
Guide
Rev. 1.1
OPS70_Simple_Install_v1-1.indd
©2018 Procam Controls, Inc. All Rights Reserved
Access manuals, spec sheets and additional educationalmaterials for foodservice water treatment at our website.
www.optipurewater.com
Page 1: ...uide Rev 1 1 OPS70_Simple_Install_v1 1 indd 2018 Procam Controls Inc All Rights Reserved Access manuals spec sheets and additional educational materials for foodservice water treatment at our website...
Page 2: ...ing conditions 1 Altitude up to 2000 m 2 Ambient Temperature of 40 105 F 5 40 C 3 Maximum Relative Humidity 80 at 88 F 31 C 4 Installation Category II 5 Pollution Degree II 6 Indoor use only protect f...
Page 3: ...A drain should be located within 10 feet of the system Drain must allow a minimum flow of 2 gals min Compliance with most local plumbing codes requires installation of an approved air gap in the drain...
Page 4: ...ximize water pressure and flow Cut tubing to an efficient length using a tubing cutter or sharp blade Do not cut with wire crimpers or dikes When routing and securing tubing avoid loops or kinks Membr...
Page 5: ...and Bypass Assembly 3 8 red as shown below Step 1 Attach the system with 2 screws user supplied through the attachment keyholes shown below Use anchors or attach directly to studs Be sure to allow at...
Page 6: ...ubing coming from the lower left part of the Permeate Pump Attention Warranty will be void if this step is not performed properly Step 3 Insert and lock the CTO Q10 Cartridge into the Pre Filter Head...
Page 7: ...ap available part number 164 89905 Step 5a Install the Feedwater Adapter from the installation kit into the user supplied 1 2 Feedwater Supply Valve Do not over tighten Step 5b Connect a piece of 3 8...
Page 8: ...he remaining connection at the Tank Tee is the Optimized Water Outlet Insert the barbed end of the connector fitting into the 1 2 gray hose and secure with clamp Insert into the Tank Tee as shown This...
Page 9: ...sure Tank Valve is CLOSED Step 10 Open the Feed Valve Allow water to flow to drain until all air is purged from the system Close the Feed Valve after flushing Note During normal operation the water fl...
Page 10: ...ent If used insert the barbed end of the 3 4 GHT connector supplied into the 1 2 gray hose and secure clamp Connect ONLY to the treated steam water connection at the equipment Do not connect to the dr...
Page 11: ...r supply to downstream equipment is immediately needed the storage tank can be quickly filled Step 13 Simply OPEN the Bypass Valve and un filtered water will flow directly into the storage tank When t...
Page 12: ...When finished using equipment return the Valve to the CLOSED position DO NOT leave the system in bypass mode for prolonged periods of time IMPORTANT Leaving the system in bypass could cause damage to...