background image

9

• Specifications and designs are subject to change without prior notice.
• These units are designed to detect an intruder and activate an alarm control panel.

Being only a part of a complete system, we cannot accept responsibility for any 
damages or other consequences resulting from an intrusion.

- Specifications

Others

Detection method

Detection area

Mounting height

Mounting mode

Sensitivity

Detection speed

LED indicator

Alarm cycle

Battery saving timer

Alarm output

Tamper switch

Warm-up time

Power supply

Current

PIR sensitivity

Weight

Operation temprature

Operation humidity

Location

Dimensions

Passive infrared

 

N.C. 28 V DC 100 mA max.

The contact opens once the casing is detached. 

Approx. 60 s

H/ M/ L

< 95%

Indoors

 

Model

AP-360BR(C)

Warm-up upon power on: blinking

Stand-by: off

Walk test: solid on

Alarm: off

Approx. 2 s

120 s/ 5 s selectable

N.O./N.C., 3.6 V DC 10 mA max.

2.7 to 3.6 V DC (CR123A battery)

3 V DC

Stand-by: 10цA, Max.: 4 mA

ø6 m (ø20’ at mounting height: 4.5 m (14’9” ft.)

2.5 to 4.5 m (8’2” ft. to 14’9” ft.)

2.0

 at 0.6 m/s (3.6°F at 2’/s)

0.3 to 3.0 m/s (1‘/s to 9’10”/s)

50 g (1.76 oz)

-20 to +50

 (-4°F to +122°F)

86 x 86 x 42.5 mm (3.39 x 3.39 x 1.67 in.)

: with 86-type box mount

ø52 x 42.5 mm (ø2.05 in. x 1.67 in.)

: without switch box mount

Recessed ceiling mount/86-type box mount

Summary of Contents for AP-360BR

Page 1: ...Specifications Dimensions Detection area Troubleshooting Timing chart Compliance Before installation Others Contents Page 2 3 Installation Ceiling mount without switch box Wiring 2 Ceiling mount with...

Page 2: ...cause injury and or property damage Check mark indicates recommendation Nix sign indicates prohibition Special attention is required to the section of this symbol Mounting height 2 5 to 4 5 m 8 2 to 1...

Page 3: ...cations 3 Top cover Lens Base cover JP2 PIR sensitivity JP1 Alarm output mode SW1 Tamper switch Accessories Retaining spring x 2 Fixing screw Mounting Bezel for an 86 type box Screw cap x 2 JP3 Batter...

Page 4: ...rees to prevent interference with the casing Jumper pin settings Assemble Close the base cover and fasten the screw to fix the cover JP1 Alarm output mode JP2 PIR sensitivity 1 2 3 120 s default 5 s J...

Page 5: ...retaining spring 1 2 3 Mount the detector on the ceiling Be sure to arrange the wires with a downward slope to prevent water igress into the detector 1 4 2 3 Insert the detector into the hole with th...

Page 6: ...ccessories used in this installation Mounting Bezel for an 86 type box Screw cap x 2 Options to procure in the market 86 type box x 1 or 2 Screw x 2 1 Prepare an 86 type box on the ceiling Install the...

Page 7: ...7 2 3 Wiring 1 Red 2 Black 3 White 4 Yellow 5 Green 6 Blue Power supply positice Power supply negative Alarm output Alarm output Tamper output Tamper output Alarm Tamper Transmitter...

Page 8: ...8 Power on Wait for 60 seconds to complete the warm up time Walk in the detection area to check the detecting performance 3 1 Walk test 3 Checking 1 2 3 Start operation 4 Power 60 sec...

Page 9: ...tivity Weight Operation temprature Operation humidity Location Dimensions Passive infrared N C 28 V DC 100 mA max The contact opens once the casing is detached Approx 60 s H M L 95 Indoors Model AP 36...

Page 10: ...2 0 6 7 1 0 3 3 0 1 0 3 3 2 0 6 7 3 0 9 10 Mounting height Detection area Maximum detection area 2 5 8 2 3 3 10 10 3 0 9 10 4 0 13 1 3 5 11 6 4 6 15 1 4 0 13 1 5 4 17 8 4 5 14 9 6 0 20 Unit m ft in 3...

Page 11: ...ange the detector location Remove the heat source fron the detection area or change the detector location Check the output load Repair or replace the damaged part Connect the wires for the detector co...