background image

LONG RANGE

 

(OPTIONAL LENS : FL-60N)

1. INSTALLATION  HINTS

Avoid looking directly at air
conditioning or heating vents.

Do not install outdoors.

2. DESCRIPTION AND OPERATION

3. DETECTION AREA

When selecting the long range
detection pattern , always set
pulse count selector to "2".

FL-60N

Engraved

LONG RANGE

COVER INSIDE

Avoid direct sunlight.

Avoid vapor or high humidity
that can cause condensation.

Avoid Curtain,Screen,etc.
blocking detection area.

To remove , press both lens hooks
to outside and push to the front.
To fit , press the lens into cover
from  the front .

WIDE ANGLE

IMPORTANT

 

 

 

 HOW TO REMOVE & FIT LENS

     

PATTERN AREA SELECTION

 

   TOP VIEW

0

2

4

6

8

10

12m

40 ft

35

30

25

20

15

10

5

2.4m

8 ft

0

5

15

10

12m

10

6

8

4

2

4

2

0

2

4

6

20 ft

10

15

5

0

6

40 ft

35

30

25

20

15

10

5

20 ft

    

SIDE VIEW

LED ON/OFF Switch

Wiring Knockouts

Tamper Switch

Sensor
(Do not touch)

Mounting Knockout
(Pitch = 2.63inch/66.7mm)

Pulse Count Selector
( 2 / 4 )

Terminals

Sealed Optics Foam

LENS

Cover Fastening Screw

Wiring Guide

LED Alarm

Indicator

Use the optional lens FL-60N
for long range area.

FEATURES

- 40ft. - 40ft.(12m - 12m)Wide Angle

- QUAD Zone Logic

- Patented Multi-focus Lens

- Improved Sealed Optics

-Temperature Compensation Logic

FUNCTION

- Selectable Pulse Count(2 or 4)

- LED ON/OFF

- Tamper Switch

OPTION

-

 FL-60N  Long Range Curtain Lens(60ft/18m)

- FA-3 Wall & Ceiling Mount Bracket

 (Horizontally ± 45° & Vertically 0° - +5°)

(1)

(2)

(3)

(4)

(5)

PASSIVE INFRARED DETECTOR

RX-40QZ

EASY INSTALLATION

- Easy Wiring Knockout

- Wiring Guide

- Spare Terminal

- Wide Wiring Space

No.59-0757-3 0105-17