7

OPERATING INSTRUCTIONS

Power On/Off

 

● Turn on the power by pressing the power   button for 2 seconds. Once on, the 

scale will flash the voltage and then begin to auto-check and count down from 0-9  
sequentially before entering the weighing mode 
Note: Anything on the scale before powering on will automatically be tared out.

Zeroing

 

● The zero function is used only when the scale is empty and is not at gross zero due 

to material build up (such as a chain or rope)

 

● Pressing the ZERO   key will reset your scale to 0 

 

● Depending on what your manual zero range parameter is set to, you can zero out 

any number within your set selection, after that you will receive an error and will 
need to tare out the weight

Unit Selection

 

● To switch between measuring units (kg/lb) press the 2nd   key followed by the 

Zero   key to switch between units

Tare Function

 

● The Tare function is used when you only wish to see the current change in weight, 

not the entire amount of weight that is on the scale

 

● When the scale is in gross mode pressing the TARE   key will Tare the current 

weight on the scale and enter the net mode

 

● For example if you are using a chain add the chain to the scale, press tare and the 

display will show the tare symbol 

 and reset back to 0

 

● Add your product to the scale to weigh without the weight of the chain

 

● To exit Tare mode press the TARE key again to enter gross mode and you will see 

the total weight of the container and the product

Note: If you remove the chain the scale will show the minus weight of the chain

To use a pre-set tare weight

 

● Press 2nd   key, then press the TARE   key; the display should now show [00000]

 

● Using the arrow keys, input the tare weight value

 

● Press Hold 

 key to confirm and enter net weighing mode

Summary of Contents for OP-924

Page 1: ...optimascale com OP 924 CRANE SCALE USER S MANUAL OP 924A OP 924B Series...

Page 2: ...cautions 1 Preparations and Set Up 1 Features 2 Specifications 3 Power Supply 4 Displays 5 Display and Key Descriptions 6 Operating Instructions 7 98 Calibration 9 10 Scale Parameter Settings 11 Troub...

Page 3: ...re the weight is not over the Max capacity as it could damage the load cell inside Material that has a static electric charge could influence the weighing Discharge the static electricity of the sampl...

Page 4: ...ght Remote controller can capture peak weight at a distance of up to 100 feet 30m Wireless remote control has Hold function Low battery reminder Automatic power off power saving mode Technical Paramet...

Page 5: ...TERIOR DIMENSIONS A B C D E 5 88 8 50 5 75 2 91 15 16 17 13 HOOK DIMENSIONS A B C D E F G H I J K UP TO 2 000 LBS 2 55 0 60 1 35 2 65 3 25 0 90 0 90 2 92 0 96 3 15 4 92 OVER 2 000 LBS 2 55 0 60 1 35 2...

Page 6: ...ge resulted from left leakage of battery Once charged the battery should last for 45 hours An AC adapter should be provided with your scale Please use only the AC adapter provided to prevent damage to...

Page 7: ...5 OP 924A LED OP 924B LCD...

Page 8: ...in Gross weighing mode Battery Flashes red low battery Solid red charging Power Up Arrow Key Right Arrow Key Return Enter Enter 2nd Mode REMOTE KEY DESCRIPTIONS KEY Weighing Mode 2nd Mode Data Input...

Page 9: ...ss the 2nd key followed by the Zero key to switch between units Tare Function The Tare function is used when you only wish to see the current change in weight not the entire amount of weight that is o...

Page 10: ...nt to accumulate have been added to the scale Note Incase of a mistake Press DEL to clear the last accumulation data the display should show deL if not it will display nodeL Press F1 to total your wei...

Page 11: ...lbs FS 01 3 000 lb 0 5 lb 300 lbs 10 The display should show CALon Press HOLD to enter calibration mode or press to exit calibration mode 11 If calibration mode is entered then it should display LoAd0...

Page 12: ...ntrols the relationship to the weight in direct proportion 3 Use the arrow keys to modify the parameters then press HOLD to confirm 4 The display should now show EnD press HOLD to confirm 5 Note after...

Page 13: ...ically if no change within 90 min 10 Power Saving Mode idle mode idl 0 turn off power saving setting 10 turn off display if no change within 10 minutes 30 turn off display if no change within 30 minut...

Page 14: ...ons Error Reason Solution Err6 Exceed zero range Check the crane load U 628 Battery Power uuuuu Overload nnnnn Lower than the minimum value Reduce the weight 2nd 2nd mode weit foe combination key off...