Opengear ACM5004-G Quick Start Manual Download Page 3

           ACM5000-G Quick Start (520027-Rev 1.7) 

Page 3

 

Note:

 

Your GSM carrier may have provided you with connection details. However, you 

generally will only need to enter your provider’s APN and leave the other fields 

blank. If provided a Pin Code you may need to use it to unlock the SIM card. 

You may also need to use alternate DNS servers from those provided by your carrier:  

 

Enable 

Override DNS

. Then check the 

Override returned DNS Servers 

box 

and enter the IP of the DNS servers into the spaces provided. 

 

Check 

Apply 

and a radio connection will be established with your cellular carrier. 

Out-of-band access is enabled, so the cellular modem connection is always ON.  

 

Verify the 

Connection Status in the 

Statistics - Failover& Out-of-Band

 tab is 

shown as 

Connected. You can also check your allocated IP address

 

 

You  can  measure  the  received  signal  strength 

RSSI  from  the 

Cellular 

Statistics

 page on the 

Status: Statistics

 screen.  -99 dbm to –90 dbm = Weak 

Coverage,  -89 dbm to – 70 dbm = Medium, -69 dbm or greater = Strong

 

Note:

 You can also see the connection status from the WWAN LED. OFF is shown when in 

reset mode or not powered. When powered, it will go ON and while searching for 
service  it  will  flash  off  briefly  every  5sec.  Once  a  radio  connection  has  been 

established  with  your  cellular  carrier  (ie,  after  an  APN  has  been  properly 

configured) the WWAN LED will blink at a rate proportional to traffic signal strength 
detected i.e. OFF =Low, Blinking Slow = Low to Medium Blinking Fast = Medium to 

High and ON=Strong

 

Step 5   OoB access

   

To directly access the ACM5004-G, it needs a Public IP address and must not have SSH 
access  firewalled.  Almost  all  carriers  offer  corporate  mobile  data  service/plans  with  a 

Public (static or dynamic) IP address. These plans often have a service fee attached. 

 

If you have such a static Public IP address plan, you can now try accessing the 

ACM5004-G  using  the  Public  IP  Address  provided  by  the  carrier.  However,  by 

default, only HTTPS and SSH access is  enabled on the OoB connection. So you 
can browse to the ACM5004-G, but you cannot 

ping it 

 

If you have a dynamic Public IP address plan, then a DDNS service will need to 
be configured. Once this is done, you can then also try accessing the ACM5004-G 

using the allocated domain name  

By  default,  most  providers  offer  a  consumer  grade  service  which  only  provide  dynamic 

Private IP address assignments  to 3G devices.  This  IP address is not  visible across  the 
Internet but generally it is adequate for home and general business use.  

 

With such a plan, the

  Failover &  Out-of-Band

 tab on the 

Status:  Statistics 

page,  will  show    your  carrier  allocated  a  Private 

IP  Address  (i.e.  in  the  range 

10.0.x.x, 172.16.x.x or 192.168.x.x) 

 

For an inbound OoB connection with such a plan, you will need to use Call Home 

with a VCMS/CMS6110 or set up a VPN connection 

In this default 

out of band access mode

, the connection to the carrier cellular network 

is  always  on  -  awaiting  any  incoming  access  to  the  ACM5004-G  or  attached  serial 
consoles/network hosts.  

An alternative is 

failover  mode.

 This  will tell  the internal cellular connection  to remain 

idle in a low power state. Only when primary and secondary probes are not successful will 
it connect to the cellular carrier (refer to the User Manual) 