background image

H e a l t h c a r e   I n f o t a i n m e n t

O N Y X - B E 1 8 1

 

 

Chapter 1 General Information 

1-1

 

 

 
 

General 

Information 

 
 

 
 
 
 
 

Chapter 

1

Summary of Contents for BE181

Page 1: ...are Infotainment O N Y X B E 1 8 1 ONYX BE181 18 5 Bedside Terminal Intel Atom Dual Core D525 Processor High Performance Low Power Consumption Wide LCD with Multimedia ONYX BE181 Manual 1st Edition De...

Page 2: ...is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its us...

Page 3: ...gistered trademark of Microsoft Corporation RTL is a trademark of Realtek Semi Conductor Co Ltd C T is a trademark of Chips and Technologies Inc UMC is a trademark of United Microelectronics Corporati...

Page 4: ...the ONYX BE181 CD ROM into external CD ROM drive which contains User s Manual in PDF format Drivers and Utilities If any of these items are missing or damaged you should contact your distributor or s...

Page 5: ...714 792 0481 Email usasales onyx healthcare com Onyx Healthcare EUROPE B V Ekkersrijt 4002 5692 DA Son The Netherlands Tel 31 0 499 462020 Fax 31 0 499 462010 Email eusales onyx healthcare com Onyx H...

Page 6: ...m 1318 Metallurgy Building East Zhongshan Road Nanjing China Tel 86 025 58859841 Fax 86 025 85088070 Email Jonwang onyx healthcare com Onyx Healthcare Singapore PTE LTD 57 Genting Lane 07 00 Singapore...

Page 7: ...could cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before...

Page 8: ...DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F IT MAY DAMAGE THE EQUIPMENT 16 External equipment intended for connection...

Page 9: ...Healthcare Infotainment O N Y X B E 1 8 1 Caution It may cause the danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer...

Page 10: ...st electric shock not classified 2 Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide 3 Mode of operation Continuous 4 Type of pr...

Page 11: ...vice complies with Part 18 FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received inclu...

Page 12: ...Healthcare Infotainment O N Y X B E 1 8 1 UL Module Description BE181 AC modules are developed to suitable for the Classification Mark requirement...

Page 13: ...ock fire and mechanical hazards only in accordance with UL 60601 1 and CAN CSA C22 2 NO 601 1 Attention consult ACCOMPANYING DOCUMENTS Ground wire Protective Ground wire Medical equipment with respect...

Page 14: ...ns 2 2 2 2 A Quick Tour of the BE181 2 3 2 3 Mounting Installing 2 5 Chapter 3 American Megatrends BIOS Setup 3 1 System Test and Initialization 3 2 3 2 American Megatrends BIOS Setup 3 3 3 3 Main Fea...

Page 15: ...otainment O N Y X B E 1 8 1 A 1 I O Address Map A 2 A 2 Memory Address Map A 3 A 3 IRQ Mapping Chart A 4 Appendix B Miscellanea B 1 General Cleaning Tips B 2 B 2 Cleaning Tools B 3 B 3 Scrap Computer...

Page 16: ...Healthcare Infotainment O N Y X B E 1 8 1 Chapter 1 General Information 1 1 General Information Chapter 1...

Page 17: ...th renowned software solution partners ONYX BE181 bedside terminals provide patients with capabilities like Entertainment on Demand Online Access VoIP Phone Nurse Notification etc Clinical Application...

Page 18: ...lay Intel Atom Dual Core D525 1 8GHz Processor Fanless Compact Design VoIP phone Web Camera and High Quality Speaker Smart Card Reader Optional Features Magnetic Stripe reader RFID 2nd Smart Card Read...

Page 19: ...5 1 8GHz on board Processor LCD Controller Intel Atom Dual Core D525 Shared memory up to 224MB System Memory Up to 4GB DDRIII 1066 1333 Display BE181 18 5 Wide Color TFT LCD with WLED Backlight OS Sup...

Page 20: ...xel 2 x Alarm Light optional 1 x Nurse Notification Connector optional 1 x Buzzer GPIO Controllable On Off Volume Accessory Optional 1 x MSR RS 232 Interface 1 x Bottom Barcode Reader TTL Interface 1...

Page 21: ...2 x Gigabit Ethernet Support WOL Membrane Function Audio control Volume Volume LCD on off Brightness control Brightness Brightness Programmable function key I O Cont Video 1 x Video in Optional via M...

Page 22: ...ot able to change color This is a normal occurrence for all LCD displays from all manufacturers and should not be noticeable or objectionable under normal operation ONYX LCD panels are qualified for i...

Page 23: ...rol design Anti microbial design Optional Telephone Left side of Bedside Terminal Front I O 2USB Mic Headset Cover with plastic cover to avoid patient direct access Web Camera Top Center Position on t...

Page 24: ...ated Hours 7 years Environmental Specification Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 60 C 4 F 140 F Pressure 850 1000hPa Operating 850 1000hPa Transport Storage Storage Hu...

Page 25: ...Healthcare Infotainment O N Y X B E 1 8 1 Chapter 1 General Information 1 10 1 4 Dimension Bedside Terminal BE181...

Page 26: ...Healthcare Infotainment O N Y X B E 1 8 1 Chapter 1 General Information 1 11...

Page 27: ...Healthcare Infotainment O N Y X B E 1 8 1 Chapter 2 Hardware Installation 2 1 Hardware Installation Chapter 2...

Page 28: ...he power is on because a sudden rush of power can damage sensitive electronic components Always ground yourself to remove any static charge before touching the board Modern electronic devices are very...

Page 29: ...NYX BE181 please take a moment to familiarize yourself with the locations and purposes of the controls drives connections and ports The following figures illustrate the fully loaded bedside terminal w...

Page 30: ...de Terminal the back I O section Digital IO USB LAN and Power connector is just below the VESA mounting area Picture 224 Bedside Terminal Rear View Isolated Gigabit LAN GPIO DC in Phone Line Barcode S...

Page 31: ...eader MSR option upon request Please refer to the following figure for installation location on the ONYX BE181 Bedside Terminal 2 3 Mounting Installing Onyx BE181 is suitable for VESA75 100mm interfac...

Page 32: ...Healthcare Infotainment O N Y X B E 1 8 1 Chapter 3 Award BIOS Setup 3 1 American Megatrends BIOS Setup Chapter 3...

Page 33: ...F1 key to continue the boot up sequence System configuration verification These routines check the current system configuration against the values stored in the CMOS memory If they do not match the p...

Page 34: ...and press Del immediately This will allow you to enter Setup Main Features Use this menu for checking BIOS and build version Basic system configuration can be done under this tab Date and Time Advanc...

Page 35: ...4 Advanced Features Choosing the Advanced Features option from the INITIAL SETUP SCREEN menu and you will see this screen contains the manufacturer s default values for the ONYX BE181 3 5 Chipset Fea...

Page 36: ...stem Enter a password each time the system boots and whenever you enter Setup Setup Enter a password whenever you enter Setup NOTE To clear the password simply press Enter when asked to enter a passwo...

Page 37: ...Healthcare Infotainment O N Y X B E 1 8 1 Chapter 4 Driver Installation 4 1 Driver Installation Chapter 4...

Page 38: ...Driver Step 4 Install AUDIO Driver Step 5 Install Touch Screen Driver Step 6 Install Smart Card Driver Optional Features Step 7 Install MSR Driver Step 8 Install TV Tuner Driver Step 9 Install Barcode...

Page 39: ...ill help you install the driver automatically Step 2 Install VGA Driver 1 Click on the Step 2 VGA driver folder and select the corresponding folder for your operating system and double click on Setup...

Page 40: ...Click on the PenMount Windows Universal Driver V2 2 0 283 Win7_32_64bit_WHQL folder and double click on Setup exe file 2 Follow the instructions that the window shows 3 The system will help you instal...

Page 41: ...ally Step 8 Install TV Tuner Driver 1 Click on the Step 8 TV Tuner driver folder and select the corresponding folder for your Local TV signal a Click on H339_Install_DVBT folder and select setup exe i...

Page 42: ...and double click on setup exe for x86 32bit OS if the OS is Windows 64bit OS please select the Winx64 folder and double click on setup exe file 3 Follow the instructions that the window shows 4 The s...

Page 43: ...Healthcare Infotainment O N Y X B E 1 8 1 Appendix A I O Information A 1 I O Information Appendix A...

Page 44: ...Healthcare Infotainment O N Y X B E 1 8 1 Appendix A I O Information A 2 A 1 I O Address Map...

Page 45: ...Healthcare Infotainment O N Y X B E 1 8 1 Appendix A I O Information A 3 A 2 Memory Address Map...

Page 46: ...Healthcare Infotainment O N Y X B E 1 8 1 Appendix A I O Information A 4 A 3 IRQ Mapping Chart...

Page 47: ...Healthcare Infotainment O N Y X B E 1 8 1 Appendix B Miscellaneous B 1 Miscellaneous Appendix B...

Page 48: ...fore you start to clean up the component or computer 4 Never drop the components inside the computer or get circuit board damp or wet 5 Be cautious of all kinds of cleaning solvents or chemicals that...

Page 49: ...leaning that component If this is the case it will be mentioned in the cleaning tips Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be...

Page 50: ...Foam swabs Whenever possible it is better to use lint free swabs such as foam swabs Please follow the steps below before cleaning the device 1 Close all application programs 2 Close operating software...

Page 51: ...we strongly recommended that we are informed as soon as possible enabling us to find a suitable solution For computers that are no longer useful please contact worldwide distributors for recycling The...

Reviews: