OPTIKA MICROSCOPES B-150D Operation Manual Download Page 3

Page 3

This microscope is a scientific precision instrument designed to last for many years with a minimum of main

-

tenance. It is built to high optical and mechanical standards and to withstand daily use.
Optika reminds you that this manual contains important information on safety and maintenance, and that it 
must therefore be made accessible to the instrument users.
Optika declines any responsibility deriving from instrument uses that do not comply with this ma-nual.

  

Safety guidelines

This manual contains important information and warnings regarding safety about installation, use and 
maintenance of the microscope. Please read this manual carefully before using the equipment. To 
ensure safe use, the user must read and follow all instructions in this manual. OPTIKA products are 
designed for safe use in normal operating conditions. The equipment and accessories described in 
the manual are manufactured and tested according to industry standards for safety instrumentation 
laboratory. Misuse can cause personal injury or damage to the instrument. Keep this manual at hand 
close to the instrument, for an easy consultation. 

 

Electrical safety

Before connecting the power cord to wall outlet, ensure that your mains voltage for your region corre

-

sponds to the voltage supply of the instrument, and that the illuminator’s switch is in position OFF. The 
user must observe the safety regulations in force in his region. The instrument is equipped with CE sa

-

fety marking, in any case the user has full responsibility concerning the safe use of that instrument. 

 

Warning/Caution symbols used in this manual

The user should be aware of safety aspects when using the instrument. Warning or hazard symbols 
are shown below. These symbols are used in this manual. 

The instructions on this symbol to avoid possible severe personal injuries.

Warning of use; the incorrect operation on the instrument can cause damages to the 
person or instrument. 

Possibility of electric shock. 

Attention: high temperature surfaces. Avoid direct contact.  

Technical notes or usage tips.

SAFETY GUIDELINES

Summary of Contents for B-150D

Page 1: ...OPTIKA MICROSCOPES ITALY www optikamicroscopes com info optikamicroscopes com Ver 1 1 0 B 150D OPERATION MANUAL GUIDA UTENTE MANUAL DE INSTRUCCIONES...

Page 2: ...age 6 3 0 UNPACKING AND ASSEMBLY page 6 4 0 USING THE MICROSCOPE page 7 5 0 USING THE CAMERA page 8 6 0 RECHARGEABLE BATTERY B 150DMR B 150DBR MODELS page 10 7 0 MAINTENANCE page 10 8 0 TECHNICAL SPEC...

Page 3: ...industry standards for safety instrumentation laboratory Misuse can cause personal injury or damage to the instrument Keep this manual at hand close to the instrument for an easy consultation Electri...

Page 4: ...DIOPTRIC ADJUSTMENT RING BINOCULAR DIGITAL HEAD OBJECTIVE SLIDE CLAMP COARSE FOCUSING KNOB FINE FOCUSING KNOB BRIGHTNESS ADJUSTMENT ON OFF KNOB ON LEFT SIDE LED ILLUMINATOR IRIS DIAPHRAGM TRANSLATION...

Page 5: ...Page 5 1 0 DESCRIPTION MONOCULAR DIGITAL HEAD TENSION ADJUSTMENT KNOB POWER SUPPLY INPUT JACK REAR...

Page 6: ...arm and tighten the lock screw Insert the eyepieces into the eye tubes 3 3 Connect the provided power supply to the power supply input jack on the rear of the microscope 3 0 UNPACKING AND ASSEMBLY Con...

Page 7: ...the observation head by both hands and adjust the interpupillary distan ce by turning the two parts until one circle of light can be seen 4 5 Focus and diopter adjustment Rotate the coarse focusing k...

Page 8: ...lled from the CD Then ignore any message about Windows compatibility and select Continue Note do NOT cancel the installation 1 8 At the end of the identification process disconnect your Camera and try...

Page 9: ...y black 4 0 SELECT THE RIGHT DRIVERS It s very easy For B 150DM Monocular NOVEL H1C For B 150DB Binocular CAMERA X3 To use Optika Vision Lite you have to tell the Software which is the Driver by selec...

Page 10: ...t to use compressed air If that is not sufficient use a soft lint free piece of cloth with water and a mild detergent And as a final option use the piece of cloth moistened with a 3 7 mixture of ethan...

Page 11: ...9 0 RECOVERY AND RECYCLING Art 13 Dlsg 25 july 2005 N 151 According to directives 2002 95 EC 2002 96 EC and 2003 108 EC relating to the reduction in the use of hazardous substances in electrical and...

Page 12: ...g 16 3 0 DISIMBALLAGGIO E MONTAGGIO pag 16 4 0 UTILIZZO DEL MICROSCOPIO pag 17 5 0 UTILIZZO DELLA TELECAMERA pag 18 6 0 BATTERIA RICARICABILE MODELLI B 150DMR B 150DBR pag 20 7 0 MANUTENZIONE pag 20 8...

Page 13: ...aboratorio L utilizzo non corretto pu causare lesioni alla persona o danni allo strumento Mantenere questo manuale a portata di mano vicino allo strumento per una facile consultazione Precauzioni di s...

Page 14: ...OTTRICA TESTATA DIGITALE BINOCULARE OBIETTIVI PINZETTA MANOPOLA FUOCO MACROMETRICA MANOPOLA FUOCO MICROMETRICA REGOLAZIONE INTENSITA E ON OFF SUL LATO SINISTRO ILLUMINATORE LED DIAFRAMMA AD IRIDE MANO...

Page 15: ...Pagina 15 1 0 DESCRIZIONE TESTATA DI DIGITALE MONOCULARE MANOPOLA DI REGOLAZIONE DELLA TENSIONE JACK INGRESSO ALIMENTATORE RETRO...

Page 16: ...cio mediante l apposita vite di serrag gio Inserire gli oculari nei tubi porta oculari 3 3 Connettere l alimentatore fornito nella confezione al jack di ingresso posto sul retro 3 0 DISIMBALLAGGIO E M...

Page 17: ...testata fino ad ottenere la visione di un unico campo luminoso circolare afferrando le parti destra e sinistra della testata di osservazione con en trambe le mani 4 5 Regolazione della messa a fuoco e...

Page 18: ...lla incompatibilit con Windows e premete Continua Nota non annullare l installazione 1 8 Alla fine del processo togliete e poi inserite dopo alcuni secondi la telecamera se il vostro PC ha correttamen...

Page 19: ...lice Per B 150DM Monocular NOVEL HC1 Per B 150DB Binocular CAMERA X3 Con Optika Vision Lite per selezionare il driver cliccate l icona a forma di microscopio 5 0 OPTIKA VISION LITE UN PROGRAMMA COMPLE...

Page 20: ...zzare prima di tutto aria compressa Se questo non fosse sufficiente usare un panno non sfilacciato inumidito con acqua e un detergente delicato Come ultima opzione possibile usare un panno inumidito c...

Page 21: ...lative alla riduzione dell uso di sostanze pericolose nelle apparecchiature elet triche ed elettroniche nonch allo smaltimento dei rifiuti Il simbolo del cassonetto riportato sulla apparecchiatura o s...

Page 22: ...pag 26 3 0 DESEMBALAJE Y MONTAJE pag 26 4 0 UTILIZACI N DEL MICROSCOPIO pag 27 5 0 UTILIZACI N CAMERA pag 28 6 0 BATERIA RECARCABLE modelos B 150DMR B 150DBR pag 30 7 0 MANTENIMIENTO pag 30 8 0 ESPECI...

Page 23: ...uridad de instrumentaci n de laboratorio Una utilizaci n inadecuada podr a da ar el instrumento o provocar lesiones al usuario Mantener el presente manual cerca del instrumento para facilitar su consu...

Page 24: ...TIVOS PINZA DE SUJECI N DE MUESTRAS MANDO DE ENFOQUE MACROM TRICO MANDO DE ENFOQUE MICROM TRICO REGULACI N DE LA INTENSIDAD E INTERRUPTOR ON OFF EN EL LATERAL IZQUIEDO ILUMINADOR LED DIAFRAGMA IRIS MA...

Page 25: ...P gina 25 1 0 DESCRIPCI N CABEZAL DIGITAL MONOCULAR MANDO DE REGULACI N DE LA TENSI N CONECTOR JACK DE ALIMENTACI N REVERSO...

Page 26: ...rte superior del soporte utilizando el correspondiente tornillo de fijaci n Introducir los oculares en los tubos portaoculares 3 3 Conectar el alimentador suministrado con el microscopio al conector j...

Page 27: ...derecha del cabezal de observaci n y regular la distancia interpupilar de los portaoculares situados en el cabezal girando las dos partes hasta que no se observe un nico anillo de luz 4 5 Regulaci n...

Page 28: ...del proceso extraer la tele c mara y pasados unos segundos introducirla de nuevo Si se ha instalado correctamente el Driver no deber a aparecer ning n mensaje de error Si apareciese alg n mensaje de e...

Page 29: ...X3 Con Optika Vision Lite para seleccionar el driver buscar el icono con un microscopio 5 0 OPTIKA VISION LITE UN PROGRAMA COMPLETO PARA REALIZAR ME DICIONES Y DOCUMENTAR IM GENES Poner en marcha Opti...

Page 30: ...esidades pero con un m nimo de responsabilidad y seguridad 7 4 Limpieza de la pticas Si fuera necesario limpiar los componentes pticos utilizar en primer lugar aire comprimido Si no fuera suficiente l...

Page 31: ...03 108 CE relativas a la reducci n del uso de sustancias peligrosas en la instrumentaci n el ctrica y electr nica y a la eliminaci n de residuos El s mbolo del contenedor que se muestra en la instrume...

Page 32: ...TIKA S R L Via Rigla 30 Ponteranica BG ITALY Tel 39 035 571392 6 linee Telefax 39 035 571435 MAD Iberica Aparatos Cientificos c Puig i Pidemunt n 28 1 2 Pol Ind Pl d en Boet 08302 MATARO Barcelona Esp...