27
To adapt the device to propane butane gas (PB/P) replace the
nozzles.
NOZZLE REPLACEMENT
– see Fig. XIV p. 16
To replace the nozzles:
1. Wait until the cooker cools down.
2. Remove the grate.
3. Remove the burner grates.
4. Unscrew the nozzles with the socket wrench no. 7 and repla
-
ce them with the ones suitable for the supply gas.
5. Place the burner grates and grate.
The burners do not require adjustment of primary air.
TYPICAL FAILURES
1. Spark igniter does not light up the gas or does not always li
-
ght it up
• Check if the cooker is connected to the mains.
• Clean and dry the burner components and the spark igniter.
• Check if the burner grates and caps are placed correctly.
2. The gas does not light up
• Check if the rubber hose, for supply with liquefied gas from
the cylinder, has not been crushed.
• Check if the main gas valve is open.
• Check if the gas cylinder is not empty.
• If a new cooker has been installed or the gas cylinder has
been replaced, repeat the lighting procedure until gas re
-
aches the burner.
• Check if the nozzle or flame openings in the burner are
not dirty or wet. If so, clean the nozzle opening with a pin
or needle. Use a brush to clean the burner openings. Then
dry all the parts.
3. Unstable flame
• Check if the burner parts are clean, dry and assembled cor
-
rectly.
If the above-mentioned advice does not solve the problem, con
-
tact the repair service. Do not attempt to repair the device on
your own! The device repair must be carried out only by a qu
-
alified person.
TECHNICAL PARAMETERS
Nominal voltage: 220 V – 240 V ~
Nominal frequency: 50/60 Hz
Maximum power consumption: 3521 W
The device is made to the I protection class
Burner output/gas consumption
Small
– 0,90 kW / 0,083 m
3
/h
Medium
– 1,65 kW / 0,149 m
3
/h
Big
– 2,20 kW / 0,208 m
3
/h
“Crown”
– 2,20 kW / 0,200 m
3
/h
Total gas consumption (burns) – 0,79 m
3
/h
Rated power consumption for particular parts:
Bottom heater – 1500 W
Top heater
– 2000 W
Grill
– 3500 W
Lamp
– 15 W
Spit motor
– 6 W
IP 20
Gas: G20 – 20 mbar
Category: II2E3B/P
PIN 1312BU5352
NOZZLE OUTPUT AND DIAMETER TABLE DEPENDING ON THE SUPPLY GAS TYPE
KIND OF GAS
BURNER
2E - G20 – 20 mbar
Small (5)
Medium (2; 3)
Big (4)
“Crown” (6)
Nozzle diameter [mm]
0,70
0,95
1,05
1,05
Burner output [kW]
0,90
1,65
2,20
2,20
KIND OF GAS
BURNER
3B/P-G30 37 mbar
Small (5)
Medium (2; 3)
Big (4)
“Crown” (6)
Nozzle diameter [mm]
0,50
0,65
0,75
0,75
Burner output [kW]
0,90
1,65
2,20
2,20
Summary of Contents for KGE-2090