7

Technical Specifications

 

Connection Details

Figure 8

 provides an example of a transformer configuration, with a second using the same 

connections.

 

G= 2

Primary

Secondary

1

2

1

4

2

3

G= 2

Primary

Secondary

3

4

1

4

2

3

5

6

7

8

Amplifier Case

Amplifier Output Terminals

160 Vrms/50VA
Output 

5

6

7

8

Figure 8: 

Transformer connection, serial configuration

G= 2

Primary

Secondary

1

2

1

4

2

3

5

6

7

8

G= 2

Primary

Secondary

3

4

1

4

2

3

5

6

7

8

Amplifier Case

Amplifier Output Terminals

80 Vrms/50VA
Output 

Figure 9: 

Transformer connection, parallel configuration

Summary of Contents for OP8111

Page 1: ...www opal rt com OP8111 HIGH VOLTAGE AMPLIFIER USER GUIDE...

Page 2: ...Published by OPAL RT Technologies Inc 1751 Richardson suite 2525 Montreal Quebec Canada H3K 1G6 www opal rt com 2015 OPAL RT Technologies Inc All rights reserved Printed in Canada...

Page 3: ...OP8111 User Manual OPAL RT Technologies 3 CONTENTS INTRODUCTION 4 applications 4 STARTUP PROCEDURE 4 POWERING UP 4 TECHNICAL SPECIFICATIONS 5 CONNECTION DETAILS 5 SPECIFICATIONS 8...

Page 4: ...ps to properly power up the OP8111 Power Amplifier 1 Press the switch at the rear of the unit to put it in the ON position 2 Press the switch at the front of the unit to put it in the ON position Both...

Page 5: ...P8111 Power Amplifier Phase A Principle Overview Figure 6 OP8111 high voltage amplifier synoptic parallel configuration The following table provides ratings and bandwidth for inputs and output signals...

Page 6: ...1 PHASE B PHASE A UPOn UPDefault DOWNOn DOWNDefault UPOn UPDefault DOWNOn DOWNDefault UPOn UPDefault DOWNOn DOWNDefault PowerGood AC ON Figure 7 OP8111 front PHASE IN IN A 1 9 B 1 9 C 1 9 Table 9 Inp...

Page 7: ...mary Secondary 1 2 1 4 2 3 G 2 Primary Secondary 3 4 1 4 2 3 5 6 7 8 Amplifier Case Amplifier Output Terminals 160 Vrms 50VA Output 5 6 7 8 Figure 8 Transformer connection serial configuration G 2 Pri...

Page 8: ...erminal block Coupling DC referenced to its HVGND Voltage range Serial 160Vrms 50VA Parallel 80Vrms 50VA Output regulation 7 Protections Thermal and short circuit to ground Max Current Serial Config 0...

Page 9: ...OP8111 User Manual OPAL RT Technologies 9...

Page 10: ...10 OPAL RT Technologies OP8111 User Manual...

Page 11: ...every effort has been made to ensure accuracy in this publication no responsibility can be accepted for errors or omissions Data may change as well as legislation and you are strongly advised to obta...

Reviews: