Manual No. 25-ULGPMU01-01 Series OPT Handheld
CCD Scanner
Page 34
Code 128, EAN 128 Settings
ZZ
Start/End
Program
Menu
-[[-
JF
Enable
EAN 128
only
-KG-
MO
Enable FNC2
concat-enation
-NP-
MP
Disable FNC2
concat-enation
-NQ-
%
OF
Disable
EAN 128
-PG-
%
OG
Enable
EAN 128
if possible
-PH-
Code 128 is a variable length symbology with a mandatory check digit and non-printable start/stop characters.
Supported characters include:
*
All 128 ASCII characters;
*
4 non data function characters;
*
4 code set selection characters;
*
3 start characters; and
*
1 stop character.
The check is calculated as the sum modulo 103 of the start character and the weighted values of the data and special
characters.
String format:
data (1 or more characters)
EAN 128
- In this mode, the Code 128 data is translated to the EAN 128 format. EAN 128 data starts with the FNC1
character and separates 2 data fields with the FNC1 character. The first FNC1 character is translated to ]C1, and the
second FNC1 character is translated to ASCII GS (hex 1D) character.
String format:
]C1
data
characters
<GS>
data
characters
Enable EAN 128 only
- In the mode, the decoded data characters are translated to the EAN 128 format. If the data
does not comply with the EAJ 128 format, then the label is rejected.
Enable EAN 128 if possible
- In this mode, the decoded data characters are translated to the EAN 128 format. If the
data does not comply with the EAN 128 format, then the label is transmitted as Code 128.