3. Sensor
Adjustments
RFX
The Sensor is already setted for a medium sensitivity that covers most of the installations, but if
you want to increase or decrease the sensitivity of the Active and / or the Passive sensor to make
the installation PET IMMUNE , you can adjust the 2 PARAMETERS separately from 1 (max) to 10
(min) of the sensitivity of the active and passive part. In this case remove the front of the box and wait for
abo about 30 seconds, then proceed as follows :
a) PRESS the PROG button twice quickly, the Red LED shows the sensitivity already setted for the active
and the yellow LED for the passive one . Hold down the button, the Red LED starts to BLINK ,
release the button after the desired number of flashes, THEN the setted number of flashes it is
repeated, then pressing again the PROG button starts to BLINK the Yellow LED, release the button
after the desired number of flashes then the setted number of flashes it is repeated .
b)
From 1 to 10, more flashes correspond to a lower SENSITIVITY. .
c)
At the end of the settings
wait about 10 seconds and close the plastic cover
d)
Secure the cover
with the supplied screw and cover it with the screw cover
e)
Wait for about 30 seconds
and go through the pass to verify the ALARM condition
f)
When the passive sensor "sees" a passage, the Yellow LED lights up , the Red LED lights up when the alarm is
triggered, after every alarm transmission the Sensor enters an halt condition for about 5 seconds .