OP4200 RCP/HIL SYSTEM
USER MANUAL
www.opal-rt.com
Page 1: ...OP4200 RCP HIL SYSTEM USER MANUAL www opal rt com...
Page 2: ...Published by OPAL RT Technologies Inc 1751 Richardson suite 2525 Montr al Qu bec Canada H3K 1G6 www opal rt com 2018 OPAL RT Technologies Inc All rights reserved Printed in Canada...
Page 3: ...ithin the bookset CAUTION Indicates a situation which if not avoided may result in equipment or work data on the system being damaged or lost or may result in the inability to properly operate the pro...
Page 4: ......
Page 5: ...BLING INSTRUCTIONS 13 Connect the Power Cable 13 Connecting the Ground Screw 14 Connecting Network Cable 14 INITIAL SETUP 15 DIP Switch Configurations 15 Changing the IP Address 16 Testing Signals Usi...
Page 6: ...SPECIFICATIONS 30 OP4200 GENERAL SPECIFICATIONS 30 OP4230 1 SPECIFICATIONS 31 OP4240 1 SPECIFICATIONS 32 OP4242 1 SPECIFICATIONS 33 OP4250 1 SPECIFICATIONS 34 OP4260 1 SPECIFICATIONS 35 LIMITED WARRAN...
Page 7: ...options 2 CAN 2 RS232 1 Ethernet I O CONFIGURATIONS The OP4200 simulator provides signal conditioning for up to 128 I Os which are managed from the PL FPGA section of the Zynq module The I O lines are...
Page 8: ...The communication speed is configurable between 1 and 5 GBps and the SFP transceivers should be selected accordingly OPAL RT MUlti System Expansion link MUSE 1 this mode encapsulates the Aurora proto...
Page 9: ...uter T00 0814 T00 0994 1 1 Power Supply Desktop AC Adapter 60W 24V pluggable terminal blocks 4 pos T00 4387 T00 0509 1 1 OP5972 Power jack adapter kit for OP4200 power input 0310 0287 Auxiliary power...
Page 10: ...ction MUSE link requires specific SFP and cable SFP Avago AFBR 57R5APZ Cable LC LC multimode 850nm optical fiber C RJ45 network connection and USB 2 0 connector D Fiber optic connectors Rx and Tx used...
Page 11: ...ay a condition specified by the user If undefined displays no status SYNC TX Green Lights to indicate when unit transmits a synchronization signal SYNC RX Green Lights to indicate when unit receives a...
Page 12: ...ng details Digital cassettes have two DB37 connectors one for channels 00 15 and one for channels 16 31 and analog cassettes have one DB37 connector for channels 00 15 Cassette LEDs Each cassette has...
Page 13: ...e OP4200 to the nearest ground to prevent any EMI related damage to the simulator GENERAL CABLING INSTRUCTIONS The OP4200 provides a number of connectors that each allow users a specific interaction w...
Page 14: ...es best protection with ring terminals on each end Attach one ring terminal to the ground screw on the OP4200 shown in Figure 4 Attach the other ring terminal to the nearest ground source using a nut...
Page 15: ...and operation parameters After a Reset the boot mode switches are read to determine the primary boot device used default mode is boot from SD card 1 2 3 4 5 6 7 8 Figure 6 DIP Switch SW Description F...
Page 16: ...e It also allows users to perform various troubleshooting or reflashing activities OP4200 TO PC USB RS232 TO OP4200 Figure 7 Connecting the RS232 to USB cable 4 Connect the USB connector to a computer...
Page 17: ...ld select Microcom to have the rest of the parameters selected automatically g Click OK to start the session If the OP4200 was already switched on before starting this process clicking OK does not ope...
Page 18: ...following information in the next screen Figure 11 IP address Netmask and Gateway your IT department should provide you with the information Figure 11 IP address modification screen Click Submit A con...
Page 19: ...onnecting the output cassette to the input cassette If the input reads each output signal the unit is functioning properly and is ready to be put into service OUTPUT CASSETTE LOOPBACK BOARD INPUT CASS...
Page 20: ...05 04 03 11 10 09 08 07 14 13 12 15 19 37 Vuser Vrtn 2 CH01 21 CH01 2 CH17 21 CH17 3 CH02 22 CH02 3 CH18 22 CH18 4 CH03 23 CH03 4 CH19 23 CH19 5 CH04 24 CH04 5 CH20 24 CH20 6 CH05 25 CH05 6 CH21 25 CH...
Page 21: ...ARDWARE SETUP Problem Possible Cause Solution Nothing happens when I connect my RS232 cable RS232 cable driver not detected Download driver from http www prolific com tw US ShowProduct aspx p_id 225 p...
Page 22: ...22 OPAL RT Technologies OP4200 User Manual...
Page 23: ...ll channels are simultaneously sampled The onboard EEPROM provides offset and gain data adjustment written during the calibration process as well as over voltage protection By default the maximum outp...
Page 24: ...DWARE CASSETTES TYPICAL APPLICATIONS The following diagrams provide an example of a typical application using the OP4230 1 Signal Conditionning VDC GND 15mA max Analog In OP4230 1 Analog Output Client...
Page 25: ...tal converter By default the maximum input signal is set to 20 volts SCHEMATICS Figure 3 represents a simplified schematic of one channel of the OP4240 1 modules It is composed of three stages the fir...
Page 26: ...put channels Each channel uses a 16 bit resolution analog to digital converter By default the maximum input signal is set to 20 volts SCHEMATICS The figure below represents a simplified schematic of t...
Page 27: ...on Hardware configurable filters and conditioning inputs for customization Choice of sink or source inputs connection anode and cathode side available Minimum current input of 3 6 mA 5V to 30V input v...
Page 28: ...signal is high The signal conditioning module inputs have both anode and cathode sides available to the user on the I O connector MODE 1 COMMON ANODE R VUser Din I Max 10 mA Figure 19 Both Din and Di...
Page 29: ...25 C at 5 V Low ON OFF time propagation delay 65ns 25 C from 15 to 30 V optional Outputs are tri stated Outputs may be connected in parallel for higher 2 times current capability use matched pair exam...
Page 30: ...7 FPGA 125K LUT I O lines 128 lines routed to cassette conditioning modules Communication ports 2 GTX SFP connectors up to 5Gbps I O connectors DB37F RS232 CAN I O cassette slots 4 slots for I O casse...
Page 31: ...t s Serial Output Transfer Dc Transfer Characteristics CMRR 100 dB Dynamic Characteristics Calibration Programmable gain and offset calibration for each D A Calibration factors are stored in on board...
Page 32: ...Ranges V Positive Full Scale Negative Full Scale 120 0 120 0 100 0 100 0 80 0 80 0 60 0 60 0 40 0 40 0 20 0 hardware default value 20 0 Calibration Calibration factors are stored in on board non volat...
Page 33: ...M Max Sampling Frequency 2 MSPS Min Conversion Acquisition Time 510 nanoseconds per channel on OP4200 ADC Type 8 x Dual ADC Input voltage range 20V Bandwidth Small signal 3 dB 400 kHz Accuracy 10mV o...
Page 34: ...voltage protection Schottky diode Maximum reverse voltage protection 30 Volts Detection threshold Separate Schmitt Trigger Voltage range 4 to 50 Vdc Delay Low to High 110 ns Delay High to Low 60 ns R...
Page 35: ...tage 30V 5 Under voltage protection 5V 2 5 Reverse voltage maximum 30 V Output Voltage range 5 to 30 Vdc max Output configuration Push pull tri state output Delay Low to High 65ns 25 C for 30 V 200ns...
Page 36: ...ebsite www opal rt com support return merchandise authorization rma request click on support and select Return Merchandise RMA 2 Fill out the online form and submit 3 OPAL RT s Support department will...
Page 37: ...able to this purchase All other warranties express or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose are hereby disclaimed LIMITATIO...
Page 38: ...every effort has been made to ensure accuracy in this publication no responsibility can be accepted for errors or omissions Data may change as well as legislation and you are strongly advised to obta...