Opticon
OPI 4002
Specifications Manual
8
4.3. Ambient Light Immunity
Decoding performance is guaranteed when the range of illumination on a barcode
surface is between zero and the following values:
Incandescent light
to 10,000 lx
Fluorescent light
to 10,000 lx
Sunlight
to 100,000 lx
Direct light or specular reflection from a light source should be prevented from entering
the acceptance area.
5. Electrical
Specifications
5.1. Main Battery
The main battery is a lithium-ion secondary battery.
Nominal capacity: 1100 mAh
Nominal voltage: 3.6 V
Item Specifications Conditions
15 mA (max.)
When idle
250 mA (max.)
When scanning
Consumption
current
550 mA (typ.)
When charging
5.2. Battery Operating Time and Charging Time
Items Specifications
Conditions
Battery life
30 hours (min.)
1 scan / 5 s
Discharge and charge 300 times
Battery capacity 70% (1C charging)
Charging time
3 hours
Time necessary to fully charge an empty battery
Note:
Battery life may be shorter than specified above when the quality of the battery
pack is degraded.
Conditions
Ambient temperature: +25°
Symbology: 1-digit Code 39, PCS = 0.9, Resolution = 1.0 mm
Distance: 85 mm from the front edge of the scanner. (Single read)