background image

-  -

ENGLISH

FRANÇAIS

DEUTSCH

IT

ALIANO

ESP
AÑOL

The detection zones of Redwall-V, which may be cause of false 

alarms can be eliminated by masking.

. To confirm detection zones

  Use optional Area View Finder, AVF-

2. To eliminate unnecessary detection zones

  a. Use supplied area masking seals.

  b. Use equiped area masking plates.

The following shows an example;

Detection zones and related segments of the mirror of SIP-3020.

See step 4- and 6.

INSTALLATION AND MAINTENANCE NOTES

Warning

Failure to follow the instructions provided 

with this indication and improper handling 

may cause death or serious injury.

Caution

Failure to follow the instructions provided 

with this indication and improper handling 

may cause injury and/or property damage.

The check   mark indicates recommendation.

The nix   sign indicates prohibition.

Warning

Caution

Never repair or

modify product

Hold the main unit 

securely when you 

install or service it.

If you remove your 

hands from the main 

unit when cables are 

connected to it, the 

main unit may fall 

and the connector 

cables may break 

or the circuit board 

may be damaged.

Caution

Verify that the 

power is off before 

connecting the 

wiring.

2

PARTS IDENTIFICATION 

No.59-564-4 407-3

UL

 No.59-564-4 407-3

INSTALLATION INSTRUCTIONS

Synthesized Intelligent PIR

REDWALL-V series

Synthesized Intelligent PIR

REDWALL-V series

FEATURES

*  Intelligent PIR Detection System

-  Detection of ambient temperature and illuminance for 

automatic sensitivity management

-  Advanced detection algorithm

-  Three dual pyro-elements with patented Double Conductive 

Shielding for main area 

*   Built-in creep zone detector (Double dual pyro-elements) 

*  Anti-vandalism functions

-  Anti-rotation function with accelerometer

-  Anti-masking function with photo-beam

-  Reinforced polycarbonate housing

-  Max. 4m (3ft.) installation height

*  Independent sensitivity selector for creep/near/far areas

*  Detection logic selector

*  Detection range selector

*  Independent N.C. and N.O. outputs

*  Adjustable alarm interval time

REDWALL-V

: Synthesized Intelligent PIR with creep zone

SIP-3020/5

SIP-4010/5

SIP-404/5

*: Not used for the SIP-400/5 and SIP-404/5.

2-

INSTALLATION HINTS

2.3-4.0 m

(7.6-3 ft.)

F

6

4

2

5

3

F 6 F 4 F 2

F 5 F 3 F 

E 6 E 4 E 2

E 5 E 3 E 

D 6 D 4 D 2

D 5 D 3 D 

C 6 C 4 C 2

C 5 C 3 C 

B 6 B 4 B 2

B 5 B 3 B 

E
D
C

B

Area Masking Seals

3020 (52203)

 2 3 4 5 6 7

B

C
D

E

F

F6

F5

F4

F3

F2

E5

E2 E3 E4

D5

D2

C5

C2 C3 C4

B5

B2

B4

D4

D3

B3

E6

D6

C6

B6

Area View Finder

FAR

NEAR

7

6

5

4

3

2

1

B6

C6

D6

E6

B3

C3

D3

E3

F3

B2

C2

D2

E2

F2

B1

C1

D1

E1

F1

B4

C4

D4

E4

F4

B5

C5

D5

E5

F6

F5

Mount the detector so that the majority of 

traffic flow is across the detection pattern.

REDWALL-V  SIP-3020/5

* SIP-400/5 and SIP-404/5 do not 

have a masking function. 

* Creep 

zones can 

not be 

masked. 

* UL-: SIP-3020/5, -400/5 and -404/5 are recommended not to be connected to an 

alarm initiating circuit but may be connected to a trouble alarm circuit if nuisance trips 

are not tolerable.

* UL/c-UL Listed

Base
Fixing screw 

for the base

Main unit

Masking plate for near 

area (*)

Window

Fixing screw 

for the cover

Cover

Far area mirror

Masking plate for far area

Fixing rubber form

Adjustment screws

(two facing each other)

Angle adjustment guide

Near area mirror

Arrow marking

Fixing screw

Nylon wire 

loop

When servicing, the sensor 

can be hooked onto the base 

using the nylon wire loop.

Creep unit

Fixing rubber 

form (*)

Summary of Contents for SIP-3020/5

Page 1: ... area Built in creep zone detector Double dual pyro elements Anti vandalism functions Anti rotation function with accelerometer Anti masking function with photo beam Reinforced polycarbonate housing Max 4m 13ft installation height Independent sensitivity selector for creep near far areas Detection logic selector Detection range selector Independent N C and N O outputs Adjustable alarm interval tim...

Page 2: ...l TAMPER OUTPUT It is detected when the cover is opened It is detected when the main unit is removed from its base Anti Rotation Damage sustained by the main unit is detected If the main unit is impacted in a horizontal or vertical direction and if the position of the main unit has changed damage sustained by the main unit will be detected UL 2 All relay outputs of Alarm Trouble are resistive load...

Page 3: ... detection area Adjust the angle of the main unit in a vertical direction so that you can cover the desired detection area Cautions If the mounting wall is at an angle the arrow of the main unit may exceed the top or bottom limit of Angle adjustment guide Always check this using the area viewfinder or the walk tester If the detection area is too high or too low an object outside the detection area...

Page 4: ... and check that the detection area is correct REDWAVE REDWAVE MICROWAVE REDWAVE ALARM OUTPUT CELL BATTERY POWER SUPPLY FROM SENSOR POWER OFF REDWAVE PIR NEAR REDWAVE PIR FAR MEGARED FAR MEGARED NEAR REDWALL REDWIDE WALKTESTER REDWALL REDWIDE MEGARED CONNECTION SELECT SWITCH MODE SELECT SWITCH POWER SELECT SWITCH OPM WT 1 When the power selector switch is turned to POWER SUPPLY FROM SENSOR position...

Page 5: ...te mounted in the main unit Step 7 Near area Use the masking plate mounted in the main unit 8 1 Attach the masking seal an accessory to the area mirror surface 8 2 Creep zone cannot be masked Connect the walk tester optional to the sensor unit and check that the detection area is correct 1When the power selector switch is turned to POWER SUPPLY FROM SENSOR position after plugging the cable into th...

Page 6: ...t an interval 4 different times to suspend the alarm signal output For example if you set this interval to 30 seconds no more alarm signals will be output for 30 seconds after the output of the first alarm signal If no pedestrians are detected for more than 30 seconds the system returns to the standby mode Then when a pedestrian is detected the alarm signal will be output SELECTOR POSITION FUNCTIO...

Page 7: ...0 0 0 0 20 30 50 40 TOP VIEW Installation height 2 3 m 7 6ft SIDE VIEW Installation height 2 3 m 7 6ft TOP VIEW Installation height 4 0 m 13ft TOP VIEW Installation height 2 3 m 7 6ft DETECTION AREA 6 Applicable models SIP 3020 5 SIP 4010 5 SIP 404 5 TOP VIEW Installation height 4 0 m 13ft SIDE VIEW Installation height 4 0 m 13ft Applicable models SIP 3020 5 SIP 4010 5 SIP 404 5 Applicable models ...

Page 8: ...the window does not fall Do not pull the window using excessive force After you have masked the detection areas mount the window and place the excessive nylon wire loop inside the main unit How to remove the window Applicable models SIP 3020 5 SIP 4010 5 SIP 404 5 3 4 1 2 5 6 7 0 m 5 5 0 5 0 5 ft 30 20 0 0 0 20 30 40 50 50 40 7 6 5 4 2 3 7 TOP VIEW Installation height 4 0 m 13ft Applicable models ...

Page 9: ...cable models SIP 3020 5 SIP 4010 5 SIP 404 5 1 2 3 4 m 5 0 5 ft 0 0 0 m 5 0 5 ft 0 0 0 4 3 2 3 2 SIP 40 0 5 SIP 404 5 Far area mirror Rib Rib Rib Near area mirror 2Attach the masking plate to the mirror and secure it to the ribs 3 Insert the fixing rubber form to secure the knob of the masking plate 1 Remove the masking plate from the storage and check the detection area and the mirror you use by ...

Page 10: ...indow and the cover rain drops may be able to enter into the main unit Mount the cover 1 2 TERMINATION PROCEDURE 9 8 2 Masking the Detection Areas using Masking Seals Using the tweezers an accessory carefully attach the area masking seals an accessory to the near area mirror F 6 E 6 F E D C B E E E E E E D D D D D D C C C C C C B B B B B B F F F F F F 6 4 2 5 3 1 6 4 2 5 3 1 6 4 2 5 3 1 6 4 2 5 3 ...

Page 11: ...reet Where People Walk or Cars Drive by the Detection Area Points Reduce the size of the detection area so that it does not include any public streets Check to see that the arrow of the main unit is within the width of Angle adjustment guide on the adjustment screw Using the area viewfinder check to see that the detection area does not include any public streets If the detection area does go beyon...

Page 12: ...ional heating unit 425mA max 24V AC UL 6 Operation indicator Far alarm and Near alarm Red LED Creep zone alarm Red LED Alarm period Approx 2 sec Warm up period Approx 60 sec Detection range selector Far area ON OFF Alarm interval period 0 15 30 60 sec Detection logic selector AND OR Tamper output UL 7 N C 28V DC 0 1A max Trouble output UL 7 N C 28V DC 0 2A max Alarm output UL 7 Main area N C 28V D...

Reviews: