Optea RFX B User Manual Download Page 3

3.  Sensor  

Adjustments 

 

RFX

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                                                                                                                                  

                                                                                                                          

 

The Sensor is already setted for a medium sensitivity that covers most of the    installations, but   if  
 you want to increase or decrease the sensitivity of the Active and / or the Passive sensor  to make  
 the installation  PET IMMUNE , you can adjust the 2 PARAMETERS separately from 1 (max) to 10 

(min) of     the sensitivity of the active and passive part. In this case remove the front of the  box  and wait for 
abo           about 30 seconds, then proceed as follows  :  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

     a)    PRESS the PROG button twice quickly, the Red LED shows the sensitivity already setted for the active 
             and the yellow LED for the passive  one . Hold down the button, the Red LED starts to BLINK ,  
             release  the button  after the desired number of flashes, THEN the setted  number of flashes it is   
             repeated, then   pressing again the PROG button starts to  BLINK  the Yellow LED, release  the button   
             after the  desired  number of    flashes  then  the setted  number of flashes it is  repeated . 

 

b)

 

From 1 to 10, more flashes correspond to a lower  SENSITIVITY. . 

 

c)

 

At the end of the settings 

wait about 10 seconds and  close  the plastic cover 

 

d)

 

Secure the cover

  with the supplied screw and cover it with the screw cover

 

 

e)

 

Wait for about 30 seconds 

and go through the pass to verify the ALARM condition

 

 

f)

 

When the passive sensor "sees" a passage, the Yellow LED lights up , the Red LED lights up when the alarm is 
triggered, after every  alarm transmission the Sensor enters  an halt condition for about 5 seconds .

 

Summary of Contents for RFX B

Page 1: ...ive Infrared Passive Infrared Alarm and Tamper Outputs by solid state relays N C RFX B M CURTAIN SENSOR USER MANUAL OPTEA s r l Via Saragat 14 40062 Molinella BO ITALY Tel 39 051 665 00 71 Fax 39 051 665 00 28 Siti internet www optea it www optea lift com ...

Page 2: ...he wall at 1 cm to Sx or Dx from the center of the long side of the sensor by making an hole by the drill c Put anti remove jumper onto ON if the magnet is plugged in otherwise in OFF position no Anti remove function setted d Fix the SENSOR using the 2 dowells supplied of 5mm by the 2 holes on the sensor sides e Connect Tamper and Alarm OUTPUT N C contacts and the power supply 12V GND f Close the ...

Page 3: ...he button the Red LED starts to BLINK release the button after the desired number of flashes THEN the setted number of flashes it is repeated then pressing again the PROG button starts to BLINK the Yellow LED release the button after the desired number of flashes then the setted number of flashes it is repeated b From 1 to 10 more flashes correspond to a lower SENSITIVITY c At the end of the setti...

Page 4: ...logy RFX sensor exploits the benefits of active infrared technology which allows you to generate a signal and synchronously detect changes and passive infrared technology that is useful for detecting hot moving bodies and helps to discriminate things from people animals ACTIVE technology generates a very narrow infrared beam that limits the detection range to the minimum necessary avoiding FALSE I...