Onyx Controls ONX908MTW-0/24V Installation And Operation Instructions Download Page 5

CONFIGURATION  

The configuration menu allows you to set certain thermostat operating characteristics to your system or 

personal requirements. Switch off the thermostat and hold the sleep operation Button 

 for over 3 second till 

power on again means you have entered the first configuration menu item. There are 6 menu items. Press 

button 

 to change to the next item. To exit the menu and return to the normal operation, switch off the 

thermostat and switch it on

 aga

in. If no keys are pressed within 20 seconds the thermostat will be switched off. 

Step Press 

buttons 

Displayed

factory default

Press

▲、▼

to select

Descriptions 

 3 seconds 

01    (0) 

-3 --- +3 

Adjust temperature coefficient 

 02 

 

35

℃)

 20

—35

 

Select maximum setting temperature for heating 

 03 

 

5

℃)

 

5

—20

 

Select minimum setting temperature for cooling   

 

04      (rd) 

rd, rE 

Memorize option before power loss 

 

05 

FA

 

FA/SL 

Second stage fast or slow 

6

 

 06 

 1 

 

1

2

Display backlight option 

 

06 (On) 

On/Off 

Fan option is heating mode. 

 

07    (3) 

0,3,5 

Minimum compressor off-time setting 

1)  Select temperature recalibrates Adjustment 3 LO to 3 HI 

You can adjust the room temperature display up to 3 higher or lower. Your thermostat was accurately calibrated 

at the factory but you have the option to change the display temperature to match your previous thermostat. 

2)  Select maximum temperature for heating. 

 

This feature provides a maximum setpoint temperature for heat. The default setting is 35

, It can be changed 

between 30

to 35

 

3)  Select minimum temperature for cooling

 

This feature provides a minimum setpoint temperature for cooling. The default setting is 5

, It can be changed 

between 5

 to 20

   

4)  Memorize option before power loss

 

 

Using  

 & 

  button to select between “rE” and “rd”.    “rE” means the thermostat will Memorize its ON or 

OFF status before power loss. After power supply comes to normal again, the thermostat will remain ON or OFF 

according to what it is before power loss. “rd” means no matter the thermostat is switched on or off before power 

loss, after the power supply comes to normal again the thermostat will keep power off 

5)  Second stage fast or slow 

Select FA to start 2nd stage immediately when the set point is manually raised more than 2

 in  HEAT or 

lowered more than 2

  in COOL from room temperature . Select SL, the second stage will delay approximately 15 

minutes before starting. 

6) 

Display backlight option

 

Select 1 the light will be on when any button of the thermostat is touched. Select 2 the display will keep the light 

on continuously. Select 3 the display will keep the light off continuously Factory default is 1

 

7)  Fan option in heating mode 

       

If your system requires the thermostat to turn on the fan on a call for heat, select

 On.

 If your system 

does not require the thermostat to energize the fan on a call for heat such as fossil fuel (gas, oil, etc.), forced 

air system as well as hydraulic heating system, select

 Off. 

8) 

Minimum

 compressor off-time cycle setting 

To protect compressor from short cycling, you can select compressor off-time cycle, 3 means off-time cycle is 3 

minutes, 5 means off-time cycle is 5 minutes. When the thermostat compressor time delay occurs it will flash Cool 

on display for the time you have selected. Select 0 means you have canceled the function.

 

 

 

 

4