Model
Lens color
Detection method
Coverage
Mounting height
Detection speed
LED alarm indicator
Tamper alarm
Alarm output period
Warm-up period
Current consumption
Weight
Operating temperature
Environmental humidity
URX-P01
URX-P01WH : White
URX-P01BL : Black
Impulse Radio (Ultra Wide Band)
2.0 ~ 3.0 m (6.5 to 10 ft)
0.3 ~ 1.5 m/sec. (1 to 5 ft/sec.)
Red LED ON When detecting, Switchable ON/OFF
2 sec.
Power input
Approx. Under 10 sec.
12 VDC (9.6 to 14.4 VDC)
30 mA (max.) at 12 VDC
Approx. 85 g (2.99 oz)
-10˚C to +50˚C (+14˚F to +122˚F)
95% max.
N.C. (30 VDC, 0.1A max.)
9
DIMENSIONS
11
COMPLIANCE
NOTE This unit is designed to detect movement of an intruder and activate an
alarm control panel.
Being only a part of a complete system, we cannot accept responsibility
for any damages or other consequences resulting from an intrusion.
10
SPECIFICATIONS
Specifications and design are subject to change without prior notice.
10 m x 10 m (33 ft x 33 ft), 90˚ wide
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net/
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com/
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec/
WIRE GAUGE
12 VDC
14 VDC
AWG 22 (0.33 mm
2
)
AWG 20 (0.52 mm
2
)
AWG 18 (0.83 mm
2
)
Model
Color
Angle (Default)
Angle (Max. range)
Min. angle adjustment
Installation location
GB-41
White
0°
0°
±50°
15°
5°
2.5°
Wall, Ceiling
Horizontal
Vertical
Horizontal
Vertical
Horizontal
Vertical
Unit: mm (inch)
Alarm output
Gray
White
Green
Black
Red
Tamper
output
Alarm
output
Power
input
Spare
NC
COM
NC
COM (-)
(+)
- 2 -
FCC ID: Q54URXP01
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
5
BRACKET ADJUSTMENT
8
TERMINALS
6
SETTINGS
7
WALK TEST
Note>>
Adjust correctly detector range according to site condition.
Angle adjustment
lever
Adjustable
Lock
Power wire maximum length
(using one unit on a single wire)
1
Set LED ON.
LED
ON
LED
OFF
2
Conduct a walk test.
190 m
(620 ft)
300 m
(980 ft)
480 m
(1,570 ft)
420 m
(1,380 ft)
660 m
(2,170 ft)
1,050 m
(3,440 ft)
Terminals color
0 1
2
3
4
56
7
8
9
LED
ON
LED
OFF
LED switch
Range selector rotary switch
10m
Switch
detection
Range
1m 2m 3m 4m 5m 6m 7m 8m 9m
0
1
2
3
4
5
6
7
8
9
N.C. (30 VDC, 0.1A max.)
Lever position
15°
50°
50°
Detector specifications
Bracket specifications
Note>>
60 (2.36)
95 (3.74)
109 (4.29)
0 1
2
3
45
6
7
8
9
Adjust bracket angle vertically can
reduce the detection range.
Removing the bracket from the detector
1
Separate the main unit and
the back case.
2
Push the hook downward.
3
Pull the back case forward.
103 (4.06)
112 (4.41)
124 (4.88)
1.
2.
Note>>
Caution
Conduct a walk test outside of the room to check there is no area outside.
▪
Conduct a walk test at least once a year.
▪
To operate self-check function correctly, leave the detector ON for 5 minutes.