Step 5
Remove dust covers and connect two(2) duplex LC fibers to LC receptacles
of the Transmitter and Receiver modules, as shown in Fig. 8. Carefully
ensure the duplex LC connector is fully engaged.
Figure 7
– Connection of Two(2) Duplex LC Optical Fibers
Notice:
Please DO NOT look directly into the LC receptacles of Uplink
module, while they are powered on, although they are regulated strictly
enough to operate under the Laser Class 1, classified by CDRH/FDA for eye
safety.
Step 6
Connect an AC/DC power adapter to both Transmitter and Receiver modules
as your availability of AC outlets. You can find power indication LED lit on in
the both modules.
Figure 8
– Connection of AC/DC Power Adapter
Step 7
Power ON the PC and display or connected RS-232 devices. Ensure
“STATUS”, “OPTIC A” and “OPTIC B” indication LED lit ON, representing
secure connection of LC duplex fibers and all kinds of cables.
Tip 1:
If any status LED is not ON normally after all installation as guided in
the above, we recommend you to push
“RESET” button while all connections
are set and the Transmitter and Receiver
modules are powered in.
Tip 2:
Avoid “hot plugging” the Uplink as this is not recommended practice
with live digital voltages.
1-5 Installation
Troubleshooting
The display displays only black screen.
Check that all AC and DC plugs and jacks used by external power
supplies (both Opticis and others) are firmly connected.
Ensure that power LED lit ON.
Ensure that the Transmitter and Receiver modules connected
correctly to the PC and display, respectively.
Check if the PC and display are powered on and properly booted.
Reset the M5-2A2-TR using Reset button on Uplink and Downlink
modules.
Ensure video input is set at
“HDMI” if the display and video source
equipment are compatible with HDCP.
Re-boot up the system after reconnecting the LC optical fibers.
Screen is distorted or displays noises.
Check if the graphic resolution is properly set. Go to the display
properties and tap the settings.
Reset the M5-2A2 using Reset button on Transmitter and Receiver
modules.
Reset the system.
Power down, disconnect and reconnect the LC optical fiber or DC
power adaptors, and power up.
Maintenance
No special maintenance is required for this product. Ensure that this product
is stored or used in a benign environment free from liquid or dirt
contamination.
There are no user serviceable parts. Refer all service and repair issues to
Opticis or its authorized distributor.
Technical Support and Service
For commercial or general product support, contact your reseller. For
technical service, contact Opticis by email
website at
1-6 Troubleshooting, Maintenance, Technical Support