38(1 1/2")
61(2 3/8"
)
267(10 1/2")
125(4 15/16")
36(1 7/16")
43(1 11/16")
7.5(5/16"
)
MANUFACTURER'S STATEMENT
DETECTION AREA
OUTER DIMENSIONS AND PART NAMES
5919221 OCT
2012
(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Width adjustment screws
(5) Depth angle adjustment screw
(6) Microwave sensitivity potentiometer
(7) Dipswitches
(8) Detection window
(9) Area adjustment tool
Model
Cover color
Mounting height
Detection area
Detection method
Depth angle
adjustment
Power supply
Power consumption
Operation indicator
Activation output
: X-ZONE
: Black
: 2.0 (6'6") to 3.5m (11'6")
: See
DETECTION AREA
: Active infrared reflection*1
Microwave doppler effect
: AIR area -6 to +6°
Microwave area +25 to +45°
: 12 to 24VAC ±10% (50 / 60 Hz)
12 to 30VDC ±10%
: < 2.5W (< 4VA at AC)
: See
Operation indicator table
: Form C relay
50V 0.3A Max.(Resistance load)
Safety output
: Form C relay
50V 0.3A Max.(Resistance load)
Output hold time
Response time
Operating humidity
IP rate
Weight
Accessories
: <1.0 sec.
: <0.3 sec.
Opetating temperature : -35 to +55°C (-31 to 131°F)
: <80%
: IP54
: 320g (11.2oz )
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3m (9'10")
1 Narrow lens
The specifications herein are subject to change without prior notice due to improvements.
NOTE
MANUFACTURER'S STATEMENT
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of the equipment.
Danger of electric shock
WARNING
CAUTION
NOTE
Disregard of the warning symbol can cause improper operation which may cause death
or serious injury.
Special attention is required to the section of this symbol.
Disregard of the caution symbol can cause improper operation which may cause injury of a
person or damage the object.
NOTE
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of
a person.The meanings of the symbols are as follows.
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door.
Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which
the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building
owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
The actual detection area may become smaller depending on the ambient light, the color / material of
the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than
50mm / sec. or faster than 1500mm / sec.
NOTE
[mm (inch)]
Operation indicator table
CAUTION
Risk of getting caught
Make sure to affix the mounting template as described in the above chart,
otherwise it can be dangerous since there may be no detection area around
the threshold. Install the sensor as low as possible on the header.
WARNING
Danger of electric shock
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain cover
(separately available) otherwise electric shock or breakdown of
the sensor may occur.
Before starting the procedure, make sure that the power is turned OFF.
When passing the cable through the hole, do not tear the shield
otherwise it may cause electric shock or breakdown of the sensor.
4
Wire the cable to the door controller as shown below.
1.Plug the connector.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See
ADJUSTMENTS 4. Dipswitch settings
)
Place the housing cover.
If wiring is to be exposed, break the knockout.
H : Height from the floor to the bottom of the header
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
WARNING
Danger of electric shock
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 seconds in order to enable the presence detection.
INSTALLATION
The following conditions are not suitable for sensor installation.
-Fog or exhaust emission around the door
-Wet floor
-Vibrating header or mounting surface
-Moving objects, steel plate, emergency lights or illumination in the detection area or in vicinity
-Highly reflecting floor or highly reflecting objects around the door
NOTE
X
H
Y
Sensor
Door
Header
Floor
SPECIFICATIONS
(1)
(4)
(5)
(8)
(6)
(9)
(3)
(2)
1. Affix the mounting template at the desired mounting position.
2. Drill two mounting holes of ø3.4mm (ø1/8”).
3. To pass the cable through the header, drill a wiring hole of ø8mm (ø5/16”).
4. Remove the mounting template.
5. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
Refer to the chart in below.
X-ZONE
1
2
3
4
AIR
Microwave
Mounting height : 2.2m(7'2")
Vertical adjustment : +35°
Sensitivity : H
Speed of detection object
: 50mm / sec.
Mounting height : 2.2m(7'2")
Angle adjustment : +6°
Sensitivity : M
: Emitting spots
: Detection area
: Emitting spots
(can be eliminated)
: Detection area
(Wide area)
: Detection area
(Narrow area)
1sec.
1sec.
Set-up
Stand-by (installation mode)
Stand-by (operation mode)
Sensor failure
Signal saturation
2nd row detection
Blue-zone (1st row) detection
*2
3rd row detection
Microwave detection
Status
Yellow blinking
Green
Fast green blinking
Slow green blinking
Yellow
Orange
Red
Operation indicator color
Red blinking
Blue
(7)
BLUE-ZONE
When dipswitch 15 is set to ON, the blue-zone area, that provides extra safety over the threshold, is activated.
In case the blue-zone function is not required, set dipswitch 15 to OFF.
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.
Blue-zone
(1st row)
2nd row
3rd row
Blue-zone
(1st row)
2nd row
3rd row
The chart shows the values at depth angle +6°
AIR emitting area
[m(feet,inch)]
A
C
B
G
H
I
0
1000
(3′3")
1000(3′3")
2000(6′6")
1000
(3′3")
2000
(6′6")
2000
(6′6")
Blue-zone(1st row)
2nd row
3rd row
D E
F
A
B
C
D
E
F
G
H
2.20 (7'2")
0.08 (3")
0.25 (10")
0.39 (1'3")
0.65 (2'2")
1.33 (4'4")
2.70 (8'10")
0.10 (4")
0.31 (1')
3.00 (9'10")
0.11 (4")
0.34 (1'1")
0.48(1'7")
0.80 (2'8")
0.53 (1'9")
0.89 (2'11")
1.63 (5'4")
1.81 (5'11")
2.50 (8'2")
0.09 (4")
0.28 (11")
0.44 (1'5")
0.74 (2'5")
1.51(4'11")
2.00 (6'6")
0.07(3")
0.06 (2")
0.074(3")
0.08 (3")
0.07 (3")
0.05(2")
0.23 (9")
0.35 (1'2")
0.59 (1'11")
1.21 (3'12")
2.05 (6'9")
2.51 (8'3")
2.79 (9'2")
2.32 (7'7")
1.86 (6'1")
I
2.78 (9'1")
3.40 (11'2") 3.79 (12'5")
3.50 (11'6")
0.12 (5")
0.39 (1'4")
0.61 (2')
1.38 (3'5")
2.11 (5'11")
0.09 (4")
3.25 (10'8")
4.42 (14'6")
3.15 (10'4")
2.52(8'3")
[mm(feet,inch)]
Maximum distance (Y)
X
2.00 (6' 6")
2.30 (7' 6") 2.50 (8' 2") 2.80 (9' 2")
0
No limit
0.05 (2")
0.13 (5")
0.13 (5")
0.14 (6")
0.10 (4")
0.11 (4")
0.12 (5")
0.12 (5")
0.12 (5")
0.15 (6")
0.10 (4”)
0.10 (4”)
0.11 (4")
0.11 (4")
0.20 (8")
-
0.09 (4”)
0.10 (4”)
0.10 (4”)
0.25 (10")
0.09 (4”)
0.30 (1')
-
-
H
0.13 (5")
-
-
-
-
0.09 (4")
[m (feet,inch)]
3.00 (9'10") 3.50 (11'6")
0.14 (6")
0.12 (5")
0.11 (4")
0.10 (4")
0.09 (4")
-
0
0
0
0
0
0
NOTE
Make sure not to mount the sensor lower than the bottom of header.
Mounting
surface
}
12 to 24VAC
10
%
12 to 30VDC 10%
Common (COM.)
Normally open (N.O.)
Normally closed (N.C.)
Common (COM.)
Normally open (N.O.)
Normally closed (N.C.)
Power supply
Safety output
Activation output 2
1
3
1.Grey
2.Grey
3.White
4.Yellow
5.Green
6.White stripe
7.Yellow stripe
8.Green stripe
Knockout
Knockout
*1 : Active infrared reflection has a presence detection function.
*2 : See
BLUE-ZONE