MOUNTING INSTRUCTIONS 

     

Installation work, electrical wiring, mechanical maintenance and service must be done by 
qualified persons observing these instructions and in accordance with all applicable 
norms and standards. 
Each unit should be able to be disconnected according to the applied norms. If the unit 
is operated with additional controller, please consider the instructions of operation 
manual of controller

         

                                      

For all electrical connections there is no need to open the service door. All necessary 
connections are external and placed on the top of the unit

Power supply

The connection of the power supply is made on the top-external part of the air curtain.   
For an ambient air or water heated air curtain, only single phase 230V is needed. In case of an electric air 
curtain you must connect both single (230V) and three-phase (380V) in white connection box. 

Junction box for air only and water heated air 
curtains: Terminals L, N, (230V) and Earth.  

Junction box: terminals 2, 3, 4 (three-phase) for 
electrical heating and L, N, (230V) and Earth for 
fans. 

Control connector plate

To connect the controller there is a plate located on the top of the unit. The communication between the 
connector plate and the controller is digital through low-voltage cable with telephone plugs (RJ45). This 
cable, 20m length, is included with the air curtain. 

There are two types of connections: for water air curtains or only air with the telephone plugs and the green 
terminal plate for the electric valve (photo on left) and for electric air curtains with telephone plugs and the 
black connection box (photo on the right). 

Ceiling or wall mounting

Units are provided with 4 suspension points (M8) located on the top of the unit and also 4 threaded ones at 
the back of the unit (M8). This way there can be used ones or others depending on the installation (in-
ceilining mounting or wall-mounting). The exact situation of the fixation points is reflected in the curtain 
dimensions paragraph.  

A minimum of 150mm is recommended above de top of the unit to allow for wiring to power supply junction 
box, connectors plate and service. The curtains should be assembled in the ceiling using threaded rods, 
tensors, wall mounting brackets and other supports.  

The anchor should be managed according to each unit weight shown on the technical data page. 
Fixation angles can be supplied as described in the accessories paragraph.                                   

   

Summary of Contents for 1000 E

Page 1: ...ptima air curtains 04 SECURITY ADVICE SYMBOLS Attention Danger Safety advice Danger from electric current or high voltage Injuries risk Danger Do not step under hanging load Important Information AIRD...

Page 2: ...ected against overheat through thermal contacts and sensors and when the air curtain is switched off the fans continue working until the unit has cooled sufficiently Electrical power supply box and pl...

Page 3: ...tima 1500 P Optima 1500 E Power fan W 45 80 45 80 45 80 61 112 61 112 61 112 Current A 0 23 0 37 0 23 0 37 0 23 0 37 0 33 0 55 0 33 0 55 0 33 0 55 Voltage V 230 1 230 1 230 1 230 1 230 1 230 1 Speed r...

Page 4: ...ler there is a plate located on the top of the unit The communication between the connector plate and the controller is digital through low voltage cable with telephone plugs RJ45 This cable 20m lengt...

Page 5: ...second one the maximum power All electrical heat exchangers are protected against overheats They have a security that rearms automatic when the temperature it s over 50 C and another with manual rearm...

Page 6: ......

Page 7: ......

Page 8: ...led like this Connector RJ45 Phone cable 8 lines Connector RJ45 Tongue facing up Unfolded plane Tongue facing up Extensi n Adapter A Two female connectors to enlarges the cable between the air curtain...

Page 9: ...air discharge Memory Guarantees that in the event of a power shortage the selected speed will be maintained when the service is re established Telephone cable and digital communication Plug and play...

Page 10: ...ature increases up to 50 C the air curtain reacts increasing steep by steep the fan speed until the temperatures goes under 50 C If the air curtain reaches the maximum speed and the temperature inside...

Page 11: ...ust The cleaning can be easily done with a vacuum cleaner with a soft brush in order to avoid damages in the micro drilled grill The casing of the air curtain can be cleaned with a wet cloth and non a...

Page 12: ...et Make sure there is no tension in the curtain Wait until the fans are stationary Use only original spare parts To open the service door follow these steps 1 Remove the lateral cover 2 Lever smoothly...

Page 13: ...xle Fuse and PCB plate replacement Before the replacement advise people that there is work in progress Disconnect main supply make sure that the unit is without tension and that the fans are stationar...

Page 14: ...Before removing the screws that are fixed to the batteries we must Water coil replacement Close the shut off water valves of the building water circuit to the air curtain supply and return Open the se...

Page 15: ...d to remove the fixation screws of the inlet grill and the screws of the battery to disassemble the coil or heater and assemble the new heater following the same process in reverse order Then for both...

Page 16: ...expense The products that in our eyes have been inadequately used incorrectly manipulated improperly installed connected to different nominal tensions modified repaired by non authorized workers or t...

Reviews: