background image

OP5600 SERIES V3 

Real-Time Digital Simulator  

OP5650 User Manual 

Artix 7

www.opal-rt.com

Summary of Contents for OP5600 V3 Series

Page 1: ...OP5600 SERIES V3 Real Time Digital Simulator OP5650 User Manual Artix 7 www opal rt com...

Page 2: ...Published by OPAL RT Technologies Inc 1751 Richardson suite 2525 Montreal Quebec Canada H3K 1G6 www opal rt com 2018 OPAL RT Technologies Inc All rights reserved Printed in Canada...

Page 3: ...on within the bookset CAUTION Indicates a situation which if not avoided may result in equipment or work data on the system being damaged or lost or may result in the inability to properly operate the...

Page 4: ......

Page 5: ...AND CONFIGURATION 10 HARDWARE CONFIGURATION 11 back connectors 13 Connecting the Ground Screw 14 DB37F CONNECTIONS 15 OP5650 DB37 PIN ASSIGNMENTS 17 RJ45 CONNECTIONS 18 RJ45 CHANNEL ASSIGNMENTS 19 con...

Page 6: ...OP5600 OP5650 User Manual OPAL RT Technologies 6...

Page 7: ...37 TestBoard Loopback Flat cable Power cable For Quick testing and Troubleshooting 126 0361 113 0737 113 0799 Power cable 1 83 m 6 power cord black 10A 125V Power Cord 6ft European Schuko CEE7 7 to C1...

Page 8: ...andard configuration the lower part of the chassis contains a powerful target computer that can be added to a network of simulators or can act as a standalone The target computer used to run simulatio...

Page 9: ...es 4U Xeon E5 8 Cores 3 2 GHz 20M 16GB 512GB SSD OP5650 16 OP5650 RCP HIL Artix 7 FPGA based Real Time Simulator 16 cores 4U Xeon E5 2x8 Cores 3 2 GHz 2x20M 2x16GB 512GB SSD OP5650 32 OP5650 RCP HIL A...

Page 10: ...P5650 to the same network used by the host PC using the cables provided Figure 2 Top view of mezzanines installed on carrier The top of the chassis can be removed to access the signal conditioning mez...

Page 11: ...es on the carrier board Analog mezzanines channels 0 16 will use only the first column of connectors Digital mezzanines will use both columns channels 0 15 in the first column and channels 16 31 on th...

Page 12: ...ing Green NIC1 On indicates that network port 1 is in use Green NIC2 On indicates that network port 2 is in use Red Power Fail On indicates a power fault Red Overheat Fan Fail On indicates either that...

Page 13: ...and 5 12V power source connector for test purposes Pushbutton reset after 4A overcurrent shutdown Red LED indicates fault green LED indicates nominal function Microfit connector for 5V or 12V power a...

Page 14: ...ent electric shocks protect the OP5650 from voltage spikes from a variety of causes including lightening strikes and provide increased immunity from EMI by lowering noise levels and emissions 1 Select...

Page 15: ...els from Group A which are linked to the conditioned channels from the front mezzanine DB37 connector panel GROUP 1A GROUP 1B GROUP 1A GROUP 1B OP5600 Front RJ45 OP5600 Rear DB37 GROUP 1B GROUP 1A ANA...

Page 16: ...6 to 31 are on the second connector If the back mezzanine is a digital module Din or Dout the first 16 channels 00 to 15 are on the first connector and the next 16 channels 16 to 31 are on the second...

Page 17: ...H27 13 CH12 32 CH12 13 CH28 32 CH28 14 CH13 33 CH13 14 CH29 33 CH29 15 CH14 34 CH14 15 CH30 34 CH30 16 CH15 35 CH15 16 CH31 35 CH31 17 36 17 36 18 Vuser 1 A 37 Vrtn 1 A 18 Vuser 2 A 37 Vrtn 2 A 19 19...

Page 18: ...ects to front and back mezzanines The following images illustrate how the mezzanines are linked to the connectors GROUP1A GROUP1B GROUP1A GROUP1B channels 0 15 ANALOG NOT USED Digital Channels 16 31 c...

Page 19: ...h column represents a series of channels divided into 4 channels per jack as shown in Figure 11 SLOT xA SLOT xB Column 1 Channels 0 3 Channels 4 7 Channels 8 11 Channels 12 15 Column 2 Channels 16 19...

Page 20: ...y be connected to the standard computer connector network jack see page 15 DO NOT connect the network cable in any jack other than the jack intended for that purpose A B C Figure 10 How to connect cab...

Page 21: ...rpm SATA Dimensions 48 3 x 45 7 x 17 8cm 19 x 18 x 7 Weight With PC 9 07 15 Kg 20 lbs to 33 lbs Without PC 4 54 5 9 Kg 10 lbs to 13 lbs Operating temperature 10 to 35 C 50 to 95 F Storage temperature...

Page 22: ...OP5650 User Manual OPAL RT Technologies 22 Limited Warranty...

Page 23: ...rma request click on support and select Return Merchandise RMA 2 Fill out the online form and submit You will receive a notification with a thread ID that will be used for further exchange with suppo...

Page 24: ...able to this purchase All other warranties express or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose are hereby disclaimed Limitatio...

Page 25: ......

Page 26: ...every effort has been made to ensure accuracy in this publication no responsibility can be accepted for errors or omissions Data may change as well as legislation and you are strongly advised to obta...

Reviews: