background image

EN-1

CONTENTS

1 INTRODUCTION

  1-1 PREPARATION........................................................................................... 1

  1-2 PRECAUTIONS .......................................................................................... 1

  1-3 PARTS IDENTIFICATION........................................................................... 2

  1-4 DETECTION AREA..................................................................................... 2

  1-5 INSTALLATION WORK FLOWCHART....................................................... 2

2 MOUNTING TYPE AND ASSEMBLY OPTIONS

  2-1 MOUNTING TYPE ...................................................................................... 3

  2-2 DISASSEMBLY ........................................................................................... 4

  2-3 ASSEMBLY OPTIONS................................................................................ 4

3 BEFORE INSTALLATION

  3-1 REMOVING THE FRONT COVER ............................................................. 6

  3-2 MOUNTING THE FRONT COVER ............................................................. 6

  3-3 REMOVING THE LASER WINDOW ........................................................... 6

  3-4 MOUNTING THE LASER WINDOW ........................................................... 6

  3-5 WIRING CABLE ENTRY ............................................................................. 6

  3-6 INSTALLING NETWORK CABLE ............................................................... 7

4 INSTALLATION AND ANGLE ADJUSTMENT

  4-1 WALL OR CEILING MOUNTED.................................................................. 7

  4-2 ANGLE ADJUSTMENT ............................................................................... 7

  4-3 LASER AREA CONFIRMATION ................................................................. 7

5 PARTS LAYOUT INSIDE AND THEIR FUNCTIONS

  5-1 WIRING ....................................................................................................... 8

  5-2 PROGRAMMABLE SIGNAL OUTPUT........................................................ 8

  5-3 PROGRAMMABLE SIGNAL INPUT (RLS-2020S only) .............................. 8

  5-4 ETHERNET PORT (PoE)............................................................................ 8

  5-5 MAINTENANCE SECTION ......................................................................... 8

  5-6 MAINTENANCE PORT ............................................................................... 8

  5-7 POWERING ON .......................................................................................... 8

  5-8 INITIALIZATION TO FACTORY DEFAULT ................................................ 8

  5-9 LED INDICATOR......................................................................................... 8

6 SETTING

  6-1 OVERVIEW ................................................................................................. 9

  6-2 DETECTION CONFIGURATION ................................................................ 9

  6-4 NETWORK OPTIONS............................................................................... 10

  6-5 AUTHENTICATION..................................................................................

.

10

  6-6 MAINTENANCE ........................................................................................ 11

  6-7 REDWALL EVENT CODE......................................................................... 11

7 DIMENSIONS

  7-1 DIMENSIONS............................................................................................ 11

8 SPECIFICATIONS

  8-1 SPECIFICATIONS .................................................................................... 11

  8-2 OPTIONS .................................................................................................. 12

9 APPENDIX

  9-1 REPAINTING ............................................................................................ 12

FEATURES

1

INTRODUCTION

1-1

PREPARATION

• Read this instructions carefully prior to installation.

 

This instructions uses the following warning indications to provide information 

regarding correct usage of the product to prevent harm and damages to assets. 

These warning indications are described below

Ensure these precautions before reading the rest of this instructions.

Install the product so that the detection

area is not influenced by interference 

from tall grass or tree branches waving 

in the wind.

Do not install or leave the product in a 

location exposed to heat, vibrations or 

impacts.

Do not use the product in an 

environment where solvent fumes or 

corrosive gases are present.

NO. 59-2408-6

INSTALLATION INSTRUCTIONS

Indoor/Outdoor model

Indoor only

RLS-2020S

Laser Scan Detector

Laser Scan Detector

RLS-2020S

RLS-2020

RLS-2020

This symbol indicates prohibition.

The specific prohibited action is provided in and/or around the figure.

This symbol requires an action or gives an instruction.

This product is not a safety component as per the machinery directive.

Do not use it for the purpose of machine safet

y.

Do not touch the unit base or power terminals of the product with a wet 

hand (do not touch when the product is wet with rain, etc.). It may cause 

electric shock.
Never attempt to disassemble or repair the product. It may cause fire or

damage to the devices.
Do not exceed the voltage or current rating specified for any of the 

terminals, doing so may cause fire or damage to the devices.
Ensure the power is turned off before wiring.

Confirm the type of each terminal to ensure wiring is carried out correctl

y.

Whenever a commercial switching regulator is used, be sure to connect 

PE (Protective Earth

 T

erminal).

Clean and check the product periodically for safe use.

If any problem is found, do not attempt to use the product as it is.
When disposing of this product, be sure to follow the waste-disposal 

regulations of the country or region where it is used.

Hold the main unit securely when you install or service it. Exercise care 

not to bump the product against nearby objects or drop it inadvertentl

y.

This product is not capable of detecting objects in the dead zone of the 

laser scan.

Do not use this product for an application where it is not capable of 

covering the detection area required by the task.
Please note that the product can malfunction, including producing an

irregular output and committing a detection error, if it is exposed to 

unfavorable environmental conditions such as strong ambient light, 

electronic noises or mechanical vibrations.

Use of controls or adjustments or performance of procedures other than 

those specified herein may result in hazardous radiation exposure.

This product is intended to detect an intruder(s) and is not designed to 

prevent theft, disasters or accidents.

 

The manufacturer shall not be held 

liable for any damage to user

s property resulting from theft, disasters or 

accidents.

Do not use this product in environments where there may be oil mist particles 

which may contaminate the window of the detector; thus causing detection errors 

and possible corrosion which may lead to product failure.

There should not be any obstructs (e.g. lighting equipment, fire detectors, 

cameras, poster, etc.) in the laser area.

After installation, any obstructs should not be carried/moved into the detection area.

• 20 x 20 m (65 x 65 ft.), 95 degrees detection area

• Vertical and Horizontal detection area

• Multi-angle Adjustment Shell Structure (M.A.S.S.)

• Automatic area setting function

• Advanced area setting

• 4 adjustable detection areas on IP connection

• Total 3 outputs can be assigned for analog connection

• Anti-masking, Anti-rotation, Soiling, Device trouble, Tamper output (selectable)

• Paintable housing

• Supporting multiple network protocols

 

RLS-2020S

• Indoor and Outdoor use

• Indoor high resolution mode

• Indoor throw-in mode

• Area selection

• Environmental disqualification circuit (DQ)

1-2

PRECAUTIONS

mini

The check        mark indicates recommendation.

Caution

Warning

EN

(UL) 59-2408-4 1703-01

Failure to follow the instructions provided with this indication and 

improper handling may cause death or serious injur

y.

Failure to follow the instructions provided with this indication and 

improper handling may cause injury and/or property damage.

Install the product only on a solid 

surface.

Do not install the product on an 

uneven surface.

A

void mounting near vents or devices 

which cause high levels of smoke or 

condensation.

W

arning

Caution

SECURITY

UL

LISTED

R

  6-3 NETWORK CONFIGURATION................................................................. 10

Summary of Contents for Redscan Mini

Page 1: ...iring is carried out correctly Whenever a commercial switching regulator is used be sure to connect PE Protective Earth Terminal Clean and check the product periodically for safe use If any problem is found do not attempt to use the product as it is When disposing of this product be sure to follow the waste disposal regulations of the country or region where it is used Hold the main unit securely ...

Page 2: ...uant to Laser Notice No 50 dated June 24 2007 Class 1 laser product Do not expose your eyes directly to the laser beam On Safety of Laser Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures EN 55032 CE Statement Walk test and confirm the detection area Refer to 4 3 Change the assembly...

Page 3: ... Type C Type D Type B Type A Horizontal Detection Area CEILING MOUNT WALL MOUNT Type C Type A 2 MOUNTING TYPE AND ASSEMBLY OPTIONS 2 1 MOUNTING TYPE RLS 2020 has type A B C and D to be installed Select the correct type of assembly to match the installation For the vertical detection area to the mounting surface be sure that the fixing screw of the front cover is placed on top The detector can crea...

Page 4: ...pply loads to the wiring Note 1 2 3 Disassembling is not required to use type A factory default 2 Turn over the unit and adjust the position of the screw hole and tighten the screw at the center 3 Mount the side cover L side cover S and side cover cap 2 1 3 Note Mount the cover caps and the logo must be displayed horizontally Note 1 2 Side cover L Note Before assembling confirm the arrow mark on t...

Page 5: ...e of the main unit and the one at the center of the base cover as indicated Note Note Note Note Then place the main unit on the base unit so as to match the screw hole of the main unit and the one at the center of the base cover as indicated Side cover L Fixing screw The positions of the fixing screw and side cover are shown below Side cover L Fixing screw The positions of the fixing screw and sid...

Page 6: ...g or removing the laser window 3 3 REMOVING THE LASER WINDOW As shown in the figure below use the supplied allen key to put out the hook upward in a leverage motion 3 4 MOUNTING THE LASER WINDOW As shown in the figure below insert the foot of the laser window until it clicks 3 5 WIRING CABLE ENTRY Use a screwdriver to open a knockout 2 wiring holes Make a slit with a cutter Wiring hole on the back...

Page 7: ...N AND ANGLE ADJUSTMENT 4 1 WALL OR CEILING MOUNTED Caution Do not supply the power for this unit during wiring 1 Remove the mounting bracket from the base using a tool such as flathead screwdriver Methods for ceiling mounting and wall mounting are the same 2 Place the supplied paper template on the mounting surface and open 2 mounting holes 3 Mount the mounting bracket to the mounting surface Scre...

Page 8: ...ms initial settings Reset button 1 Turn Off the power supply Remove the front cover and laser window refer to 3 1 3 3 2 Power On while pressing the reset button 3 All LEDs turn On Red LED turns Off after 50 sec and green LED turns Off after 2 sec And then release the reset button Yellow LED turns off after 3 sec 4 Turn Off the power supply Attach the laser window and the front cover Then Power On ...

Page 9: ...longer distance In regular indoor mode the resolution is 0 25 degree In this high resolution mode it gets 0 125 degree Thus the same small size object can be detected at the double distance But fastest response time can be within 100 ms in this mode the unit may not detect fast movement object This mode shall be use for only indoor application Indoor throw in mode RLS 2020S only This mode can work...

Page 10: ...se time Indoor mode Default M 150 ms H 75ms L 500 ms Custom Can be set from 75 to 900 000 ms 15 min Outdoor mode Default M 150 ms H 75 ms L 500 ms Custom Can be set from 75 to 900 000 ms 15 min Indoor high resolution mode Default M 200 ms H 100 ms L 500 ms Custom Can be set 100 to 900 000 ms 15 min Indoor throw in mode Fixed to 0 ms every scan report alarm Indoor Outdoor Indor throw in mode Target...

Page 11: ...es original ASCII event codes which can be used by an NVR or VMS software to control PTZ cameras and other devices Communication methods REDWALL EVENT CODE can be sent to the assigned port using UDP or TCP protocol The default port number is 1234 Code format 6 7 REDWALL EVENT CODE R E C ID number of the RLS 2020 unit consist 6 bytes as follows RLS 3 bytes number Default number is the last group of...

Page 12: ...sibility that the unit would be exposed to direct sunlight 9 APPENDIX 9 1 REPAINTING 1 2 3 4 Note Be careful not to lose the removed washer 1 2 3 8 2 OPTIONS LAC 1 Laser area checker RLS PB Pole mounting bracket RLS RB Recessed mount kit RLS LW REDSCAN mini laser window In case of using DC power supply UL required the main unit to be connected to a UL listed PoE injector or switch and the PoE must...

Reviews: