CAUTION!
To maintain specified performance and retain certain operating
characteristics, RF input power should not 10 dBm.
3.7. Operation
3.7.1 ON/OFF
Switch
In the ‘ON’ position, AC power is supplied to the power amplifier.
3.7.2 ON/OFF Switch Lamp
Lights to indicate the distribution of AC power throughout the power
amplifier.
3.7.3 TEMP. FAULT Indicator
Lights at an internal temperature exceeding 80º C with the amplifier
turning off DC bias voltage to the main amplifiers’ modules. DC bias
voltage will automatically return at temperatures below 75º C.
3.8 Turn
Off.
WARNING!
In the event of ANY power failure, whenever possible and practical, it is
advisable to reset the ON/OFF switch on the front panel to the “OFF”
position before you reconnect AC power to the power amplifier. This is to
prevent any possible electrical damage to the amplifier, due to the initial
power surge, once power is restored.
Turn off the RF power amplifier by first lowering or removing the RF Input drive
level and then placing the ON/OFF switch in the ‘OFF’ position.