OpenEye Optix CM-525P User Manual Download Page 5

27104AF

5

COMPLIANCE STATEMENT 

 CE COMPLIANCE STATEMENT 

WARNING

THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY 
CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO 
TAKE ADEQUATE MEASURES.

THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES-003.

CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME NMB-003 

DU CANADA.

FCC INFORMATION

: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY 

WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF 
THE FCC RULES.  THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE 
PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS 
OPERATED IN A COMMERCIAL ENVIRONMENT.  THIS EQUIPMENT GENERATES, 
USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND 
USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL 
INTERFERENCE TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT 
IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH 
CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN 
EXPENSE.

CAUTION:

 CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE 

PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS AUTHORITY TO 
OPERATE THE EQUIPMENT.

Summary of Contents for Optix CM-525P

Page 1: ...Optix Pro Pack Dome Camera User Manual Please carefully read these instructions before using this product Save this manual for future use CM 525P model no pen Eye...

Page 2: ......

Page 3: ...LUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR LOSS OF BUSINESS INFORMATION EVEN IF OPENEYE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND WHETHER IN...

Page 4: ...QUALIFIED SERVICE PERSONNEL CAUTIONS RISK OF ELECTRIC SHOCK DO NOT OPEN EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol within a triangle is intended to alert the user to th...

Page 5: ...15 OF THE FCC RULES THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT THIS EQUIPMENT GENERATES USES AND...

Page 6: ...a dry cloth to clean the camera when it is dirty If it is hard to remove the dirt on the camera use a mild detergent and wipe it gently 6 Handle the camera with care Do not abuse the camera Avoid str...

Page 7: ...27104AF 7...

Page 8: ...ANCE STATEMENT CE COMPLIANCE STATEMENT IMPORTANT SAFEGURDS INTRODUCTION INSTALLATION CONFIGURATION PROGRAM OPERATION PTZ SETUP MENU TECHNICAL SPECIFICATIONS DIMENSIONS APPENDIX A TROUBLE SHOOTING APPE...

Page 9: ...27104AF 9...

Page 10: ...de 8 Auto Scan including Vector Scan 4 Pattern 240 Seconds 8 Privacy Zones 8 Alarm Inputs 4 Alarm Outputs NC NO Variable speed from 0 1 sec to 90 sec Turbo speed is Max 360 sec with Ctrl pressed Maxim...

Page 11: ...27104AF 11...

Page 12: ...Mount Bracket Joint Pipe Plastic Anchor Screws for Plastic Anchor L Wrench M4 L Wrench M5 Block Protector Cap Cable Alarm In Out Instruction Manual Silicon Rubber Sealant Teflon Tape 1 1 1 4 4 1 1 1 2...

Page 13: ...H 15 Out CH 16 Out 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SEN 2 INSTALLATION CONFIGURATION Figure 2 Basic Installation Diagram C BASIC CONFIGURATION ON OFF 1 CAMERA 75 TERM 16 1 2 3 4 5 6 7 8 9 10 11...

Page 14: ...allation of Pole Mount Wrap teflon tape around the joint pipe threads before attaching the Ceiling Mount Bracket and the Pipe Flange Seal the surface of the ceiling mount bracket with an bead of the s...

Page 15: ...end of line whether it be a dome camera or keyboard controller must have the cable for communication terminated by setting the appropriate DIP switch Without proper termination there is potentiaI for...

Page 16: ...through 9 To prevent damage each dome camera must have a unique address ID When installing multiple dome cameras using a multiplexer it is suggested that the dome camera address match the multiplexer...

Page 17: ...device other than a keyboard 2 INSTALLATION CONFIGURATION on 1 on 6 on 7 on 8 2 3 4 Protocol 5 Baud rate RS 422 485 NTSC PAL 2 1 3 4 Protocol OpenEye OPTIX P D Type P P Type Samsung ON OFF ON OFF OFF...

Page 18: ...S AL1 to 8 Alarm In You can use externaI devices to signaI the dome camera to react to events Mechanical or electrical switches can be wired to the AL Alarm In and GND Ground connectors See Chapter 3...

Page 19: ...me camera Once power is turned on the dome camera will start a configuration sequence When configuration is done the following information is displayed LOADING DOME ADDRESS 001 CHECKING EEP ROM INIT C...

Page 20: ...27104AF 20...

Page 21: ...en Menu Utility You can open the On Screen menu utility on your monitor by pressing the MENU KEY on the keyboard controller The following On Screen utility will appear A CONTROLLING THE ON SCREEN UTIL...

Page 22: ...CONFIG LANGUAGE EXIT AREA TITLE PRIVACY ZONE OSD DISPLAY VIEW ANGLE POSITION HOME PRESET AUTO SCAN TOUR PATTERN FOCUS WB CONTROL AE CONTROL LINE LOCK SCREEN SETUP DIGITAL EFFECT DAY NIGHT INIT DATA D...

Page 23: ...27104AF 23...

Page 24: ...HOME menu and enter the menu 2 You can select the Home Function by pressing the PST TOUR PTRN or SCAN button on your OpenEye Keyboard controller 3 After selecting the number move the function number E...

Page 25: ...tocol selection guide If you want to use other protocols consult with your local distributor Note If you want to go to the previous mode select the CLR ESC key To exit main MENU without saving select...

Page 26: ...A TITLE OSD DISPLAY VIEW ANGLE POSITION COOLER HEATER AREA TITLE SET UP NO 001 START PTZ 000 00 END PTZ 000 00 12345678 00 SAVE EXIT HOME SYS INFO DISPLAY DOME SETUP ALARMS OpenEye OPTIX PRE PACK CAME...

Page 27: ...Select No PRIVACY ZONE SETUP NO 001 MODE DISABLE 00 SAVE EXIT 12345678 Note ALL displays or titles will disappeared when you set all flags OFF C ON SCREEN DISPLAY OSD HOME SYS INFO DISPLAY DOME SETUP...

Page 28: ...Alarm Time Operation Title Preset AutoScan and Pattern Title Dome Mode T1 Tour1 001 Preset001 Flag Display Privacy Flip on Zoom Ratio When the camera is digital zoom you can see signal Pan Title Angl...

Page 29: ...y and or vertically The factory position is 33 05 Horizontal Vertical Variable 23 43 for horizontal 02 15 for vertical 4 PTZ SETUP MENU HOME SYS INFO DISPLAY DOME SETUP ALARMS OpenEye OPTIX PRE PACK C...

Page 30: ...ep the inside temperature of the OpenEye OPTIX Pre Pack at a stable operating condition If the temperature in the dome is to high the cameras Auto Mode will regulate the temperature by turning on the...

Page 31: ...preset menu each page can hold 80 presets A HOME PRESET 2 Title HOME SYS INFO DISPLAY DOME SETUP ALARMS OpenEye OPTIX PRE PACK CAMERA CONFIG LANGUAGE EXIT HOME PRESET AUTO SCAN TOUR PATTERN HOME PRES...

Page 32: ...sition and then pressing NO HOME button on your OpenEye keyboard controller HOME PRESET SETUP NO 001 FOCUS IRIS DWELL SEC PRESET AUTO AUTO 005 P 000 00 T 000 00 Z 001 00 01 02 03 04 05 06 07 SAVE EXIT...

Page 33: ...CUS SPEED PTZ START PTZ END PTZ DWELL SEC FOCUS IRIS ENDLESS LEFT 1 000 0 000 00 001 005 AUTO 1 Select No 00 0123456789 SAVE EXIT Note Press the SCAN button on your OpenEye Keyboard Controller to go d...

Page 34: ...0123456789 SAVE EXIT AUTOSCAN SETUP NO 001 MODE SPEED PTZ START PTZ END PTZ DWELL SEC FOCUS IRIS COMING GOING 1 000 0 000 00 001 000 0 000 00 00 005 AUTO 00 0123456789 SAVE EXIT 4 5 3 Start End AUTOS...

Page 35: ...O 001 SPEED FREEZE FAST OFF SAVE EXIT AUTOSCAN SETUP TITLE ABCDEFGHIJKLMNOP QRSTUVWXYZabcdefg h i j k l m n o p q r s t u v w x y z 0 1 2 3 4 5 6 7 8 9 SELECT CHARACTER MOVE TITLE POSITION CTRL KEY MO...

Page 36: ...ur NO 1 8 and press the TOUR button to call the Tour Tour Stop If you have a Joystick connected move the joystick anywhere to stop the function 6 7 TOUR SETUP NO 001 SPEED FREEZE TOUR1 FAST OFF 001 31...

Page 37: ...3 04 TIME 000 000 000 000 SAVE EXIT TITLE EDIT FOCUS OR IRIS KEY PRESS PTRN KEY TO LEARN 01 02 AUTOSCAN SETUP TITLE ABCDEFGHIJKLMNOP QRSTUVWXYZabcdefg h i j k l m n o p q r s t u v w x y z 0 1 2 3 4 5...

Page 38: ...ut 1 2 3 4 Off No Output Time Alarm will be held for programmed time 05 to 99 sec ALARM SETUP NO 01 02 03 04 05 06 07 08 PRI 2 1 1 1 1 1 1 1 MODE PT2 IN OFF OFF OFF OFF OFF OFF OFF OFF OUT OFF OFF OFF...

Page 39: ...l use MWB RED and MWBBLUE menus are controllable only in MWB AWC MODE is controllable only in AWC mode In MWB Manual WB or AWC mode 4 PTZ SETUP MENU FOCUS SETUP MODE AUTO SAVE EXIT HOME SYS INFO DISPL...

Page 40: ...Note USE INTERNAL mode for normal use If you use NTSC 60Hz or PAL 50Hz mode it is possible to utilize external mode If you are using NTSC 50Hz or PAL 60Hz it is highly recommended to use internal mod...

Page 41: ...ncy difference between the cycle of 50Hz fluorescent lighting and the vertical synchronization of the camera which causes the Flicker on a monitor The 50Hz power cycle of a fluorescent light causes a...

Page 42: ...f the GLOBAL key function is enabled 21 GLB will turn Off the Day Night 22 GLB will turn on the Day Night Mode HOME SYS INFO DISPLAY DOME SETUP ALARMS OpenEye OPTIX PRE PACK CAMERA CONFIG LANGUAGE EXI...

Page 43: ...cludes all stored data Titles Presets and Tours HOME SYS INFO DISPLAY DOME SETUP ALARMS OpenEye OPTIX PRE PACK CAMERA CONFIG LANGUAGE EXIT INIT DATA DOME RESET GENERAL INIT ALL FACTORY INIT CAMERA INI...

Page 44: ...SETUP MENU HOME SYS INFO DISPLAY DOME SETUP ALARMS OpenEye OPTIX PRE PACK CAMERA CONFIG LANGUAGE EXIT INIT DATA DOME RESET GENERAL RESET HOME OR ENT KEY CANCEL CLR ESC KEY HOME SYS INFO DISPLAY DOME S...

Page 45: ...exit the main menu select the CLR ESC key or select the MENU LOCK button 2 Exit the main menu by selecting EXIT mode 4 PTZ SETUP MENU HOME SYS INFO DISPLAY DOME SETUP ALARMS OpenEye OPTIX PRE PACK CAM...

Page 46: ...27104AF 46...

Page 47: ...SONY Super HAD CCD 752 H x582 V 470 460 lines NTSC PAL 360o continuous rotation 0 1o to 90o Proportional Zoom Turbospeed 360o sec maximum w ctrl pressed 360o sec maximum 0o to 90o User selectable to...

Page 48: ...enEye OPTIX Pro Pack Dome Camera Ceiling Pipe mm mm 5 9 150 1 1 4 NPT PIPE Thread 4 9 124 4 9 124 4 o 4 3 11 1 1 4 PT Thread 1 1 4 PT Thread 1 8 45 7 9 200 10 8 273 8 6 7 170 71 18 7 2 182 4 5 114 5 1...

Page 49: ...rify that power is connected to all pieces of equipment in the system Verify that the power switches are in the ON position Check the video connections Check that the BNC connectors are inserted prope...

Page 50: ...OUTDOOR HOUSING 21 99 558 3 31 84 2 m10Xp1 5 BOLT 59 15 4 M10Xp1 5 NUT 8 67 220 11 03 280 1 18 30 1 58 40 14 38 365 11 03 280 14 18 360 21 99 558 4 73 120 39 4 1000 4 89 124 4 o 43 4 89 124 1 1 4 NPT...

Page 51: ...R F POLE MOUNTADAPTOR 114 3 160 0 7 88 200 3 94 100 6 3 160 4 5 114 3 4 M8X1 25 NUT 4 33 110 o 433 11 8 27 210 6 51 165 1 6 3 160 12 61 320 12 61 320 8 27 210 4 5 114 3 6 51 165 1 o1 58 40 4 M8X1 25NU...

Page 52: ...27104AF 52 APPENDIX B OPTIONAL ITEMS G FLUSH MOUNTADAPTOR H WALL MOUNTADAPTOR 7 8 200 4 73 120 3 15 80 8 67 220 11 74 298 4 5 8 8 203 1 58 40 4 5 114 3 3 15 80 6 51 165 1 6 152 4 8 20 37 9 5 8 203...

Page 53: ...27104AF 53...

Page 54: ...27104AF 54...

Page 55: ...27104AF 55...

Page 56: ...ice Revisions or new editions to this publication may be issued to incorporate such changes PRODUCT SERVICE OpenEye website http www openeye net Call 1 888 542 1103 for questions or comments regarding...

Reviews: