background image

Thank you very much for purchasing SS Checker TS-1000-D/ 
TS-1000SP-D.
All of this instruction manual must be read before operation of this  
SS Checker for safe and proper operation. 
This instruction manual should be kept for future reference such as 
maintenance.   

SS Checker

TS-1000-D/

TS-1000SP-D

Instruction 

Manual

WATER it 

The instruction manual is also available on the following website.

https://navi.optex.net/manual/05325/?lang=en

Summary of Contents for TS-1000-D

Page 1: ...efore operation of this SS Checker for safe and proper operation This instruction manual should be kept for future reference such as maintenance SS Checker TS 1000 D TS 1000SP D Instruction Manual WAT...

Page 2: ...r 1 Lifting lug 1 Hanging attachment 1 Cable protective cover 1 Cable tying band 5 Instruction manual this document If there are any missing or faulty items please contact our sales representative Ref...

Page 3: ...15 Output item selection 15 Upper lower limit of signal output range 16 7 Relay Setting 17 Alarm output setting 17 Maintenance output setting 18 Self Checking output setting 18 8 Calibration 19 Zero c...

Page 4: ...al 30 12 Troubleshooting 31 Error code list 31 13 Maintenance 33 Maintenance monthly 33 Periodic inspection every 3 months 33 Replacement of consumables 33 Calibration 34 Long term storage 34 Overhaul...

Page 5: ...nction observe the precautions for use without fail Do not use TS 1000 D TS 1000SP D except for measurement of water quality denotes Prohibited action and denotes Required action In the unlikely event...

Page 6: ...mild detergent solution and then wipe off moisture with a dry clean soft cloth Do not wipe the sensor with solvent such as Thinner It may cause failure 2UJDQLF 6ROYHQW 7KLQQHU HWF Avoid strong physic...

Page 7: ...7 2 Component Name Detection windows Sensor cable Wiper blade Caution Do not carry the sensor with the sensor cable Do not touch the detection window Clean the detection window if your hand touches it...

Page 8: ...uspend the sensor so as not to impinge upon a wall or facility equipment due to water flow In the case of higher water flow fix the sensor With fluctuation of water level taken into account dispose th...

Page 9: ...cts environmental sensor Read the precautions in the TA 1 instruction manual carefully Attach the cable protective cover without fail Otherwise there is a possibility that a cable is scratched during...

Page 10: ...or inserting the lifting lug Run the lifting lug through the end of the chain Open up the ends of the lifting lug and insert into holes of the hanging attachment Reference The chain kit TA 2 for TS 10...

Page 11: ...ing the sensor If the sensor inclines at the time of hanging make horizontal adjustments by changing a point where the cable is fastened on the chain wire Extension of sensor cable The standard length...

Page 12: ...tional area of 0 2 to 1 25 mm2 Refer to Extension of sensor cable P 11 for extension of the sensor cable To extend the sensor cable connection using pull box is recommended Wire the terminal block acc...

Page 13: ...play item For operation refer to the Universal Transmitter SC U1 Operation Manual 5 1 Sensor Setting and Display Item Caution Pressing automatically retains the measurement value Caution When the disp...

Page 14: ...0 seconds or longer If the response is too fast with the factory default setting 5 seconds change the signal output response time as needed Setting range Factory default setting Response Time 5 to 600...

Page 15: ...ignal Output item selection Output item Display Suspended solids SS Transparency Trans For operation refer to the Universal Transmitter SC U1 Operation Manual 5 3 4 20 mA Setting and Output Item Selec...

Page 16: ...t range Lower limit to Upper limit Minimum setting range Upper limit Lower limit Suspended solids SS Lower limit 0 0 Upper limit 1000 0 0 to 1000 20 0 Transparency Trans Lower limit 0 Upper limit 100...

Page 17: ...ids SS Transparency Trans Trigger High Alarm Low Alarm Active Level 0 0 to 1000 0 to 100 Hysteresis High Alarm 0 0 to Active level 0 to Active level Low Alarm 0 0 to 1000 Active level 0 to 100 Active...

Page 18: ...consumables and overhaul timing Check notifications by the relay output and dedicated cloud server SC U1 and GW connected For more information about checking notifications on the cloud server refer t...

Page 19: ...sensor s main unit and detection window 3 Allow the sensor to acclimate to the water temperature for about 5 minutes and check that there are no bubbles in the detection window 2 Immerse the sensor in...

Page 20: ...displayed and then the calibration result is displayed Select ZERO Cal using and press 5 6 DOLEUDWLRQ 66 76 52 DOLEUDWLRQ 5XQQLQJ DOLEUDWLRQ 6HQVRU 6HOHFW S 6 S 66 76 2 26 Measurement item Sensor mode...

Page 21: ...check the result Pressing or switches to the measurement value display good The calibration is properly completed E4100 to 4199 Calibration failed Try the steps again from 1 7 DOLEUDWLRQ 66 76 52 DOLE...

Page 22: ...ustment menu is displayed Display value after offset adjustment Measurement value Set the offset coefficient to add to a measurement value Display the measurement value with offset adjusted to any dis...

Page 23: ...it by and value by and press When a value outside the set range is entered a short beep sounds Pressing simultaneously while entering a value resets the value to the factory default setting By pressin...

Page 24: ...span adjustment value Select a digit by and value by and press 4 GMXVW 66 76 6SDQ GMXVWPHQW Use to switch pages The adjustment menu is displayed When a value outside the set range is entered a short b...

Page 25: ...oint 1 Adjusted value Measurement value Current display value Adjusted value Display value after 2 point adjustment Current display value Point 2 Measurement item Display Measurement item setting rang...

Page 26: ...completed the display returns to the measurement value display Select SS TS 1000 D using and press 2 GMXVW 0HDVXUHPHQW WHP 6HOHFW S 6 S 66 76 2 26 7HPS 26 Measurement item Sensor model Sensor channel...

Page 27: ...r model Sensor channel Reference When a 2 point adjustment is performed the offset and span adjusted values will automatically replace the values calculated from the displayed and adjusted values of t...

Page 28: ...to hold the measurement value Select an item from the following Output item Setting range Factory default setting HOLD Timer OFF 10 to 1440 minutes by 10 minutes 60 minutes For operation refer to the...

Page 29: ...relay output Maintenance output setting P 18 and the dedicated cloud server SC U1 and GW connected For more information about checking notifications on the cloud server refer to the cloud server s he...

Page 30: ...round trip per cycle Item Setting range Factory default setting Cleaning Interval OFF No cleaning 10 to 1440 minutes by 10 minutes 30 minutes For operation refer to the Universal Transmitter SC U1 Op...

Page 31: ...lay returns to the measurement value after a few seconds The sensor cable is broken Make sure that the cable is not damaged If any damage is found contact the dealer The sensor cable is not properly w...

Page 32: ...of the water to measure is out of the usage range The water temperature must be 0 to 40 C E3300 to E3399 Humidity error 66 5 PJ The internal humidity of the unit exceeds its limit The unit must be ov...

Page 33: ...anging bracket for corrosion Immerse the sensor in measurement water of the known concentration and check that the correct value is displayed on the transmitter Perform the following inspections every...

Page 34: ...wiper cleaning system If the sensor is not used over a prolonged period perform the following operations 1 Detach the sensor cable from the transmitter 2 Drain off the water from the sensor and clean...

Page 35: ...sions 32 163 mm excluding Hanging Attachment Weight Approx 930 g Degree of protection IP68 maximum depth of 2 meters underwater type Sensor cable length 9 m Option Transmitter SC U1 Maintenance Kit TC...

Page 36: ...Japan T el 81 77 579 8680 Fax 81 77 579 8199 https www optex co jp e products environmental sensor Whole document of the DOC can be referenced in the following website www optex net UK contact inform...