3
MANUFACTURER'S STATEMENT
5921352 MA
Y
2016
Model
Cover color
Mounting height
Detection area
Detection method
Depth angle
adjustment
Power supply
Power consumption
Operation indicator
Activation output
: i-oneX T
: Black
: 6'7" to 9'10" (2.0m to 3.0m)
: See
DETECTION AREA
: Active infrared reflection
: Approach area -15° to +10°
Presence/Motion area -10° to +8°
: 12 to 24VAC ±10% (50 / 60 Hz)
12 to 30VDC ±10%
: < 2.5W (< 4VA at AC)
: See
Operation indicator table
Output hold time
Response time
Operating humidity
IP rate
Weight
Accessories
: 0.5 to 1.5sec.
: < 0.3sec.
Operating temperature : -31°F to 131°F(-35°C to +55°C)
: < 80%
: IP54
: 14.6oz (420g)
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
The specifications herein are subject to change without prior notice due to improvements.
NOTE
MANUFACTURER'S STATEMENT
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of the equipment.
Danger of electric shock
WARNING
CAUTION
NOTE
Disregard of the warning symbol can cause improper operation which may cause death
or serious injury.
Special attention is required to the section of this symbol.
Disregard of the caution symbol can cause improper operation which may cause injury of a
person or damage the object.
NOTE
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of
a person.The meanings of the symbols are as follows.
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door.
Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which
the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building
owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
Operation indicator table
CAUTION
Risk of getting caught
Make sure to affix the mounting template as described in the above chart,
otherwise it can be dangerous since there may be no detection area around
the threshold. Install the sensor as low as possible on the header.
WARNING
Danger of electric shock
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain cover
(Separately available) otherwise electric shock or breakdown of
the sensor may occur.
Before starting the procedure, make sure that the power is turned OFF.
When passing the cable through the hole, do not tear the shield
otherwise it may cause electric shock or breakdown of the sensor.
Wire the cable to the door controller as shown below.
1.Plug the connector.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See
ADJUSTMENTS 5. Dipswitch settings, Table 1)
Place the housing cover.
If wiring is to be exposed, break the knockout.
H : Height from the floor to the bottom of the header
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
WARNING
Danger of electric shock
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 seconds in order to enable the presence detection.
Do not touch the dipswitches before turning the power ON, otherwise an error occurs.
INSTALLATION
The following conditions are not suitable for sensor installation.
-Fog or exhaust emission around the door
-Wet floor
-Vibrating header or mounting surface
-Moving objects, steel plate, emergency lights or illumination in the detection area or in vicinity
-Highly reflecting floor or highly reflecting objects around the door
NOTE
X
H
Y
Sensor
Door
Header
Floor
SPECIFICATIONS
1. Affix the mounting template at the desired mounting position.
Refer to the chart in below.
2. Drill two mounting holes of ø1/8" (ø3.4mm).
3. To pass the cable through the header, drill a wiring hole of ø5/16" (ø8mm).
4. Remove the mounting template.
5. Remove the housing cover with screw driver as shown below.
Fix the sensor to the mounting surface with the two mounting screws.
i-oneX T
1
2
4
1sec.
1sec.
Stand-by (installation mode)
Stand-by (operation mode)
Sensor failure
Signal saturation
2nd row detection
BLUEZONE (1st row) detection(
*1)
3rd/4th row detection
5th row detection
Status
Green
Fast Green blinking
Slow Green blinking
Yellow
Orange
Red
Operation indicator color
Red blinking
Blue
Maximum distance (Y)
X
6'7" (2.00)
7'7" (2.30)
8'2" (2.50)
9'2" (2.80)
0
No limit
2" (0.05)
5" (0.12)
4" (0.10)
3" (0.08)
6" (0.15)
2" (0.06)
8" (0.20)
10" (0.25)
12" (0.30)
-
-
H
4" (0.10)
-
-
[feet,inch(m)]
9'10" (3.00)
4" (0.11)
-
NOTE
Make sure not to mount the bottom of the sensor lower than the bottom of the header.
Knockout
Knockout
*1 : See
BLUEZONE AREA
2" (0.05)
Approach (6th row) detection
Orange blinking
OUTER DIMENSIONS AND PART NAMES
(1) Connector
(2) Mounting holes (for retrofit)
(3) Mounting holes
(4) Operation indicator
(5) Width adjustment screws
(6) Depth angle adjustment screw (Presence/Motion)
(7) Depth angle adjustment screw (Approach)
(8) Sensitivity potentiometers
(9) Dipswitches
(10) Detection window
(11) Cover fixing
(12) Area adjustment tool
[inch (mm)]
BLUEZONE AREA
BLUEZONE
(1st row)
2nd row
3rd row
BLUEZONE
(1st row)
2nd row
3rd row
1 7/16" (36)
4 15/16" (125)
4 13/16" (123)
9 13/16" (250)
1' 5/16" (312)
5/16" (8)
2 1
1/16" (67.5)
2 1/16" (52.5)
(1)
(2)
(4)
(5)
(7)
(8)
(9)
(10)
(12)
(2)
(6)
Approach
(6th row)
5th row
4th row
Approach
(6th row)
5th row
4th row
DETECTION AREA
The actual detection area may become smaller depending on the ambient light, the color / material of
the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than
2"(50mm) / sec. or faster than 4'11"(1500mm) / sec.
NOTE
The chart shows the values at depth angle 0°
[feet,inch(m)]
Approach area
*Mounting Height = 7'3"(2.2m)
[feet,inch(m)]
0°
10°
-15°
2" (0.05)
2" (0.06)
3" (0.07)
4" (0.10)
4" (0.10)
3" (0.08)
3" (0.08)
3" (0.08)
3" (0.07)
3" (0.08)
3" (0.08)
4" (0.09)
4" (0.09)
4" (0.09)
4" (0.10)
4" (0.11)
4" (0.11)
4" (0.09)
5" (0.12)
1
Insert
Screw driver
Cover fixing
Screw driver
2
Slide
Lock release is in the identical position
on both side of the sensor.
(3)
(3)
(11)
(11)
Presence area
Motion area
Approach area
Test input
: Opto coupler
Voltage 5 to 30VDC
Current 6mA Max.(30VDC)
: Form A relay
50V 0.3A Max.(Resistance load)
Safety output
: Form A relay
50V 0.3A Max.(Resistance load)
2nd row overlapping
the threshold
-15°
0°
+10°
L
M
O
Q
S
4'9" (1.45)
6'9" (2.06)
8'1" (2.46)
(3.65)
7'1" (2.15)
8'2" (2.50)
10'6" (3.20)
11'8" (3.56)
(4.27)
15'7" (4.76)
2'2" (0.67)
5'1" (1.54)
5'7" (1.69)
8'3" (2.52)
(3.66)
A
B
C
D
E
F
G
H
7'3" (2.20)
6" (0.16)
7" (0.17)
1'8" (0.50)
2'10" (0.86)
3'7" (1.09)
9'10" (3.00)
8" (0.21)
9" (0.24)
2'4" (0.70)
3'11"(1.19)
4'11" (1.49)
8'2" (2.50)
7" (0.18)
8" (0.20)
1'11" (0.58)
3'3" (0.99)
4'1" (1.24)
9" (0.22)
(0.31)
10" (0.25)
4'9" (1.45)
6'6" (1.98)
5'5" (1.65)
I
8'1" (2.46)
(3.35)
9'2" (2.79)
J
4'6" (1.38)
6'2" (1.89)
5'2" (1.57)
K
7'1" (2.15)
9'8" (2.95)
(2.45)
L
8'4" (2.53)
11'4" (3.45)
9'5" (2.88)
M
10'6" (3.20)
14'4" (4.38)
(3.65)
N
16'6" (5.02)
13'9" (4.18)
O
13'5" (4.10)
18'4" (5.60)
15'4" (4.67)
P
16'9" (5.10)
22'10" (6.95)
(5.79)
12 to 24VAC±10% / 12 to 30VDC±10%
Opto coupler / Voltage: 5 to 30VDC
1.Grey
2.Grey
3.White
4.Yellow
5.White stripe
6.Yellow stripe
7.Red (+)
8.Black (-)
Power
supply
Safety
output
Activation
output
2
1
3
4
Test
input
1
2
3
4
Form A relay 50V 0.3A Max.
Form A relay 50V 0.3A Max.
Mounting
surface
B
A
J
F
O
Q
R
T
H
E
D
C
N
P
S
2nd row
BLUEZONE
3rd row
4th row
5th row
Approach
(1st row)
G
I
K L
M
Q
R
T
U
U
2" (0.06)
3" (0.07)
3" (0.08)
1'7" (0.49)
1'10" (0.55)
2'2" (0.65)
2'8" (0.82)
3'1" (0.93)
3'8" (1.11)
3'5" (1.04)
3'10" (1.18)
4'8" (1.41)
(The mounting height is "H + Y".)
When dipswitch 5 is set to "ON", the BLUEZONE area, that provides extra safety over the threshold, is activated.
In case the BLUEZONE function is not required, set dipswitch 5 to "OFF".
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 5.
(6th row)
1 Cable 9'10" (3m)
8'
1'
12'
14'
:1st-4th row
:5th row
:6th row
12'
19'
12'
11'
(4.27)
19'2" (5.84)
15'11" (4.86)
S
14'
12'1" (3.68)