Air Quality Monitoring 

 

Warning

 - Deployment of a monitor/detector is essential for the safe operation of any equipment 

that has the potential to produce CO. CO sensors/detectors became available on the mass market 
around 1978. The main differences between the technologies involved are battery or electric and 
Semiconductor or Biomimetic types. Detectors for carbon monoxide (CO) are manufactured and 
marketed for use in either the home or occupational industrial settings. The detectors for home 
use are devices that will sound an alarm before CO concentrations in the home become 
hazardous. There is an Underwriters Laboratories, Inc., performance standard (UL 2034) for 
residential CO detectors. Detectors currently available on the market are battery-powered, plug-in, 
or hardwired. Some models incorporate a visual display of the parts per million (ppm) 
concentration of CO present in the home. For more information on CO detectors for home use, call 
the Consumer Product Safety Commission: 

 

Commission Hotline at 1-800-638-2772 

 

CO detectors for use in residential settings are not designed for use in workplace settings.  
Monitoring requirements in an occupational setting are different from monitoring requirements in 
the home. In the workplace, it is frequently necessary to monitor a worker's exposure to carbon 
monoxide over an entire work shift and determine the time-weighted average (TWA) concentration 
of the exposure. It may also be necessary to have carbon monoxide monitors with alarm 
capabilities in the workplace. The direct reading instruments are frequently equipped with audio 
and/or visual alarms and may be used for area and/or personal exposure monitoring. Some have 
microprocessors and memory for storing CO concentration readings taken during the day. It is 
significant to note that some of the devices mentioned for workplace CO monitoring are not 
capable of monitoring TWAs, and not all are equipped with alarms. The appropriate monitor must 
be chosen on an application-by-application basis. For more information on the availability of 
workplace CO monitors or their application, call the National Institute for Occupational Safety and 
Health at 1-800-35-NIOSH (1-800-356-4674). 

 

Room Size and Time Estimations for Parts Per Million (PPM) CO 
The fundamental factors in area CO levels involve: 
The concentration and volume of CO production; 
The size of the area; 
The amount of air exchange if any; 
The amount of time CO is produced; 
Multiplying length, width, and height will determine the volume or cubic feet in a room. So an 
empty building 100ft by 100ft with a 10ft ceiling would be 100,000 cubic ft. in size. Any material 
that is in the room and takes space would reduce the cubic feet. 

 
 

* Air exchange is defined as the exhausting of internal air to the external atmosphere. 

The Graph above depicts the relationships of air exchange to time and CO ppm with 
cubic feet area and percent CO emissions remaining constant. 

 
 
 
 
 
 
 
 
 
 
 

 

9

 

Summary of Contents for S1PAMN

Page 1: ...S4XBMN 21 17HP S1PAMN S1PBMN 24 17HP S4PAMN S4PBMN 27 17HP S7PAMN S7PBMN 27 18HP TRU VAC S7ZBMNTV 27 18HP PASSIVE VAC S7ZBMNDC FLOOR STRIPPERS 21 18HP STIP BUFF S1ZAMJ 24 18HP TRI STRIP S4ZBMNTE 27 1...

Page 2: ...l manejo 0 servicio de esta maquina All directions given in this book are as seen from the operator s position at the rear of the machine For new books write to INFO ONYXSOLUTIONS COM DANGER It is the...

Page 3: ...ustments 17 Warranty Information 21 SECTION II Schematics Detailed Description of Machines 23 This Owner s Manual Safety Procedures Guide has been prepared for the promotion of educational purposes on...

Page 4: ...in SERIOUS INJURY OR DEATH to the operator and those in the contaminated area The effects of CO can be experienced at different exposure levels depending on the health of the individual Conditions th...

Page 5: ...Burnishing versus Stripping When activity is concentrated to a smaller area as in a stripping application air stirring must be forced by use of fans to reduce the risk of high concentrations of CO Ai...

Page 6: ...he toxic effects of carbon monoxide in the blood are the result of tissue hypoxia lack of oxygen carbon monoxide combines with hemoglobin to form carboxyhemoglobin Since CO and oxygen react with the s...

Page 7: ...ons of CO Air exchange rates air exchange is defined as the exhausting of internal air to the external atmosphere the size of the Effective Operating Zone amount of CO produced level of human activity...

Page 8: ...ll concentrated on one side of the Dividing zone Note the Dividing Zone shown above this is the line where airflow changes direction In Model 3 air changes are cut in 1 2 as little or no CO crosses th...

Page 9: ...ime weighted average TWA concentration of the exposure It may also be necessary to have carbon monoxide monitors with alarm capabilities in the workplace The direct reading instruments are frequently...

Page 10: ...e during 8 hour time period The Graph above depicts the relationships of air exchange to time and CO ppm with cubic feet area and percent CO emissions remaining constant Based on the CO production rat...

Page 11: ...when the air to fuel ratio becomes fuel rich Follow the recommended Maintenance Schedule for the engine found in the Engine Operator Owner Manual as well as the Maintenance And Adjustments schedule fo...

Page 12: ...d Standard Emission Shutdown Standard Standard Clutch None None Pad Speed 2100 RPM 1500 RPM Propane Tank 20 lb 9 1 kg Capacity 80 Safety Fill Low Oil Shutdown Standard Standard Hour Meter Standard Sta...

Page 13: ...s machine can cause serious injury and or damage Do not allow contact of clothing hair hands feet or other body parts with the rotating pad Keep other people away from the machine while it s in operat...

Page 14: ...f vibration If the symptoms still persist discontinue operation of the machine Introduction to the Floor Care Machine ONYX propane floor care equipment is manufactured in two basic concepts the buffer...

Page 15: ...endors should be familiar with this operation and will provide this service Recommended Purge Procedures How to purge new LP Gas Buffer cylinders equipped with the Overfill Prevention Device New conta...

Page 16: ...chine For Use BEFORE using any type of powered equipment proper safety dictates you should visually inspect it 1 Adjust the HANDLE to a comfortable height and tighten the bolts 2 BONNET FILTER Make su...

Page 17: ...d type crankcase emission control system is used to eliminate blow by gases The blow by gases are led to the breather chamber through the crankcase Then it is led to the air cleaner Oil is separated f...

Page 18: ...xhaust side down KAWASAKI twin cylinder Do not tilt the machine on its nose as this is where the carburetor is located It is okay to turn this model on either its left or right side a Remove pad b Use...

Page 19: ...ft 3 ENGINE STARTS AND IDLES BUT WILL QUIT AS THE THROTTLE IS ADVANCED It is possible that the propane tank s service valve is faulty To check for this close the valve completely and then reopen very...

Page 20: ...came with the battery charger REMINDER this will continue to happen unless the buffer s engine is run for sufficient time between starts to recharge the battery 7 KAWASAKI V TWIN ENGINE BEGINS TO BAC...

Page 21: ...he engine but not enough for full throttle operation As the throttle is increased allowing more air to enter the intake the engine will quit from fuel starvation Call your dealer or the factory for in...

Page 22: ...ion of ONYX under this Warranty is limited to repairing or replacing at its option any part which is proven to be defective in material or workmanship under normal use for the applicable period stated...

Page 23: ...23 SCHEMATICS DETAILED DESCRIPTION OF MACHINES...

Page 24: ...1 3 4 5 6 8 7 9 10 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 11 40 41 42 2 PANTHER SCHEMATIC PART S32ZBMNE 43 44...

Page 25: ...6 FS2150 LH TANK RECEIVER 17 FS2160 RH TANK RECEIVER 18 W3132 ENGINE KAWASAKI FS481V 19 FS3300 MUFFLER 20 FS3200 EXHAUST MANIFOLD 21 FS2200 GEARBOX COVER 23 FS2300 V BELT B56 24 FS1700 REAR GEARBOX MO...

Reviews: