Chapter 2 Card Installation and Configuration 

 

1.

 

Hardware Installation and Setup 

1)

 

Configure the Jumper Settings 

Please refer jumper setting for details. To install B800P, user should 
follow these steps.  

A.

 

 Setting Card ID Switch 

User should take care of the card id switch, if the user wants to 
install more than one cards of B800P in one pc. The user should follow 
these produces: 

1.

 

The card id of the first card must be set to 0, and the second card 
should be set to 1, and so on. 

2.

 

The first card is a card that will be initialized (i.e installing 
driver) first when system is booting. 

3.

 

At most of cases, Linux will initialize PCI devices according to 
PCI slot order. The slot is nearest to the CPU will be initialized 
first; the slot at the far end from CPU will be initialized at last. 
That is to say that if user has more than one cards of B800P in pc, 
the one is nearest to CPU should be set to card id 0. 

4.

 

For more details about Card ID, please check F&Q section. 

  

B.

 

 

Adjusting Termination of S/T Interface (100 ohm) 

1.

 

If a port works on NT mode, user should set jumper to CONNECT (ON). 

2.

 

If a port work on TE mode, Theoretically it should be to OPEN(OFF), 
but  user  might  connect  to  some  non-standard  isdn  terminal 
equipments that do not have terminal resistors, for such equipments, 
you should set it to CONNECT(ON). 

 

C.

 

 

Power Feeding Connector 
These jumpers control whether the card will feed power to the external 
isdn terminal. User should adjust accordingly from the following:  

—

 

If the port works on TE mode, user MUST set the jumper to 
OPEN(OFF) 

—

 

If this port will work on NT mode, the ISDN terminal requires 
ISDN power supply, user should set the jumper to CONNECT(ON). 

ISDN terminal does not require ISDN power supply, user should 
set the jumper to OPEN(OFF).

 

 

 

VoIPon      www.voipon.co.uk      [email protected]      Tel: +44 (0)1245 808195       Fax: +44 (0)1245 808299

Summary of Contents for B800P

Page 1: ...Effective Asterisk Cards OpenVox B800P User Manual for mISDN Written by James zhu Email james zhu openvox cn zhulizhong gmail com Date 15 10 2007 Version 0 01 VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Page 2: ...86 755 82535362 82535095 Fax 86 755 82535174 E Mail sales openvox com cn IM for Sales betty_yljiang hotmail com rubyzhang1217 hotmail com IM for Technical Support support openvox com cn zhulizhong gmail com zhulizhongum hotmail com Business Hours 9 30AM 17 30PM from Monday Friday URL www openvox com cn Thank You for Choosing OpenVox Products VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245...

Page 3: ...User Manual Table of Contents Chapter 1 Overview 4 Chapter 2 Card Installation and Configuration 6 VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Page 4: ...Spec 2 2 for 3 3V and 5V signal environments DTMF detection on all B channels Multiparty audio conferences bridge Onboard power feeding for 8 NT Ports PCM bus connectors daisy chaining Each of the 8 ports can be individually configured for TE or NE mode Full software and hardware compatible with Junghanns NET Bristuff driver and mISDN driver Application ready use Asterisk to build your IP PBX Voic...

Page 5: ...kSetup gif Asterisk provides Voicemail services with Directory Call Conferencing Interactive Voice Response Call Queuing It has support for three way calling caller ID services ADSI IAX SIP H 323 as both client and gateway MGCP call manager only and SCCP Skinny voip info org VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Page 6: ...ser has more than one cards of B800P in pc the one is nearest to CPU should be set to card id 0 4 For more details about Card ID please check F Q section B Adjusting Termination of S T Interface 100 ohm 1 If a port works on NT mode user should set jumper to CONNECT ON 2 If a port work on TE mode Theoretically it should be to OPEN OFF but user might connect to some non standard isdn terminal equipm...

Page 7: ...efer jumper setting section for the detail 5 Plug back the AC power cable and power on PC If user wants to know the details about hardware configuration of B800P please refer hardware setting section 2 Software Installation and Setup B800P supports original mISDN driver form http www misdn org index php Installing_mISDN Customers can download it from that URL There are few steps to install the dri...

Page 8: ...nstall gcc yum install gcc c 3 Downloading unzipping and compiling driver A Download the stable version of mISDN mISDNuser chan_mISDN and asterisk drivers from http www misdn org index php Installing_mISDN and copy the tar file to usr src Here we are using mISDN 1_1_2 and mISDNuser_1_1_2 User can get more details from mISDN org B Download OpenVox patch called hfc_multi c from www openvox com cn It...

Page 9: ...rnel source user must create link linux 2 6 under usr src There are many files under usr src please check D Compiling mISDN mISDNuser chan_mISDN and asterisk cd usr src mISDN 1_1_2 make make install std2kern cd usr src mISDN 1_1_2 make make install VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Page 10: ...ent chan_misdn with asterisk E Modifying and loading modules for mISDN Execute mISDN scan Please take note here 1 B800P uses different chip the setting will be different from B200P 400P The command mISDN start will generate an incorrect misdn conf under etc To solve that problem user has to edit the mISDN from usr sbin directory Please make sure the options with different setting modes is meet the...

Page 11: ...ion is shown as follow The type should be 0x08 for B800P with 1 NT mode and 7 TE mode The layermask should be 0x3 0xf 0xf 0xf 0xf 0xf 0xf 0xf 2 Starting mISDN Execute mSIDN start vi etc mISDN conf the part of it looks like this Execute load chan_misdn so in asterisk console VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Page 12: ...n conf and extensions conf are shown as follow The console shows that user calls to SIP and makes outbound call by using ISDN ISDN phone VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Page 13: ...ing ping assignments and references please check from http www openvox com cn downloadsFile 1194838660 pdf Some Concerns 1 LEDs will turn into green and blink if the drivers are loaded 2 Misdn show channels commands show nothing 3 When calls coming the LED will be turned into green status for very short while VoIPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 ...

Reviews: