background image

ChannelPlus model

H636

5 Port Ethernet Switch 10/100 BASE-T

1

2

3

4

5

TM

Power

12-15VDC 300mA

ON - 100Mbps

OFF - 10MBps

ON - Connected

BLINK - Activity

Use crossover cable for link

ChannelPlus model

H636

5 Port Ethernet Switch 10/100 BASE-T

1

2

3

4

5

TM

Power

12-15VDC 300mA

ON - 100Mbps

OFF - 10MBps

ON - Connected

BLINK - Activity

Use crossover cable for link

ChannelPlus model

H636

5 Port Ethernet Switch 10/100 BASE-T

1

2

3

4

5

TM

Power

12-15VDC 300mA

ON - 100Mbps

OFF - 10MBps

ON - Connected

BLINK - Activity

Use crossover cable for link

The H636 10/100Base-T ethernet switch

creates a home network

for two to five computers. “Plug and play” installation is easy when using the
H628 data hub. The H636 is fully IEEE802.3 compliant and has activity LEDs

for network status and speed.
T h e H 6 3 6 r e q u i r e s n o
programming and starts working
at power up with no user
intervention.

ChannelPlus

Fast Ethernet Switch

1

2

3

1) Hook from the top

2) Swing into place

3) Push button to lock

OpenHouse modules attach from the top

tm

ChannelPlus model H616

Telephone Master Hub (4 lines x 6 phones)

Telephone Master Hub (4 lines x 6 phones)

Telephones

From

Telco

From

Telco

RJ31X

Out

Expansion

Ports

Expansion

Ports

R

T

R

T

4

R

T

R

T

3

R

T

R

T

2

R

T

R

T

1

Typical Installation

Expanding the Network

Wiring the H636 Hub

- Use only Category 5 unshielded twisted-pair cable.

- When connecting to an H628 or a network device directly, use

straight through RJ-45 cables.

- Each run to a network device should be less than 100 meters (328

feet).

DECLARATION OF CONFORMITY

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE

FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2)

THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY

CAUSE UNDESIRED OPERATION.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15

of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a

residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not

installed and used according to the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does

cause harmful interference to radio or television reception, which if found by turning the equipment off and on, the

user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna

-Increase the separation between the equipment and receiver.

-Connect the equipment to an outlet other than the receiver’s outlet.

-Consult a dealer or an experienced radio/TV technician for assistance.

Power supply

LED Indicators

Network Interface

model number

105-125 VAC

Link/Activity, Speed

Use crossover cable

300mA maximum

15 VDC unregulated

Power

5

350-099

input power

each port

RJ-45 uplink

output voltage

each unit

RJ-45 ports

output current

Environmental

Compliance

operating temperature

IEEE 802.3

0°C to 50°C

100Base-T

Max cable length

CAT-5 (UTP)

100 meters (328 feet)

Specifications: typical @ 25 C ± 5 C

O

O

H636

Ethernet Hub

BASE-T (5 RJ-45 inputs, 1 uplink)

10

+5VDC

ChannelPlus model H628

Data Hub (8 cables, TIA-568A) Category 5 Compliant

H628

Straight-through cable

(H691 or H692)

H636

Ethernet hub

H636

Ethernet hub

Ethernet connections for 4 rooms

}

To data jacks

in remote

wall plates

Uplink

5

4

3

2

1

+5VDC

Using more than one hub

Crossover cable

- Use only Category 5 unshielded twisted-pair cable.

- The cable length between two hubs cannot exceed 100 meters

(328 feet).

- Additional hubs may be used as long as the path between any

two network devices does not exceed four hubs and five cables.

- All hubs used must be powered.

-A crossover cable exchanges the In and Out connections on one

end. This will convert any standard port into a “link” port.

Connecting two H636s or connecting an H636 to most firewalls

will require using a crossover cable.

ChannelPlus model

H636

5 Port Ethernet Switch 10/100 BASE-T

1

2

3

4

5

TM

Power

12-15VDC 300mA

ON - 100Mbps

OFF - 10MBps

ON - Connected

BLINK - Activity

Use crossover cable for link

ON - 100Mbps

OFF - 10Mbps

ON - Connected …

A working device is connected to this port.

BLINK - Activity …

Data is being transmitted or received by this port.

To Internet

Crossover cable

(typical)

Internet gateway

or firewall

H636

Ethernet hub

Crossover cable

LED Indicators

Ethernet switches

The H636

The H636

are superior to ordinary Ethernet hubs in that they

segment the data traffic. Computer A can talk to computer B while computers
C and D also talk. Collisions are eliminated. Throughput is greatly enhanced.

learns the addressing of your network with no programming.

will automatically detect 10 base-T or 100 base-T adaptors on a

port by port basis. The H636 will use the highest possible speed.

Reviews: