10. Environmental Specifications
10.1. Temperature
Operating Temperature
:
-
0 ~ 40
°C
Storage Temperature
: -40 ~ 70
°C
<Conditions>
Barcode
: 0.33 mm UPC/EAN specified in Section 9.1
Distance
: 65 mm from the front edge of the scanner
Angle
:
α
= 0°,
β
=
+
15°,
γ
= 0°
Reading test
: Read at intervals of 300 ms
10.2. Humidity
Operating Humidity
: 5 ~ 90% RH (no condensation, no frost)
Storage Humidity
: 5 ~ 90% RH (no condensation, no frost)
<Conditions>
Barcode
: 0.33 mm UPC/EAN specified in Section 9.1
Distance
: 65 mm from the front edge of the scanner
Angle
:
α
= 0°,
β
=
+
15°,
γ
= 0°
10.3. Ambient Light Immunity
Scanning performance is guaranteed when the illuminance on a barcode surface is between zero
and the following values:
Incandescent Light
: 10,000 lx
Fluorescent Light
: 10,000 lx
Sunlight
: 100,000 lx
<Conditions>
Barcode
: 0.33 mm UPCEAN specified in Section 9.1
Distance
: 130 mm from the front edge of the scanner
Angle
:
α
= 0°,
β
=
+
15°,
γ
= 0°
Figure 17: Ambient Light Immunity
Note: Scanning performance is guaranteed as far as the direct ambient light or specular reflection from the
illumination LED does not enter the light receiving section of the M-10.