background image

  

 
 
 

Jumper On: After transmitting for a detected movement, any further movement detection will transmit the event code again (and the captured images) 
(

default

). 

Jumper Off: PIR Camera has a “

sleep time

” of approximately 1 minute to conserve power.  

 

FEATURES 

IMAGE CAPTURE 

When the alarm system is armed, the PIR Camera will capture 3 or 6 alarm images in 640 x 480 or 320 x 240 resolutions (programmable from control 
panel) upon movement detection. You can also manually request the PIR Camera to take a picture through CIE. The captured images will be transferred 
to ZigBee coordinator or CIE for user to view. 
 

WARM UP PERIOD 

When the ZigBee system enters arm mode, or when PIR Camera is put into Test Mode, the PIR Camera will warm up for 30 seconds. Do not trigger the 
PIR Camera during the 30-second warm up period. If the PIR Camera is under low battery or tamper opened condition, the Blue LED will light up during 
the warm up period. 
 

SLEEP TIMER 

When 

Jumper Switch 2

 is set to Off, the PIR Camera has a “

sleep time

” of approximately 1 minute to conserve power. After transmitting for a detected 

movement, the PIR Camera will not retransmit for 1 minute. Any detected movement during this period will reset the sleep time to 1 minute. Continuous 
movement in front of the PIR Camera will therefore not exhaust the battery. 

 

BATTERY AND LOW BATTERY DETECTION 

The PIR Camera uses two

 1.5V “AA” Lithium batteries 

in series connection as its power source. Remove the Battery Compartment Cover and insert 

the batteries to activate the PIR Camera. 
The  PIR  Camera  features  Low  Battery  Detection  function.  When  the  battery  voltage  is  low,  the  PIR  Camera  will  transmit  Low  Battery  signal  to  the 
coordinator in ZigBee network. If movement is detected under Low Battery condition, the Blue LED will light up for 2 seconds. 
When  changing battery,  after removing the  old  battery,  press the Tamper Switch  or  the Function  Button  twice to fully  discharge  before inserting new 
batteries 
 

TAMPER PROTECTION 

The PIR Camera is protected by a tamper switch which is compressed when the PIR Camera is properly installed. When the PIR Camera is removed 
from mounted surface or its cover opened, the tamper switch will be activated and the PIR Camera will send a tamper open signal to the ZigBee network 
coordinator or system control panel to remind the user of the condition. If movement is detected when the tamper switch is open, the Blue LED will light 
up for 2 seconds. 

  PIR Camera will not detect the status of the tamper switch within 5 minutes of inserting battery. 

  If the  Tamper  Switch  is  triggered during  this  5-minute  non-detection period, the  PIR  Camera  will transmit a tamper status signal to the  ZigBee 

network coordinator or system control panel immediately after the 5-minute non-detection period. 

 

When the tamper switch is compressed, Factory Resetting the PIR Camera is disabled. 

 

SUPERVISION 

The PIR Camera will transmit a supervision signal to report its condition regularly according to user setting. The factory default interval is 30 minutes. The 
user can also press the Function Button once to transmit a supervision signal manually. 

 

TEST MODE 

  Test mode is for you to check the PIR camera’s detection range (not shooting coverage). 

  To enter Test mode, press and hold the Function button over 3 seconds and release the button to enter the Test mode for 3 minutes. 

  The PIR camera will warm up for 30 seconds. Please do not trigger the Camera during this warming-up period.  

  After the  warm-up period,  you  can trigger  PIR camera  to  check IR detection range. If  PIR camera  is triggered,  the  Blue LED  will  light  up for  2 

seconds. 

 

ZigBee NETWORK SETUP 

ZigBee DEVICE GUIDELINE 

ZigBee  is  a  wireless  communication  protocol  that  is  reliable,  has  low  power  consumption  and  has  high  transmission  efficiency.  Based  on  the 
IEEE802.15.4  standard,  ZigBee  allows  a  large  amount  of  devices  to  be  included  in  a  network  and  coordinated  for  data  exchange  and  signal 
transmission. 
Due to the fundamental structure of ZigBee network, ZigBee device will actively seek and join network after powering on. Since performing a task in 
connecting network may consume some power, it is required to follow the instructions to avoid draining battery of a ZigBee device 

  Ensure your ZigBee network router or coordinator is powered on before inserting battery into the ZigBee device. 

  Ensure the ZigBee network router or coordinator is powered on and within range while a ZigBee device is in use. 

  Do not remove a ZigBee device from the ZigBee network router or coordinator without removing the battery from a ZigBee device. 

 

JOINING THE ZigBee NETWORK 

As a ZigBee device, the PIR Camera needs to join a ZigBee network to transmit signal when a movement is detected. Please follow the steps below 
to join the device into the ZigBee network. 
 

THE PIR CAMERA CAN ONLY JOIN ZigBee NETWORK WITHIN 3 MINUTES AFTER POWER ON.

 

Step1. 

Remove the Battery Compartment Cover by loosening the Battery Compartment Screw. 

Step2. 

Insert the batteries. Orient the battery according to the polarity indication. 

Step3. 

Make sure the tamper switch is open.

 

Step4. 

Within 3 minutes after power on,

 Press and hold the function button for 10 seconds, release the button when both the Blue LED and 

flash LED flash once. Please make sure to enable the permit-join feature on the router or coordinator of your ZigBee network.  

Step5. 

After joining the ZigBee network, the PIR Camera will be registered in the security system in the network automatically. Please check the 
ZigBee network coordinator, system control panel, or CIE (Control and Indicating Equipment) to confirm if joining and registration is 
successful. 

Step6. 

After joining the ZigBee network, if the PIR Camera loses connection with the ZigBee network, the LED will flash 20 minutes to indicate. 
Please check your ZigBee network condition and PIR Camera signal range to correct the situation. 

 

Jumper On 

The jumper link is inserted 
connecting the two pins. 

Jumper Off 

if the jumper link is removed 
or “

parked

” on one pin.

 

Reviews: