13
Input
Copyright (C) 2016 OPTEX CO., LTD.
CONFIDENTIAL
Physical
circuit
status
Input
trigger type
Wat happens
when
triggered
Note
Wake L
Open
Normally
Open
Enhances the
sensitivity of
detection
The default setting
Wake H
Open
Normally
Closed
Enhances the
sensitivity of
detection
If no closed connection is made,
the device will stay at “Enhanced”
sensitivity.
(No human cancellation)
Inhibit L
Open
Normally
Open
Mute the
sensitivity of
detection
The device will not detect when
the input circuit is closed.
Inhibit
H
Open
Normally
Closed
Mute the
sensitivity of
detection
If no closed connection is made,
the device will stay at muted.
(No trigger at all)
Human detection (HD) mode
If no closed connection is made on
the input terminal, the device will
stay at “Enhanced” sensitivity.
Then, the device will go off by a
human presence.