Manual No. 25-NLB0045-01
Series NLB-9625/9645 Mini Laser Fixed Position Scanner
Page 32
Creating a Prefix and/or Suffix
The scanner can be programmed to transmit a prefix and/or suffix with the decoded data. A Prefix (or a Suffix)
is composed of up to 4 characters. The following steps are used to establish a Prefix that will be transmitted with
the bar code data:
1. Scan START to enter the Programming Mode.
2. Scan the bar code representing the symbology to which you wish to add a Prefix.
3. Scan the character(s) that will comprise the Prefix. Up to 4 numeric, alpha or control character(s)
may be used.
4. Scan STOP to exit the Programming Mode.
The same steps are used to establish a Suffix.
Setting Prefixes (Identifying the Symbology)
CONTINUED ON NEXT PAGE
Example
: To add the alpha character A as a Prefix
and B as a Suffix to UPC-A bar code data:
1) Scan START/END Programming Mode
2) Scan N1, representing a Prefix for UPC-A
3) Scan 0A, representing the alpha character A
4) Scan N6, representing a Suffix for UPC-A
5) Scan 0B, representing the alpha character B
6) Scan START/END Programming Mode
Computer
Command
Function
/Description
Bar Code
Command
(Z7)
START/END
Programming Menu
,Z7,
1Y
Clear all Prefixes
,1Y,
M0
UPC-A +2 or UPC-A +5
,M0,
M1
UPC-E +2 or UPC-E +5
,M1,
M2
EAN-13 +2 or EAN-13 +5
,M2,
M3
EAN-8 +2 or EAN-8 +5
,M3,