FocusLynx TEC with QuickSync
199 Smith Street · Lowell, Michigan 49331 · U.S.A.
Telephone: 616-897-9351 · Fax: (616) 897-8229 · Toll Free: 888-488-0381
FocusLynx QuickSync TEC Installation Instructions - Revision 1
Page 6 of 10
Step 6
With the gold knob still loose, disengage the motor by rolling the motor cap down about 30 to 40-
degrees (about 1/8
th
of a turn). The clamp
should hold the motor assembly in place.
Now rotate the original black knob on the
opposite side of the focuser, ensuring the
gold knob is centered and does not rub
against the housing.
Step 7
Use the long 1/16” hex key to tighten the
setscrew inside the gold knob against the brass
expansion collar. Rotate the black knob to
confirm the gold knob moves freely.
When satisfied with the feel, tighten the setscrew in the gold knob securely. It is important to tighten
firmly so that the brass expansion collar does not unscrew during typical usage. You should take care to