4.

 

WARRANTY 

 

Thank you for purchasing equipment designed, manufactured and serviced by Optical Systems Design 
(OSD). OSD warrants that at the time of shipment, its products are free from defects in material and 
workmanship and conforms to specifications. Our Warranty conditions are outlined below: 

 

4.1

 

WARRANTY PERIOD 

 
For warranty period, please call your local OSD distributor. 
 

4.2

 

ALL REPAIRS 

 
Optical Systems Design reserves the right to repair or replace faulty modules/units. Please obtain a 
“Return Material Authorisation” number form and number before returning goods. 
Goods must be returned to Optical Systems Design, Warriewood or its nominated authorised 
representative, for all repairs in adequate packing material. 
 
4.2.1

 

WARRANTY REPAIRS 

 
Return shipments to OSD shall be at customer's expense and freight back to the customer will be at 
OSD expense. 
 
4.2.2

 

OUT-OF-WARRANTY REPAIRS 

 
OSD reserves the right to repair or replace any faulty goods. Freight costs and insurance for both 
journeys are met by the user. All equipment repaired by OSD will have a 3 Month Warranty from the 
date of dispatch.   
 
4.2.3

 

SITE REPAIRS 

 
By agreement site repairs may be undertaken for which out of pocket, hotel and travel expenses will be 
charged. 
 
4.3

 

EXCLUSIONS 

 
This warranty does not apply to defects caused by unauthorised modifications, misuse, abuse or 
transport damage to the equipment. All modifications to OSD’s standard product will need written 
authorisation and will be charged at normal repair rates. All modifications are to be carried out by OSD 
Technicians. Warranty will lapse if unauthorised removal and/or tampering with serial number and/or 
repair labels occurs. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for OSD136

Page 1: ...OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM...

Page 2: ...OPTICAL SYSTEMS DESIGN DOC ID 10100110 OSD136 OPERATOR MANUAL Page 2 of 16...

Page 3: ...LS 12 2 2 6 INDICATORS 12 2 3 OPERATION 13 2 3 1 BLOCK DIAGRAM 13 3 MAINTENANCE 14 3 1 INTRODUCTION 14 3 2 EXTERNAL INSPECTION 14 3 3 ROUTINE MAINTENANCE 14 4 WARRANTY 15 4 1 WARRANTY PERIOD 15 4 2 AL...

Page 4: ...r handshake signals where distance electrical noise and or security considerations render conventional twisted pair RS232 links impractical While normally used as an RS232 modem the OSD136 can also be...

Page 5: ...ble for the OSD136 These options are identified in TABLE 1 below TABLE 1 PRODUCT OPTIONS ITEM DESCRIPTION OSD136 Fiber Optic RS32 Transceiver small module OSD136L Singlemode Fiber Optic RS232 Transcei...

Page 6: ...r 22dB for WA or WB single fiber variants Receiver Saturation 10dBm Optical Transmitter Wavelength 850nm for OSD136 and OSD136C WA 1310nm for OSD136L OSD136LC WA and OSD136C WB 1550nm for the OSD136LC...

Page 7: ...3V external power shown is where the 1 3mm power plug would be attached if an external OSD136PP power supply is used FIGURE 2 A SYNCHRONOUS DATA TRANSFER 2 3 15 17 24 4 5 8 20 6 1 7 9 21 12 2 3 15 17...

Page 8: ...6 1 7 9 21 12 2 3 15 17 24 4 5 8 20 6 1 21 7 9 12 Tx CH1 DATA Rx CH1 DATA Rx CH4 DATA Tx CH4 DATA Tx CH2 DATA Rx CH2 DATA Tx CH3 DATA Rx CH3 DATA CASE GND SIG QUAL SIG GND 9V POWER 5V POWER EXTERNAL P...

Page 9: ...This is a Class B product OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 2014 standard Class 1 The OSD136 is a Class 1 laser product PRECAUTIONS All service pe...

Page 10: ...KAGING OSD136 is available in three different packages All packages are shown in FIGURE 4 Dimensions in the pictures are in mm 55 44 15 12 5 93 6 3 a small module version b module version c 5T card ve...

Page 11: ...C may be supplied via pin 12 of the D connector In all cases the most negative side of the supply is connected to signal ground pin 7 of the 25 pin D connector FIGURE 5 POWER SOCKET CONNECTION DIAGRAM...

Page 12: ...with good optical input and Low 0 5V when the optical input is too low The optical fiber must be terminated by the appropriate optical connector Before connection inspect the end of the connectors to...

Page 13: ...E 8 below is a simple block diagram of the OSD136 FIGURE 8 BLOCK DIAGRAM D CONNECTOR 9 TO 12 V QUALITY SIGNAL DTR RTS TX CLOCK TX DATA DSR CTS RX CLOCK RX DATA INPUT EXTERNAL POWER 9 TO 12V 5V INDICAT...

Page 14: ...rtion of their support circuitry Some components within the unit are electrostatic sensitive and ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL INSPECTION Visua...

Page 15: ...adequate packing material 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserv...

Page 16: ...Optical Systems Design Pty Ltd 7 1 Vuko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email osdsales osd com au Web Site www osd com...

Reviews: