![opti-solar SP5000 Power-M User Manual Download Page 30](http://html1.mh-extra.com/html/opti-solar/sp5000-power-m/sp5000-power-m_user-manual_1641313030.webp)
28
Table 2: Inverter Mode Specifications
INVERTER MODEL
SP5000 Power-M
Rated Output Power
SP5000 Power-M/5KW
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
110/120Vac(L-N or L1-N-L2)
Output Frequency
60Hz or 50Hz
Peak Efficiency
90%
Overload Protection
5s@≥150% load; 10s@110%~150% load
Surge Capacity
2* rated power for 5 seconds
Nominal DC Input Voltage
48Vdc
Cold Start Voltage
46.0Vdc
Low DC Warning Voltage
@ load < 20%
44.0Vdc
@ 20% ≤ load < 50%
42.8Vdc
@ load ≥ 50%
40.4Vdc
Low DC Warning Return Voltage
@ load < 20%
46.0Vdc
@ 20% ≤ load < 50%
44.8Vdc
@ load ≥ 50%
42.4Vdc
Low DC Cut-off Voltage
@ load < 20%
42.0Vdc
@ 20% ≤ load < 50%
40.8Vdc
@ load ≥ 50%
38.4Vdc
High DC Recovery Voltage
58Vdc
High DC Cut-off Voltage
60Vdc
No Load Power Consumption
<100W
Table 3: Charging Mode Specifications
Utility Charging Mode
INVERTER MODEL
SP5000 Power-M
Charging Current (UPS)
@ Nominal Input Voltage
2A/10A/20A/30A/40A/50A/60A
Bulk Charging
Voltage
Flooded Battery
58.4Vdc
AGM / Gel Battery
56.4Vdc
Floating Charging Voltage
54Vdc
Overcharge Protection
60Vdc
Charging Algorithm
3-Step