background image

 

OPTICAL SYSTEMS DESIGN 

 

DOC ID: 10117602 

OSD2258 QUICK START GUIDE

 

 

PAGE 9  

 

7

 

LED Indicators 

 

TABLE 4: LED FUNCTION 

LED 

Function 

Redundant 

Power 1 and 2 

Off 

Power is Not Applied to Corresponding Input 

Green 

Power Connected to Corresponding Input 

Power 

Off 

Unit is Off 

Green 

Unit is Powered On 

Ring 

Off 

Non-Ring Mode (SW6 On) 

Green 

Redundant Ring 

Amber 

Bus 

Green/Amber 

Initializing 

Link (speed) 

Copper Port 1-8 

Off 

10Mb or No Link 

Blink Amber 

100Mb 

Amber 

1Gb 

Act Copper Port 

1-8 

Off 

No Connection/No Activity 

Green 

Link Established 

Blink 

Activity 

SFP Ports 9-10 

Off 

No Link Established 

Blink 

SFP Link OK/Activity 

 
 

8

 

Fitting SFP Connectors 

 

Care should be taken when inserting/removing the SFP connectors from the SFP port as SFP modules 
are Electrostatic (ES) sensitive and Electrostatic Discharge (ESD) precautions should be taken when 
installing. Ensure that the SFP is fully engaged and latched into position. 
 

Inserting SFP

 – Ensure that the SFP lever is in the locked position and insert into appropriate SFP 

port. Gently push the SFP until it locks into place. Remove plastic/rubber dust cap and fit appropriate 
fiber cable. 
 

Removing SFP

 – Remove fiber connector. Pull the SFP lever down to unlock SFP from housing. 

Using the lever, gently pull the SFP out. 
 
 
 
 
 

Fiber SFP

 

 
 
 
 
 
 
 
 

FIGURE 6: FITTING/REMOVING SFP CONNECTORS 

 

 

Inserting 

SFP 

Removing 

SFP 

Summary of Contents for OSD2258

Page 1: ...Quick Start Guide OSD2258 10 PORT REDUNDANT RING GIGABIT ETHERNET SWITCH...

Page 2: ......

Page 3: ...P CONFIGURATION 11 10 GUI OVERVIEW 12 10 1 DEFAULT SETTING 12 10 2 LOG INTO THE SWITCH 12 10 3 IP CONFIGURATION 13 10 4 VLAN 13 11 RESET TO FACTORY DEFAULT 13 12 WARRANTY 14 12 1 WARRANTY PERIOD 14 12...

Page 4: ...ducts are installed should be restricted in access to trained service personnel only and appropriate warning signs posted in the work area All laser apertures should be covered by protective covers wh...

Page 5: ...2 OSD2258 QUICK START GUIDE PAGE 5 3 OSD2258 FRONT AND REAR PANELS 3 1 FRONT PANEL FIGURE 1 FRONT PANEL Power LED Ring LED Activity LED x 8 Link LED x 10 Ports 1 4 RJ45 Copper Ports Ports 5 8 RJ45 Cop...

Page 6: ...58 QUICK START GUIDE PAGE 6 3 2 TOP PANEL FIGURE 2 TOP PANEL 3 3 BOTTOM PANEL FIGURE 3 BOTTOM PANEL Power 1 LED Power 2 LED Dual Redundant Power Input Alarm Output 1 2 8 Way Configuration Switches Min...

Page 7: ...10 to 36VDC or 22 to 28VAC 10VA 5 Alarm Connections The OSD2258 has two monitoring alarm outputs 1 Ring to Bus Alarm and 2 Temperature Alarm The alarm connections and conditions for alarm outputs are...

Page 8: ...MBER DESCRIPTION FUNCTION SWITCH POSITION 1 GUI Mode Enable WebGUI On Disable WebGUI Off 2 Not Used On Off 3 Not Used On Off 4 High PoE 60W per port On Auto Mode Off 5 Not Used On Off 6 Ring Non Ring...

Page 9: ...Link Established Blink SFP Link OK Activity 8 Fitting SFP Connectors Care should be taken when inserting removing the SFP connectors from the SFP port as SFP modules are Electrostatic ES sensitive an...

Page 10: ...SYSTEMS DESIGN DOC ID 10117602 OSD2258 QUICK START GUIDE PAGE 10 9 CLI OVERVIEW 9 1 CONNECT TO CLI The Silicon Laboratories CP210x VCP Drivers is needed to be installed on the PC before connecting the...

Page 11: ...ole Port on UUT to PC with USB cable Type A to Type B 2 Using HyperTerminal to set up the following parameters Baud Rate 57600 Data Bits 8 Parity None Stop Bits 1 Flow Control None 3 Check the link by...

Page 12: ...2 LOG INTO THE SWITCH Connect a switch port to a PC Change the PC s network IP address to connect to the switch i e 192 168 0 2 In a web browser enter the URL default 192 168 0 99 The GUI should now h...

Page 13: ...Click Save button to save changes Earlier versions will have the VLAN function permanently enabled 11 Reset to Factory Default Changes made to settings IP VLAN etc through the GUI are saved when in de...

Page 14: ...ve for all repairs 12 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 12 2 2 OUT OF WARRANTY REPAIRS OSD reserves th...

Page 15: ...OPTICAL SYSTEMS DESIGN DOC ID 10117602 OSD2258 QUICK START GUIDE PAGE 15...

Page 16: ...y Ltd 7 1 Vuko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY...

Page 17: ...OPTICAL SYSTEMS DESIGN DOC ID 10117602 OSD2258 QUICK START GUIDE PAGE 17 Printed in Australia...

Reviews: