Installation 

Important: Please keep the installation procedure below.  Improper or no 
operation may result if the start-up sequence is not correctly followed. 

 

Step 1 

Carefully unpack the contents of the shipping group. 

 

Step 2 

Plug the 5V power adapters to the power jack of the transmitter and receiver. 
Ensure the Power LED ON (Blue) and Status LED blinking slowly (Blue).

 

 

Step 3 

Please,  check  if  the  maximum  resolution  of  the  display  is  WQXGA 
(2560x1200).  Otherwise, follow the instructions for 

Self-EDID  Programming 

Procedure

 on page 1-5. 

 

Step 4 

Connect two (2) LC optical fibers between the transmitter and the receiver 
and each fiber channel shall be connected as 1 to 1 and 2 to 2 carefully and 
ensure the duplex connectors are fully engaged.  

 

Figure 2 

– Fiber numbering and Status LED position on a label 

 

 

 

 

 

 

1-3 Installation

 

Step 5 

Plug the transmitter to the DVI receptacle of the DVI source such as PC and the 
receiver to the DVI receptacle of the display as shown in figure 3.  

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3 

– Connection of optical fiber 

 

Note1:

 The maximum extension length by multi-mode fiber is 500 meters. 

Note2:

 Be recommended NOT to use any intermediate cable or adapter 

between them to avoid undesirable performance degradation. 

 

Step 6 

Make the PC and the display power ON. And ensure that the Status LED in 
transmitter and receiver turn on. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1-4 Installation

 

Tw

o (2)

 O

ptical 

Fiber

DDFX-100

Tx

DDFX-100

Rx