background image

B e d s i d e   T e rm i n al  

O N Y X - B E 1 0 0

 

 

 

Safety Symbol Description 

The following safety symbols are the further explanations for your 

reference. 

 

Medical equipment with respect to electric 
shock, fire and mechanical hazards only in 
accordance with ANSI/AAMI ES 60601-1, 
and CSA C22.2 NO 60601-1-08-CAN/CSA 

 

Attention, consult ACCOMPANYING 
DOCUMENTS. 

 

 

Ground wire 
Protective Ground wire. 

 

 

Medical equipment with respect to electric 
shock, fire and mechanical hazards only in 
accordance with ANSI/AAMI ES 60601-1, 
and CSA C22.2 NO 60601-1-08-CAN/CSA 

 

Touch Panel and Plastic Enclosure treat 
as Type B applied part. 

Summary of Contents for BE100

Page 1: ...Bedside Terminal O N Y X B E 1 0 0 BE100 10 1 Mini Bedside Terminal SAMSUNG S5PV210 800MHzProcessor Ultra Low Power Consumption Fanless compact design BE100 Manual 1st Edition October 2011...

Page 2: ...intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use Th...

Page 3: ...ed trademark of Microsoft Corporation RTL is a trademark of Realtek Semi Conductor Co Ltd C T is a trademark of Chips and Technologies Inc UMC is a trademark of United Microelectronics Corporation ITE...

Page 4: ...ONYX BE100 CD ROM into external CD ROM drive which Contains User s Manual in PDF format Drivers and Utilities If any of these items are missing or damaged you should contact your distributor or sales...

Page 5: ...4 996 1811 Email usasales onyx healthcare com Onyx Healthcare EUROPE B V Ekkersrijt 4002 5692 DA Son The Netherlands Tel 31 0 499 462020 Fax 31 0 499 462010 Email eusales onyx healthcare com Onyx Heal...

Page 6: ...18 Metallurgy Building East Zhongshan Road Nanjing China Tel 86 025 58859841 Fax 86 025 85088070 Email Jonwang onyx healthcare com Onyx Healthcare Singapore PTE LTD 57 Genting Lane 07 00 Singapore 349...

Page 7: ...d cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before con...

Page 8: ...TROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F IT MAY DAMAGE THE EQUIPMENT 16 External equipment intended for connection to signal input output or other connec...

Page 9: ...X B E 1 0 0 18 WARNING No modification of this equipment is allowed Caution It may cause the danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommend...

Page 10: ...uitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide 3 Mode of operation Continuous 4 Type of protection against electric shock Class I equipment...

Page 11: ...e complies with Part 15 FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received includin...

Page 12: ...Bedside Terminal O N Y X B E 1 0 0 UL Module Description BE100 AC modules are developed to suitable for the Classification Mark requirement...

Page 13: ...mechanical hazards only in accordance with ANSI AAMI ES 60601 1 and CSA C22 2 NO 60601 1 08 CAN CSA Attention consult ACCOMPANYING DOCUMENTS Ground wire Protective Ground wire Medical equipment with r...

Page 14: ...ure 1 3 1 3 Specification 1 4 1 4 Dimension 1 10 Chapter 2 Hardware Installation 2 1 Safety Precautions 2 2 2 2 A Quick Tour of the BE100 2 3 2 3 Mounting Installing 2 5 2 4 Powering on the unit Appen...

Page 15: ...Bedside Terminal O N Y X B E 1 0 0 Chapter 1 General Information 1 1 General Information Chapter 1...

Page 16: ...t experiences within the hospital Packaged with renowned software solution partners 10 1 BE100 bedside terminals provides patients with capabilities like Entertainment on Demand Online Access VoIP Pho...

Page 17: ...essor 10 1 16 9 wide color TFT LED LCD display 1024 x 600 Fanless Compact Design Smart Card Reader Less than 10 watt power Energy Saving Hardware Decoder Support H 264 up to 1080i MPEG4 up to 1080i MP...

Page 18: ...y 512MB DDR2 533MHz Display 10 1 Color TFT LED LCD OS Support Android 2 2 Froyo SDK for SW party developing AP UI Expansion VoIP Phone RFID Function Optional Main Specification Cont System Storage 512...

Page 19: ...mbrane Function Audio control Volume Volume LCD on off Brightness control Brightness Brightness Programmable function key I O Cont Speaker 2 x 2W High Quality Speakers LCD Specification Model BE100 Se...

Page 20: ...pixels on a screen or if there are 3 within 1 inch square area of each other on the display Touch Screen Type 4 Wire Resistive Resolution 1024 x 600 Light Transmission 78 Lifetime 10 million activiti...

Page 21: ...MPU30A 3 Input Voltage AC 100 240V 0 8A 0 4A 50 60Hz Output Voltage DC 12V 2 5A MTBF 150 000 hrs minimum at full load 25 C Environmental Specification Operating Temperature 0 C 40 C 32 F 104 F Storag...

Page 22: ...Bedside Terminal O N Y X B E 1 0 0 Chapter 1 General Information 1 8 EMC CE FCC Class B EN60601 1 3 Applied Part Infection Control Anti microbial bezel material optional...

Page 23: ...Bedside Terminal O N Y X B E 1 0 0 Chapter 1 General Information 1 9 1 4 Dimension...

Page 24: ...Bedside Terminal O N Y X B E 1 0 0 Chapter 2 Hardware Installation 2 1 Hardware Installation Chapter 2...

Page 25: ...power is on because a sudden rush of power can damage sensitive electronic components Always ground yourself to remove any static charge before touching the board Modern electronic devices are very se...

Page 26: ...Before you start to set up the BE100 please take a moment to familiarize yourself with the locations and purposes of the controls drives connections and ports The following figures illustrate the ful...

Page 27: ...Bedside Terminal O N Y X B E 1 0 0 Chapter 2 Hardware Installation 2 4 Picture 2 2 Bedside Terminal Rear View...

Page 28: ...ating the Medical PC please allow 15cm clearance area for optimal heat dissipation 2 4 Powering on the unit 1 Connect the 12 DC adaptor to the DC jack of BE100 2 Press the on off button on the front p...

Page 29: ...roid network setting 4 The unit can be connected to the RS232 port of a PC However this should be done only by Maintenance technician for debugging purpose 5 There are 2 x USB type A port that can con...

Page 30: ...X B E 1 0 0 Chapter 2 Hardware Installation 2 7 2 6 Operating the Unit 1 The devices connecting to the unit can all be hot plugged 2 Shutting down the system can be done by simply removing the power...

Page 31: ...Bedside Terminal O N Y X B E 1 0 0 Appendix A Miscellanea A 1 Miscellanea Appendix A...

Page 32: ...u start to clean up the component or computer 4 Never drop the components inside the computer or get circuit board damp or wet 5 Be cautious of all kinds of cleaning solvents or chemicals when you use...

Page 33: ...that component if this is the case it will be mentioned in the cleaning tips Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used on...

Page 34: ...enever possible it is better to use lint free swabs such as foam swabs Please follow the steps below before cleaning the device 1 Close all application programs 2 Close operating software 3 Turn off p...

Page 35: ...ongly recommended that you should inform us as soon as possible for the suitable solution For the computers that are no longer useful or work well please contact with worldwide distributors for recycl...

Reviews: