-5-

2-3 TRANSMITTER PREPARATION

2-4 BEFORE MOUNTING

<When monitoring ALARM and TROUBLE using the transmitter with 1 external input>

<To monitor only the ALARM using a transmitter 

with 1 external input>

<To monitor the ALARM and TROUBLE using a 

transmitter with 2 external inputs>

35 (1.38)

130 (5.12)

30 (1.18)

External input is N.C.

External input is N.O.

3

... DIP switch 3: OFF (N.C.)

3

... DIP switch 3: ON (N.O.)

Connectors to be used

Connector for POWER and ALARM

Connector for TROUBLE

Red

Black

How to position a battery

Connector for POWER
and ALARM

Connector for
TROUBLE

Connector for
POWER and ALARM

N.C.

N.O.

Unit: mm (inch)

The transmitter used should have the internal dimensions of H 150 × W 34 × D 33 mm(H 5.91 × W 1.34 × D 1.30 inch)
or H 112 × W 55 × D 35 mm.(H 4.41 × W 2.17 × D 1.38 inch)

WRS-04 (option)

Store the connecting 
cable in a  trench 
and seal with a label 
already in place.

Remove the cap.

1

Open the cover unit.

2

Remove the main unit from 
the back box.

3

Remove the back box 
from the mounting plate.

4

Mount the wall tamper 
(WRS-04) on the back  
of the main unit.

1

Run the wire along 
the wiring groove.

2

2-5 WALL TAMPER WRS-04 (OPTION)

Summary of Contents for Infinity VXI-R

Page 1: ...AREA 2 3 4 4 4 5 5 5 6 7 7 8 9 11 12 13 13 14 14 15 BATTERY OPERATED MODEL MULTI DIMENSIONAL OUTDOOR DETECTOR MULTI DIMENSIONAL OUTDOOR DETECTOR The VX InfinityTM series provide highly reliable detect...

Page 2: ...or property damage The check mark indicates recommendation The nix sign indicates prohibition Sunlight and reflection Heat source Objects moving in the wind 0 8 1 2 m 2 64 3 94 ft Parallel Do not rem...

Page 3: ...ng plate Connector for TROUBLE 1 0 m 3 28 ft or more Less than 1 0 m 3 28 ft Velcro tape VXI R VXI RAM VXI RDAM Do not install two or more VXI RDAMs in side by side or face to face Doing so may cause...

Page 4: ...er Gray Tamper Green Blue Brown Orange Gray Mount the battery box inside the back box as shown below Insert the battery box along the groove of the back box Click Back box Battery box mounting space 1...

Page 5: ...or TROUBLE Red Black How to position a battery Connector for POWER and ALARM Connector for TROUBLE Connector for POWER and ALARM N C N O Unit mm inch The transmitter used should have the internal dime...

Page 6: ...The battery in the transmitter is shared with the detector Connection for TROUBLE is used when monitoring for Tamper and Anti Mask Use a metal band with 25 mm or less in width Put the top of the back...

Page 7: ...s an unwanted object within the detection area apply an area masking label to the appropriate area Insert the protruding part of the cover into the lens hole Fit the edge of the lens Slide the lens ho...

Page 8: ...IR to the desired position 2 Adjust the MW detection length by rotating the MW sensitivity adjustment according to the PIR area Detection length setting chart The detection lengths described above sho...

Page 9: ...active Caution After completing a walk test always set the unit to NORM position for operation Using the unit in TEST mode will shorten the battery life 120S 5S BATTERY SAVING TIMER VXI R VXI RAM VXI...

Page 10: ...XI RAM VXI RDAM ON 1 2 3 4 5 6 POSITION FUNCTION OFF ON Factory default ANTI MASKING ON ANTI MASKING OFF When masking condition continues more than 3 minutes TROUBLE will be generated TROUBLE is gener...

Page 11: ...ogic is activated Use this under harsh environment e g vegetation sway MICROWAVE IMMUNITY logic is not activated POSITION FUNCTION HIGH MIDDLE Factory default High sensitivity LOW Low sensitivity Midd...

Page 12: ...etection VXI RAM only Blinks 3 times and then repeats Note The LED blinks even if the DIP switch 4 LED is set to OFF Detector condition LED indicator Warm up Blinks for approx 60 seconds Alarm RED LED...

Page 13: ...VDC 1300 mAh CR2 3 VDC 750 mAh 1 2AA 3 6 VDC 1000 mAh Approx 5 years Approx 4 years Approx 4 years Approx 3 years Approx 2 years Approx 1 years Approx 3 years Approx 2 years Note Data shown here is w...

Page 14: ...ate Switch 10 V DC 0 01 A max Alarm output Trouble output LED indicator Disable During normal operation Enable During WALK TEST or LED SW on Red Warm up alarm masking detection VXI RAM only Disable Du...

Page 15: ...ides Five patterns of special detection areas can be configured by applying a masking sticker 1 5 10 m area can be set 10 1 5 m area can be set 5 10 m area can be set 10 5 m area can be set a b c d e...

Page 16: ...ective 2004 108 EC Applied Standards EN 50130 4 1995 A1 1998 A2 2003 EN 55022 2006 VXI RDAM also complies with following Directives Standards marked Class II Directive R TTE Directive 1999 5 EC Applie...

Reviews: