Frequently Asked Questions (FAQ’s)
All rights reserved by OPTEX Co., Ltd.
P.9
MP-4 (Optional kit)
Metal Plates
Tamper Bushings
Q-17: Can I mount AX-TFRs on walls, poles or in towers?
A-17: Yes, you can. It is also possible to mount two AX-TFRs on a same pole,
back to back. When you mounting an AX-TFR in a beam tower, an optional
unit
“
MP-4
”
(indicated in a picture below) is required. MP-4 includes tamper
bushings for LED termination.
Important notes:
> The switch selection cannot be recognized with the tamper bushing
inserted. Remove the tamper bushing before selecting a function using the
switch.
> After completion of the settings, be sure to insert a tamper bushing and
please check that all LEDs are turned OFF.
> Monitor Jack Output becomes disabled when tamper bushing inserted.
> When inserting the tamper bushing, reception indicators for beam
alignment will be disabled. Please complete the alignment tuning before
inserting the tamper bushing.
[For installation instruction, please refer to P.3-7 of the instruction manual.
P.12: SPECIFICATION describes more about the MP-4.]
Wall mount
Pole mount
(Single detector)
Pole mount
(Two detectors)
Tower in-mount
MP-4 (Option)
required