User Manual
Chapter 2 Card Installation and Configuration
1.
Hardware Installation and Setup
1)
Configure the Jumper Settings
Please refer jumper setting for details. To install B800P, user should
follow these steps.
A.
Setting Card ID Switch
User should take care of the card id switch, if the user wants to
install more than one cards of B800P in one pc. The user should follow
these produces:
1.
The card id of the first card must be set to 0, and the second card
should be set to 1, and so on.
2.
The first card is a card that will be initialized (i.e installing
driver) first when system is booting.
3.
At most of cases, Linux will initialize PCI devices according to
PCI slot order. The slot is nearest to the CPU will be initialized
first; the slot at the far end from CPU will be initialized at last.
That is to say that if user has more than one cards of B800P in pc,
the one is nearest to CPU should be set to card id 0.
4.
For more details about Card ID, please check F&Q section.
B.
Adjusting Termination of S/T Interface (100 ohm)
1.
If a port works on NT mode, user should set jumper to CONNECT (ON).
2.
If a port work on TE mode, Theoretically it should be to OPEN(OFF),
but user might connect to some non-standard isdn terminal
equipments that do not have terminal resistors, for such equipments,
you should set it to CONNECT(ON).
C.
Power Feeding Connector
These jumpers control whether the card will feed power to the external
isdn terminal. User should adjust accordingly from the following:
If the port works on TE mode, user MUST set the jumper to
OPEN(OFF)
If this port will work on NT mode, the ISDN terminal requires
ISDN power supply, user should set the jumper to CONNECT(ON).
ISDN terminal does not require ISDN power supply, user should
set the jumper to OPEN(OFF).