background image

POE power surge protector 

network signal series Product 

Manual

 

 

Do  check  t he  sur ge  pr ot ect or   bef or e  i nst al l at i on  t o  pr event   f r om 

unnecessar y  i nj ur y.   I f   t he  sur ge  pr ot ect or   i s  wi t h  any  def ect s,   i t  

shal l   not   be  i nst al l ed.

 

  Do  use  t he  sur ge  pr ot ect or s  i n  accor dance  wi t h  t he  condi t i ons 

speci f i ed  i n  t he  t echni cal   t abl es.   Exceedi ng  t hei r   l i mit s  may  cause 

damage  t o  t he  pr ot ect or   i t sel f   or   even  t o  equi pment .

 

  Do  f ol l ow  t he  r el evant   st andar ds  and  r ul es  when  i nst al l i ng.   Thi s 

sur ge  pr ot ect or   must   be  i nst al l ed  by  qual i f i ed  per sonnel   who  have 

obt ai ned  t he  r el evant   cer t i f i cat e  bef or e  t he  el ect r oni c  equi pment   t o  be 

pr ot ect ed.

Technical 
Parameter

s

Model           

ZZRJ45(POE)/ZZRJ45-K(POE)

Number of protection roads

1 road or 24 road

Category

Power 

Network

Nominal operating voltage Un

48V

5V

Maximum continuous 

operating voltage  Uc

60V

6V

Nominal discharge current

8/20

μ

S

In

L-L:1kA

L-L:300A

L-PE:2.5kA

Voltage protection level Up

 150V

L-L

 35V (L-L)

 600V(L-PE)

300V(L-PE)

Response time tA

1ns

Transmission rate Vs

100/1000Mbps

Insertion loss a

E

0.5dB

Temperature range

-40

…+85

Protection line---

 1/2

3/6 data

4/5

7/8 power

1/2

3/6 power 1/2

3/6

4/5

7/8 data

Interface Type

RJ45

Shell material

Shielding metal

Dimensions

94x38x28mm

19 "rack

Degree of protection

IP20

 

     

Sui t abl e  LPZ1- LPZ3  Boundar y,   i nst al l ed  i n  a  var i et y  of  

communi cat i on  l i ne  +  power   suppl y,   power   suppl y,   such  as  Et her net ,  

wi r el ess  br i dge,   wi r el ess  AP,   net wor k  camer as,   so  t hat   f r om 

l i ght ni ng  i nduced  vol t age,   vol t age  f l uct uat i ons  i nt er f er ence,  

el ect r ost at i c  di schar ge,   and  l ar ge  l oad  st ar t   maj or   damage  t o  t he 

sur ge  vol t age  gener at ed  caused.

      The  i nt er f ace  i n  t he  f or m of   RJ45,   t he  pr oduct   i s  di vi ded  i nt o 

Fast   and  Gi gabi t   POE.   Thi s  pr oduct   has  a  t hr ough- f l ow  capaci t y,  

r esi dual   vol t age,   f ast   r esponse,   at t enuat i on,   conveni ent  

i nst al l at i on.

Scope of 

application

Installation 

diagram

Installation and 

maintenance

1.   POE  power   ser i es  net wor k  si gnal   sur ge  pr ot ect or   can  be  i nst al l ed  i n  LPZ0- 1 

ar ea  t o  be  pr ot ect ed  or   di r ect l y  on  t he  devi ce  ( or   syst em)  f r ont   end,   f r om t he 

devi ce  ( or   syst em)  t o  be  pr ot ect ed  when  i nst al l i ng  t he  cl oser   t he  bet t er .

2."I N"  connect s  t he  i ncoming  l i ne,   "OUT"  connect s  t he  pr ot ect ed  devi ce  ( or  

syst em).   "L  /   +"  connect s  t he  power   ear t h  l i ne  or   power   suppl y  l i ne,   "N  /   - " 

connect s  t he  power   suppl y  neut r al   or   t he  power   suppl y  negat i ve  l i ne.   When 

i nst al l i ng,   bot h  ends  of   t he  l i ne  must   be  l ai d  separ at el y,   not   t i ed  t oget her   t o 

pr event   f r om t he  secondar y  i nduct i on  phenomenon.

3.The  sur ge  pr ot ect or   gr ound  l i ne  must   be  as  shor t   as  possi bl e.

4.The  sur ge  pr ot ect or   does  not   r equi r e  l ong- t er m mai nt enance  under   t he 

condi t i ons  of   i nst al l at i on,   onl y  r out i ne  mai nt enance.   I f   t he  si gnal   t r ansmissi on 

i s  wi t h  pr obl ems,   r epl ace  a  new  sur ge  pr ot ect or   and  si gnal   t r ansmissi on  back  t o 

nor mal .   I t   i ndi cat es  t hat   t he  sur ge  pr ot ect or   has  been  damaged,   need  r epai r ment  

or   r epl acement .

We are professional in manufacturing power surge protector, signal surge 

protector, antenna-fed surge protector, lightning rod.

Reviews: