![Optimum Optiturn TU 2506 Operating Manual Download Page 146](http://html.mh-extra.com/html/optimum/optiturn-tu-2506/optiturn-tu-2506_operating-manual_1643046146.webp)
OPTIMUM
M A S C H I N E N - G E R M A N Y
Maintenance
Version 1.0.1 2014-05-16
Page 146
Original operating instructions
TU2506 | TU2506V | TU2807 | TU2807V
GB
4.1.2 Restarting
Before restarting run a safety check.
WARNING!
Before starting the lathe, you must check that there is no danger for persons and that
theis not damaged.
4.2
Inspection and maintenance
The type and level of wear depends to a large extent on the individual usage and operating
conditions. For this reason, all the intervals are only valid for the authorised conditions.
Interval
Where?
What?
How?
Start of work,
after every
maintenance or
repair work
La
th
e
Start of work,
after every
maintenance or
repair work
La
th
e
Lubricating
Lubricate all slideways.
Slightly lubricate the change gears and lead screw with
lithium-based grease.
Start of work,
after every
maintenance or
repair work
F
eed
gea
r
visual inspection
Check the oil level in the sight glass of the feed gear. It
must reach at least the centre of the sight glass.
If necessary, fill up to the reference mark with Mobilgear
627 or equivalent oil.
Img.4-1: Oil sight glass feed gear
Sight glass