background image

- 3 -

- 2 -

DESCRIPTION AND OPERATION

3

INSTALLATION

4

ADJUSTMENTS FOR REQUIRED AREA PATTERN

6

FUNCTIONS

7

Lead in wires through knockouts

along the wiring guide on the

rear side of base. Mount base

with supplied screws. When

using a bracket, check matching

knockout position before opening

mounting holes. Wire according

to Section 5.

1

2

1

3

The CX-702 MKII is designed to provide ideal detection areas for different patterns ranging from 12 m (40 ft.) to 21 m (70 ft.) Wide Angle, and 

24 m (80 ft.) to 45 m (150 ft.) Long Range. The following adjustments will provide ideal detection areas for each of these requirements.

LED ON / OFF

2

PULSE COUNT

The Detection Mode can be switched to either “2” or “4” mode

d

epending on the environmental conditions of the installation.

2 : For normal applications.

4 : For use in hostile areas where there may be movement of small 

     animals or other objects such as fax machines or curtains.

When the “4” is selected, the detector’s sensitivity may seem sluggish. It is 

therefore important to always conduct a walktest to ensure that the desired 

coverage is given.

J

umper Pin Switch

The Alarm LED indicator can be switched either “ON” or “OFF”.

1

3

DETERMINE THE AREA PATTERN

2

SELECTING WIDE ANGLE OR LONG RANGE DETECTION

VERTICAL ADJUSTMENT OF DETECTION AREA

1. Inverting the lens will select either the Wide Angle or Long Range detection patterns.

2. Please note markings “W (Wide Angle) ” and “L (Long Range) ”, on each side of lens.

3. For Wide Angle, “W” will be on top of lens.

4. For Long Range, “L” will be on top of lens.

1. Set the upper edge of the lens at either the “A”, “B” or “C” position.

2. The following chart illustrates the different position setting.

3. Confirm the detection area by conducting a walktest.

Before 

making adjustments, determine the pattern area, detection range mounting height.

Adjust the vertic

al angle according to the desired detection range and mounting height.

Cover

Lens

LED Indicator

Terminals

Tamper switch

Sensor

Do not touch.

Cover Fastening

Screw

Base

Wiring Knockout

Lens Holder

Corner mount Knockout

Double Conductive Shield

Do not touch.

Mounting Knockout

Pitch 83.5 mm (3.29 inches)

Fit cover using fastening screw.

4

Guides of Cover

Guides of Lens Holder

2

ON

OFF

4

Do not use pulse count 4 

for Long Range detection.

Always conduct a walktest after

changing the position of this

switch to ensure the detector is

still providing optimum coverage.

CAUTION

W : WIDE ANGLE

DISTANCE

HEIGHT

1.5 (5)
2.4 (8)

3.6 (12)

12 (40)

15 (50)

18 (60)

21 (70)

B

A

A

A

C

C

C

C

C

C

C

C

L : LONG ANGLE

DISTANCE

HEIGHT

1.5 (5)
2.4 (8)

3.6 (12)

24 (80)

30 (100) 36 (120) 45 (150)

B

B

A

A

C

C

C

C

C

C

C

C

m (ft.)

CAUTION

W

W

L

A

B

C

Lens Holder

Lens

WIRING

5

Power wires should not exceed the following lengths.

VOLTAGE

WIRE SIZE

AWG 22 (0.33 mm

2

)

12 V

14 V

520 m (1700 ft)

1130 m (3700 ft)
1780 m (5830 ft)
2850 m (9350 ft)

820 m (2690 ft)

1310 m (4290 ft)

AWG 20 (0.52 mm

2

)

AWG 18 (0.83 mm

2

)

TAMPER

(N.C.)

ALARM

OUTPUT

(N.C.)

POWER INPUT

(9.5 to16 V DC)

SPARE

Connect tamper terminals to

a 24 hour supervisory loop.

● 

When using two or more units on one wire, the maximum length is 

obtained by dividing the maximum wire length listed above by the 

number of units 

used.

< How to remove PCB >

< How to open knockouts >

< How to change the lens type >

Note>>

When you remove the PCB, push 

down on the hook under PCB and 

remove it from its base. Attachment 

of PCB isthe reverse of removal. 

Loosen fastening screw and 

remove cover.

Conduct a walktest and make 

adjustments (Section 7).

1. Open the cover's hook and then 

lens cover can be removed.

 

2. 

Remove lens holder carefully. 

Select wide angle or long range 

according to Section 6-2. 

(Note: Factory default is WIDE 

ANGLE.)

3. 

Check to confirm that the lens is 

in the desires position. Press 

down the lens holder until it clicks 

into place along the guide of 

cover. Fix the screw at the end.