Opop Biopel 10 Installation Manual Download Page 3

Automatic boilers – OPOP pump groups

 

 

 

1.

 

PACKAGING 

Pump  group  is  packaged  in  a  assembled  state,  ready  for  installation  on  the  boiler.  The  package  includes  the 
following components: 

 

Grundfos pump auto-ADAPT 

 

Thermostatic valve 55°C 

 

Safety valve 

 

2 pcs thermowells for temperature sensors 

 

2 pieces of fittings for connection to the boiler (water inlet and outlet) 

 

Fitting for connecting the inlet valve 

 

2 pieces of fittings for connecting the heating circuit (water input and output) 

 

Connecting cable for the bumb and boiler 

 
 

2.

 

LABELING 

OPOP  company  sells  to  its  automatic  boilers  several  versions  of  the  pump  groups.  Group  type  associated  with  a 
particular type of boiler, on which the pump goup will be mounted. According to the designation of the pump, check 
if given pump group is compatible with the type of boiler.  

 

Gourp pump version 

Boiler type 

Group pump Biopel 10-30 

10kW, 15kW, 20kW, 30kW 

Group pump Biopel 40 

40kW 

 

3.

 

MOUNTING 

Below is a mounting diagram that illustrates the connection of the pump to the boiler itself. When installing, check 
all connections are tight so as to prevent the escape of water from the heating system. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical 
connection 

Thermowell 

Water outlet 
G1 ¼“M 

Water inlet 
G1 ¼“M 

Pump 

Thermostatig valve 
55°C 

Filling valve 

Thermowell 

Summary of Contents for Biopel 10

Page 1: ...nection to the heating system The pump groups are equipped with thermostatic valve and pump so this guarantees the boiler protection against low temperature corrosion This manual serves plumber for in...

Page 2: ..._____________ 2 3 Mounting _______________________________________________________________________ 2 4 Technical specification _____________________________________________________________ 3 5 Warrant...

Page 3: ...NG OPOP company sells to its automatic boilers several versions of the pump groups Group type associated with a particular type of boiler on which the pump goup will be mounted According to the design...

Page 4: ...nu of boiler s control unit 4 TECHNICAL SPECIFICATIONS Max system pressure 2 bar Heating water temperature 2 a 110 C Electrical protection IP 42 Voltage 1 x 230 V 50 Hz Max pumping power 3 m3 h EEI En...

Page 5: ...of combustible vapors or gases into the boiler room or during works with temporarily developed fire or explosion danger gluing the floorings painting with combustible paints etc boiler must be put out...

Page 6: ...Connection of electrical devices and appliances SN 34 0350 Electrical regulations Regulations for mobile connections and wiring management SN EN 60 079 10 Electrical regulations Regulations for elect...

Page 7: ...n normal condition according to the Instruction manual boiler and all additional devices are installed and operated in accordance with standards and laws in given State is connected to a chimney accor...

Page 8: ...ovsk 750 757 01 Vala sk Mezi Bank details Komer n banka a s account no 1608851 0100 Reg no 47674105 VAT no CZ 47674105 Phone Sales Dept 571 675 589 Secretariat 571 611 250 Production 571 675 405 Sour...