3

  |  

Opera Beds

 

Serene Mattress User Guide and Technical Specifications | Version 3

The Opera

  

Serene Profiling Mattress is a medical device intended to be 

used with care beds in residential homes, nursing homes and the domestic 
environment as a pressure redistribution mattress. The mattress is intended 
to be used by occupants* weighing up to 29st 1lb/185kg. 
The mattress is designed to be used to prevent the development of pressure 
ulcers in occupants in the high risk** category, but it may also be used for 
lower risk categories. The mattress may also be used as a mattress to sleep, 
rest on and to receive care from.
The mattress can be used in conjunction with profiling care beds, including 
the Opera

 

Classic Profiling Beds, the Signature Profiling Beds and the Solo 

Profiling Bed collections. Before using the mattress with a care bed, confirm 
that the mattress specifications meet the requirements of the care bed. 

If the mattress used does not meet the care bed requirements, entrapment 
and injury may occur. The mattress may also be used with mattress underlays 
and fall prevention systems, always conduct a risk assessment when using 
the mattress with other products. Using the mattress with the wrong bed may 
void the warranty terms and conditions.

**The mattress may be used by adults, the elderly and children, subject to a clinicians guidance. The mattress is not intended 
to be used by young children or as a cot mattress.

A no

n-intended use is a use that deviates from the intended purpose and is 

not outlined in the Instruction Manual.

Non-intended uses include, but are not limited to the following:

• 

Loading the mattress beyond the maximum user weight (29st 1lb/185kg).

• 

Using the mattress with any devices that will compromise the general 

safety and performance requirements of the mattresses.

• 

Modifying the mattress or mattress cover.

2.

 User Instructions

2.2

 Non Intended Uses

2.1

 Intended Uses

*Indication of use based upon interface pressure readings, this is not a prescriptive criteria. Always defer to a clinicians 
judgement, and advice.

Summary of Contents for Serene Profiling

Page 1: ...Serene Profiling Mattress User Guide and Technical Specifications operabeds com 0333 222 8584...

Page 2: ...and Technical Specifications Version 3 1 Explanations of Symbols 2 2 User Instructions 3 3 Maintenance and Inspections 5 4 Safety Instructions 8 5 Technical Specifications 10 6 Guarantee 12 7 Opera Wa...

Page 3: ...rective 93 42 EEC This product must be disposed of in a separate refuse collection in the European Union Do not dispose of as normal domestic waste Maximum patient weight Refer to instruction manual T...

Page 4: ...mattress used does not meet the care bed requirements entrapment and injury may occur The mattress may also be used with mattress underlays and fall prevention systems always conduct a risk assessmen...

Page 5: ...rayed edging Make sure that once unrolled that the cover seams sit correctly to the edges of the mattress and that the three zips are fully closed If the mattress cover is compromised do not use it as...

Page 6: ...tress when replacing ensure that the outer cover is on the outside and not the inside Non compliance may result in compromising the functions of the cover this includes the antimicrobial water resista...

Page 7: ...sure damage to the user For further information on how to inspect and audit the mattress please refer to the following Mattresses Prevention of Cross Infection MDA SN 1999 31 Mattress surface Figure 1...

Page 8: ...catch the mattress cover To disinfect in situ use a 0 1 sodium hypochloride solution 1 000 ppm chlorine Do not use biological or phenolic based cleaners Removable contaminated covers should be launde...

Page 9: ...e mattress should be withdrawn from use immediately if the foam and cover are compromised the mattress and cover should be withdrawn from use immediately and replaced Failure to withdraw the mattress...

Page 10: ...e surfaces etc Do not drag mattresses failure to observe this may result in compromising the cover and foam mattress The mattress is not designed for use in a mental health facility or by those at ris...

Page 11: ...rn cycles 4 Warranty 1 year Mattress Cover Multi stretch cover with white substrate Yes Antimicrobial cover Yes Tested in a group test against Aspergillus niger Staphylococcus aureus Moisture Vapour P...

Page 12: ...Prevention Risk Category High Risk 5 3 Storage and Transport Storage and Transport Conditions Store the mattress in a dry dark clean environment do not store near heating appliances such as radiators...

Page 13: ...elivery or deemed delivery of the product 7 1 2 This contractual product warranty does not operate to limit rights under the statutory warranties referred to in clause 7 3 1 below 7 2 Warranty Conditi...

Page 14: ...t at Operas election This credit or refund will be for the amount of the purchase price of the product excluding the associated delivery cost 7 2 6 In the event that a replacement refund or store cred...

Page 15: ...ally configured by Opera f To any failure to the extent that the failure is not a failure of the product to perform in accordance with its specifications g To service of any product whilst it is outsi...

Page 16: ...Opera Beds Azure House Connaught Road Kingswood Hull HU7 3AP 0333 222 8584 support operabeds com operabeds com Version 3 Published June 2021...

Reviews: